Commit Graph

770 Commits

Author SHA1 Message Date
AnHardt
051325ccd7 Introduce axis_homed
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:28 +01:00
Scott Lahteine
6a4f06d35d Fix GCode handling of spaces between command letter and first digit 2016-02-26 18:42:59 -08:00
CONSULitAS
ea8409ad5d Fix: current_command_args contains command
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.

see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on

Greetings and welcome back

Jochen
2016-02-24 09:35:04 +01:00
Scott Lahteine
e1beaf61eb Merge pull request #2985 from AnHardt/adv-ok
Repair N in ADVANCED_OK
2016-02-18 17:06:26 -08:00
Scott Lahteine
0c9db67273 Merge pull request #2983 from AnHardt/ok-echo
Replace the "ok" in M280, M301, M304, M851 with output not including …
2016-02-17 19:09:41 -08:00
Scott Lahteine
8eaba020fb Merge pull request #2973 from thinkyhead/fix_splash_url
Remove references to marlinfirmware.org
2016-02-17 17:05:06 -08:00
Scott Lahteine
be691b51f1 Remove references to marlinfirmware.org
The domain is gone and doesn’t redirect, so for now show no URL on the boot screen.
2016-02-17 14:41:46 -08:00
Scott Lahteine
711e5db19a Tweak comment in process_next_command 2016-02-09 18:16:35 -08:00
Scott Lahteine
400e9329be Allow spaces after a code letter 2016-02-09 18:03:13 -08:00
Scott Lahteine
cdcb80f3c5 Allow no-space after initial command
Addresses issue #2715
2016-02-09 18:00:35 -08:00
AnHardt
6f473f7fc6 Repair N in ADVANCED_OK
Send the correct line number.
If no N was in the command - non't send an N.
2016-02-09 19:23:26 +01:00
AnHardt
efbd705eda Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
to avoid senting two "ok"s for a single g-code.

Doing the same for M105 would break the input filters of the hosts.
For M105 the other "ok" is omitted.
2016-02-09 13:36:03 +01:00
Richard Wackerbarth
f6950acb8e Residual unused variable — Backport 2015-12-10 19:48:08 -06:00
AnHardt
57da1b8497 Host parseble output for M109, M190 and M303
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
2015-12-07 15:37:53 -06:00
AnHardt
fcceb98191 Unglobalize no_wait_for_cooling 2015-12-07 15:34:26 -06:00
Richard Wackerbarth
e293ea57f0 Unbalanced brackets in setPwmFrequency
This is a back port of the correct in issue #248
2015-11-30 05:44:32 -06:00
Scott Lahteine
17c23bbaf3 Shorten gcode_M221 yet function the same 2015-11-12 00:03:22 -06:00
Scott Lahteine
c0e791dbe9 Only look for "N" line number as first parameter 2015-11-12 00:03:22 -06:00
Scott Lahteine
b4af4441c5 Clean up watchdog impl. 2015-11-12 00:03:22 -06:00
Scott Lahteine
9bdab4f3a8 Clean up "else" and other spacing 2015-11-12 00:03:21 -06:00
Richard Wackerbarth
25d636c9e0 Compiler issues (PR#2696) 2015-11-11 23:52:11 -06:00
Scott Lahteine
ba6a243197 DEBUG message has no parameter (PR#2671) 2015-10-03 22:03:03 -05:00
Scott Lahteine
0c7f7ebcfb Styling adjustments (PR#2668 & PR#2670)
Keep "astyled" reformatting
2015-10-03 22:02:45 -05:00
fmalpartida
0f149ea0c6 LCD home button causes repeated homing (PR#175)
Fix: increased debounce delay.
2015-09-14 06:31:49 -05:00
Scott Lahteine
b825567e0f Drop www. from marlinfirmware.org (PR#175) 2015-09-14 06:28:53 -05:00
Scott Lahteine
bc50db9cf6 Implement PID_ADD_EXTRUSION_RATE 2015-09-12 07:53:20 -05:00
Scott Lahteine
fabf3ae4a0 Add final Z raise after Delta probe 2015-09-12 07:23:24 -05:00
Shane Francis
4c8330c15c Trim Adjustments for Delta Configurations 2015-09-03 01:05:33 -05:00
Scott Lahteine
962120d1d2 Fix spacing in some conditional blocks 2015-08-27 20:59:09 -05:00
Richard Wackerbarth
20b4772155 Create DEBUG_LEVELING_FEATURE 2015-08-27 20:52:08 -05:00
Scott Lahteine
194f98ff95 Debug messages for homing and leveling 2015-08-27 20:52:08 -05:00
Richard Wackerbarth
6292d9e815 Rename ENABLE_AUTO_BED_LEVELING
With the introduction of the #if ENABLED(…)

