Patch G33 misuse of PROBE_MANUALLY

This commit is contained in:
Scott Lahteine 2017-11-07 19:47:45 -06:00
parent 69a7d4e0a5
commit 1d0739d6d1
6 changed files with 656 additions and 661 deletions

View File

@ -453,13 +453,6 @@
*/
#define HAS_Z_SERVO_ENDSTOP (defined(Z_ENDSTOP_SERVO_NR) && Z_ENDSTOP_SERVO_NR >= 0)
/**
* UBL has its own manual probing, so this just causes trouble.
*/
#if ENABLED(AUTO_BED_LEVELING_UBL)
#undef PROBE_MANUALLY
#endif
/**
* Set a flag for any enabled probe
*/

View File

@ -1062,11 +1062,6 @@
// Add commands that need sub-codes to this list
#define USE_GCODE_SUBCODES ENABLED(G38_PROBE_TARGET) || ENABLED(CNC_COORDINATE_SYSTEMS)
// MESH_BED_LEVELING overrides PROBE_MANUALLY
#if ENABLED(MESH_BED_LEVELING)
#undef PROBE_MANUALLY
#endif
// Parking Extruder
#if ENABLED(PARKING_EXTRUDER)
#ifndef PARKING_EXTRUDER_GRAB_DISTANCE

File diff suppressed because it is too large Load Diff

View File

@ -567,10 +567,8 @@ static_assert(1 >= 0
#error "You probably want to use Max Endstops for DELTA!"
#elif ENABLED(ENABLE_LEVELING_FADE_HEIGHT) && DISABLED(AUTO_BED_LEVELING_BILINEAR) && !UBL_DELTA
#error "ENABLE_LEVELING_FADE_HEIGHT on DELTA requires AUTO_BED_LEVELING_BILINEAR or AUTO_BED_LEVELING_UBL."
#elif ENABLED(DELTA_AUTO_CALIBRATION) && !PROBE_SELECTED
#error "DELTA_AUTO_CALIBRATION requires a probe: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, Z Servo."
#elif ENABLED(DELTA_AUTO_CALIBRATION) && ENABLED(PROBE_MANUALLY) && DISABLED(ULTIPANEL)
#error "DELTA_AUTO_CALIBRATION requires an LCD controller with PROBE_MANUALLY."
#elif ENABLED(DELTA_AUTO_CALIBRATION) && !(HAS_BED_PROBE || ENABLED(ULTIPANEL))
#error "DELTA_AUTO_CALIBRATION requires either a probe or an LCD Controller."
#elif ABL_GRID
#if (GRID_MAX_POINTS_X & 1) == 0 || (GRID_MAX_POINTS_Y & 1) == 0
#error "DELTA requires GRID_MAX_POINTS_X and GRID_MAX_POINTS_Y to be odd numbers."
@ -612,7 +610,7 @@ static_assert(1 >= 0
, "Please enable only one probe option: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
);
#if PROBE_SELECTED
#if HAS_BED_PROBE
/**
* Z_PROBE_SLED is incompatible with DELTA
@ -660,14 +658,14 @@ static_assert(1 >= 0
#if !HAS_Z_MIN_PROBE_PIN
#error "Z_MIN_PROBE_ENDSTOP requires the Z_MIN_PROBE_PIN to be defined."
#endif
#elif DISABLED(PROBE_MANUALLY)
#else
#error "You must enable either Z_MIN_PROBE_ENDSTOP or Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use a probe."
#endif
/**
* Make sure Z raise values are set
*/
#if !defined(Z_CLEARANCE_DEPLOY_PROBE)
#ifndef Z_CLEARANCE_DEPLOY_PROBE
#error "You must define Z_CLEARANCE_DEPLOY_PROBE in your configuration."
#elif !defined(Z_CLEARANCE_BETWEEN_PROBES)
#error "You must define Z_CLEARANCE_BETWEEN_PROBES in your configuration."
@ -682,14 +680,14 @@ static_assert(1 >= 0
/**
* Require some kind of probe for bed leveling and probe testing
*/
#if OLDSCHOOL_ABL
#if OLDSCHOOL_ABL && !PROBE_SELECTED
#error "Auto Bed Leveling requires one of these: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or a Z Servo."
#endif
#endif
#if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
#error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
#endif
#if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST) && !HAS_BED_PROBE
#error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
#endif
/**
@ -724,6 +722,9 @@ static_assert(1 >= 0
* Unified Bed Leveling
*/
// Hide PROBE_MANUALLY from the rest of the code
#undef PROBE_MANUALLY
#if IS_SCARA
#error "AUTO_BED_LEVELING_UBL does not yet support SCARA printers."
#elif DISABLED(EEPROM_SETTINGS)
@ -739,7 +740,7 @@ static_assert(1 >= 0
static_assert(WITHIN(UBL_PROBE_PT_3_Y, MIN_PROBE_Y, MAX_PROBE_Y), "UBL_PROBE_PT_3_Y can't be reached by the Z probe.");
#endif
#elif HAS_ABL
#elif OLDSCHOOL_ABL
/**
* Auto Bed Leveling
@ -788,6 +789,9 @@ static_assert(1 >= 0
#elif ENABLED(MESH_BED_LEVELING)
// Hide PROBE_MANUALLY from the rest of the code
#undef PROBE_MANUALLY
/**
* Mesh Bed Leveling
*/
@ -806,8 +810,8 @@ static_assert(1 >= 0
#if ENABLED(LCD_BED_LEVELING)
#if DISABLED(ULTIPANEL)
#error "LCD_BED_LEVELING requires an LCD controller."
#elif DISABLED(MESH_BED_LEVELING) && !(HAS_ABL && ENABLED(PROBE_MANUALLY))
#error "LCD_BED_LEVELING requires MESH_BED_LEVELING or PROBE_MANUALLY with auto bed leveling enabled."
#elif !(ENABLED(MESH_BED_LEVELING) || (OLDSCHOOL_ABL && ENABLED(PROBE_MANUALLY)))
#error "LCD_BED_LEVELING requires MESH_BED_LEVELING or ABL with PROBE_MANUALLY."
#endif
#endif

