Tested May 19 - It works! Verified with separate thermocouple TM-902C also.

This commit is contained in:
linagee 2012-05-20 04:13:29 -06:00
parent 4c37d0d9f1
commit dd9144994e

View File

@ -337,7 +337,6 @@ const short temptable_7[][2] PROGMEM = {
#if (THERMISTORHEATER_0 == 8) || (THERMISTORHEATER_1 == 8) || (THERMISTORHEATER_2 == 8) || (THERMISTORBED == 8)
// 100k EPCOS (WITH 1kohm RESISTOR FOR PULLUP, R9/R10 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
// Advantage: Twice the resolution and better linearity from 150C to 200C
// Experimental - untested
const short temptable_8[][2] PROGMEM = {
{190*OVERSAMPLENR, 250},
{203*OVERSAMPLENR, 245},