reads better than
2015-08-27 20:52:08 -05:00
Christian Lefrançois
9897a9147c Update ABL comments (PR#95)
* Updates the auto bed leveling comments ONLY.
* Renames "Z probe" word usage in //comments and #errors properly.
2015-08-26 05:51:38 -05:00
Scott Lahteine
23d742bf06 Don't free the stack array plane_equation_coefficients (PR#83) 2015-08-16 06:53:24 -05:00
Scott Lahteine
e3b1e08777 Patch G30 to use raise_z_for_servo (PR#73) 2015-08-15 21:47:04 -05:00
Scott Lahteine
a1eb90d5c0 Save another 30 bytes in gcode_SET_Z_PROBE_OFFSET 2015-08-12 21:26:32 -05:00
Scott Lahteine
91122277f4 Reduce gcode_SET_Z_PROBE_OFFSET by 88 bytes 2015-08-12 21:26:25 -05:00
AnHardt
5707a2c3d5 indexindexIntoAB is only vald for !DELTA 2015-08-11 17:32:11 -05:00
AnHardt
d8860f9ad9 Alway end at the same point
Always end at [RIGHT_PROBE_BED_POSITION, BACK_PROBE_BED_POSITION]
Regardles the evennes of auto_bed_leveling_grid_points.
2015-08-11 17:32:11 -05:00
AnHardt
4ca8f4a9a7 Always zigzag
Use the shortest way between probing-points.
2015-08-11 17:32:11 -05:00
AnHardt
3d23424121 Add array indexIntoAB[xx][yy]
and use it.
2015-08-11 17:32:11 -05:00
AnHardt
e2d69f66b2 Make Z_PROBE a Z_MIN_PROBE (PR#65)
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.

Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX  check for the probe in update_endstops().

Using an delta related idea of @clefranc from #61,
extended to the general change for all setups.

Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
2015-08-11 14:41:36 -05:00
Richard Wackerbarth
9d8cc24abf Continue from the line following the M999 (PR#60)
If the printer is going to accept the M999,
then it should continue from that line number.
2015-08-08 08:08:02 -05:00
Scott Lahteine
46453905d6 Apply remaining ENABLED/DISABLED conditionals 2015-08-03 16:04:48 -05:00
Richard Wackerbarth
b227d8c128 Supply a VERSION in a short form for displays
The long descriptor will still be available in M115
2015-08-03 08:21:09 -05:00
AnHardt
4f46df5dab Make bootscreen configurable for the graphic displays
Saves about 473 byte of progmem and 28 bytes of RAM.
2015-08-03 07:13:00 -05:00
Scott Lahteine
b4abb0ae7f Apply ENABLED / DISABLED to Marlin core files (PR#2558) 2015-07-31 01:03:58 -05:00
Scott Lahteine
9d151bb61b servo_endstop_angles -> servo_endstop_angle 2015-07-30 23:35:57 -05:00
Scott Lahteine
1f63293624 servo_endstops -> servo_endstop_id 2015-07-30 23:35:57 -05:00
Scott Lahteine
ed4a6371ad Add HAS_SERVO_ENDSTOPS to simplify conditonals 2015-07-30 23:35:57 -05:00