View File

@ -2682,26 +2682,9 @@ void kill_screen(const char* lcd_msg) {
float move_menu_scale;
#if ENABLED(DELTA_CALIBRATION_MENU)
#if ENABLED(DELTA_CALIBRATION_MENU) || (ENABLED(DELTA_AUTO_CALIBRATION) && !HAS_BED_PROBE)
void lcd_move_z();
void lcd_delta_calibrate_menu();
void _lcd_calibrate_homing() {
if (lcdDrawUpdate) lcd_implementation_drawmenu_static(LCD_HEIGHT >= 4 ? 1 : 0, PSTR(MSG_LEVEL_BED_HOMING));
lcdDrawUpdate = LCDVIEW_CALL_REDRAW_NEXT;
if (axis_homed[X_AXIS] && axis_homed[Y_AXIS] && axis_homed[Z_AXIS])
lcd_goto_previous_menu();
}
void _lcd_delta_calibrate_home() {
#if HAS_LEVELING
reset_bed_level(); // After calibration bed-level data is no longer valid
#endif
enqueue_and_echo_commands_P(PSTR("G28"));
lcd_goto_screen(_lcd_calibrate_homing);
}
void _man_probe_pt(const float rx, const float ry) {
#if HAS_LEVELING
@ -2719,6 +2702,10 @@ void kill_screen(const char* lcd_msg) {
lcd_goto_screen(lcd_move_z);
}
#endif // DELTA_CALIBRATION_MENU || (DELTA_AUTO_CALIBRATION && !HAS_BED_PROBE)
#if ENABLED(DELTA_AUTO_CALIBRATION) && !HAS_BED_PROBE
float lcd_probe_pt(const float &rx, const float &ry) {
_man_probe_pt(rx, ry);
KEEPALIVE_STATE(PAUSED_FOR_USER);
@ -2730,6 +2717,26 @@ void kill_screen(const char* lcd_msg) {
return current_position[Z_AXIS];
}
#endif // DELTA_AUTO_CALIBRATION && !HAS_BED_PROBE
#if ENABLED(DELTA_CALIBRATION_MENU)
void _lcd_calibrate_homing() {
if (lcdDrawUpdate) lcd_implementation_drawmenu_static(LCD_HEIGHT >= 4 ? 1 : 0, PSTR(MSG_LEVEL_BED_HOMING));
lcdDrawUpdate = LCDVIEW_CALL_REDRAW_NEXT;
if (axis_homed[X_AXIS] && axis_homed[Y_AXIS] && axis_homed[Z_AXIS])
lcd_goto_previous_menu();
}
void _lcd_delta_calibrate_home() {
#if HAS_LEVELING
reset_bed_level(); // After calibration bed-level data is no longer valid
#endif
enqueue_and_echo_commands_P(PSTR("G28"));
lcd_goto_screen(_lcd_calibrate_homing);
}
void _goto_tower_x() { _man_probe_pt(cos(RADIANS(210)) * delta_calibration_radius, sin(RADIANS(210)) * delta_calibration_radius); }
void _goto_tower_y() { _man_probe_pt(cos(RADIANS(330)) * delta_calibration_radius, sin(RADIANS(330)) * delta_calibration_radius); }
void _goto_tower_z() { _man_probe_pt(cos(RADIANS( 90)) * delta_calibration_radius, sin(RADIANS( 90)) * delta_calibration_radius); }

View File

@ -201,7 +201,7 @@ void lcd_reset_status();
float lcd_z_offset_edit();
#endif
#if ENABLED(DELTA_CALIBRATION_MENU)
#if ENABLED(DELTA_AUTO_CALIBRATION) && !HAS_BED_PROBE
float lcd_probe_pt(const float &rx, const float &ry);
#endif