Brian
faa270071d
Improve BLTOUCH_HEATERS_OFF functionality
...
- rename to PROBING_HEATERS_OFF
- move heater pausing functionality into thermalManager
- add variables, pause(), ispaused(), other functions
- add fan pausing functionality -> PROBING_FANS_OFF
- add probing_pause() wrapper
- move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
- example configs
2017-05-07 16:22:08 -04:00
Scott Lahteine
2c13922c46
Implement USE_CONTROLLER_FAN as a feature
2017-05-02 20:18:52 -05:00
Bob-the-Kuhn
7ce613db0a
Fix Conditionals test for endstop plug used by Z2 or probe.
2017-05-02 15:41:47 -05:00
Scott Lahteine
ed81e9b3d3
Adjust leveling conditionals
2017-05-01 16:46:48 -05:00
Scott Lahteine
1823a6ea29
Patch for missing DELTA_HEIGHT
2017-05-01 11:05:35 -05:00
Scott Lahteine
c2c9f01c8e
Patch newly-introduced bug in IS_Z2_OR_PROBE
2017-04-30 20:17:10 -05:00
Scott Lahteine
671a44b8aa
Merge pull request #6410 from teemuatlut/LVD-Delta
...
Delta auto-calibration updates
2017-04-30 16:39:51 -05:00
LVD-AC
585c00a728
Proposed changes
...
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
2017-04-29 18:53:14 +03:00
Scott Lahteine
baf3b91460
DELTA_TOWER_ANGLE_TRIM only needs AB
2017-04-29 15:29:49 +03:00
Bob-the-Kuhn
40089249c3
add PIN_EXISTS to HAS_xyz_MIN macro
2017-04-28 16:47:59 -05:00
LVD-AC
dcf30a69d6
Allowing #define DELTA_TOWER_ANGLE_TRIM[C_AXIS]
...
More consistent with M665 where C-value is allowed as well, then
normalized
2017-04-23 14:51:24 +03:00
LVD-AC
13c8493878
M665 rework and related issues (all delta's)
...
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration )
- M665 B also sets the radius for manual calibration menu
- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard
- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define
2017-04-21 11:58:39 +03:00
Scott Lahteine
24882adfbf
Allow NO_WORKSPACE_OFFSETS with DELTA_AUTO_CALIBRATION
...
- On `DELTA` the `M665 H` option supplants `M206`
- On `DELTA` `NO_WORKSPACE_OFFSETS` only reverts `G92` behavior
- Spawn 4 conditionals based on `NO_WORKSPACE_OFFSETS`
- Optimize coordinate space conversion for `DELTA` workspace
- To keep EEPROM version, retain `home_offset[XYZ]`, just ignore XY
2017-04-14 21:56:49 -05:00
LVD-AC
03bda24d19
Add delta auto-calibration and configuration for Flsun AC
2017-04-14 19:08:14 -05:00
Scott Lahteine
f4685c28b7
Reorder Conditionals_post.h and add comments
2017-04-14 18:18:21 -05:00
Scott Lahteine
0ac2b5c045
Additional 5 extruders support (solenoids, microstepping)
2017-04-14 18:18:20 -05:00
Jimmy Envall
f78d44e91a
Added support for delta tower angle corrections.
2017-04-08 21:13:44 -05:00
Scott Lahteine
2a84122edd
Configuration changes to support 5 extruders
2017-04-07 10:46:35 -05:00
Scott Lahteine
699310d1d2
Fix: Thermal runaway if nonexistent bed's temp is set
2017-04-02 11:48:10 -05:00
Scott Lahteine
9e22184936
Add a "manual" option for ABL
2017-03-31 11:50:18 -05:00
Scott Lahteine
b5711a99a2
Patches to bring UBL closer to compliance
2017-03-24 01:37:52 -05:00
Scott Lahteine
e244399766
Additional cleanup of UBL code
2017-03-22 20:51:10 -05:00
Scott Lahteine
cf94688925
Univeral Bed Leveling - configuration
2017-03-18 11:35:19 -05:00
Scott Lahteine
3e927ff204
Replace MBL Z hacking
2017-03-17 06:05:17 -05:00
Jimmy Envall
00b6b3da79
Added support for delta tower angle corrections.
2017-03-07 16:35:58 -06:00
Scott Lahteine
bfb0007573
Patch DISTINCT_E_FACTORS bug
2017-03-05 23:19:31 -06:00
Scott Lahteine
c759c26cca
Make LCD_TIMEOUT_TO_STATUS configurable
...
As suggested in
https://github.com/MarlinFirmware/Marlin/issues/5570#issuecomment-283059
065
2017-02-28 19:02:50 -06:00
Scott Lahteine
a561bd5e3a
New feature: SDCARD_SORT_ALPHA
2017-02-14 21:37:24 -06:00
Scott Lahteine
092e949b58
Merge pull request #5169 from thinkyhead/rc_core_inverted
...
Support for COREYX, COREZX, COREZY
2016-11-28 02:26:41 -06:00
Scott Lahteine
3c9a838651
Extended capabilities report in M115
2016-11-09 02:32:58 -06:00
Scott Lahteine
1864b282c5
Implement reversed CORE options
2016-11-05 23:47:51 -05:00
Stanley
ab3f966f5f
Case light G-code M355
...
implemented G-Code M355 into Marlin
2016-11-01 06:30:14 -05:00
Scott Lahteine
c34dbfb248
Merge pull request #5072 from thinkyhead/rc_preset_auto_fans
...
Add predefined AUTO_FAN_PINs to pins files
2016-10-27 17:12:11 -05:00
Scott Lahteine
9a23f73765
Don't trigger endstops that are actually Z2 or probe
2016-10-27 08:12:17 -05:00
Scott Lahteine
b6aa894893
Rename auto fan pins and add auto fan flags
2016-10-26 17:51:26 -05:00
esenapaj
70e287ca8c
Extend measuring range of thermocouple for MAX31855
2016-10-23 10:22:39 +09:00
Josef Pavlik
c2b51af3ba
fixed warning: ISO C does not permit named variadic macros
2016-10-22 11:12:29 -05:00
Scott Lahteine
48761f2021
Patch delta endstop adjustment config
2016-10-09 13:32:45 -05:00
Josef Pavlik
28d41b48e3
delta endstop adjustment configurable
2016-10-09 13:09:34 -05:00
Scott Lahteine
d066610514
Patch up bilinear_z_offset
2016-09-29 01:31:05 -05:00
Scott Lahteine
ea0dbee3c9
Enable ABL by type, support bilinear on cartesian
2016-09-25 23:35:37 -05:00
Scott Lahteine
5fff8d148b
Clean up digital pots and microsteps
2016-09-25 11:16:22 -05:00
Scott Lahteine
eabff30e75
Improve MINIMUM_STEPPER_PULSE
2016-09-24 02:23:43 -05:00
Scott Lahteine
01f1028510
Try on "CLEARANCE" for size
2016-09-20 18:29:49 -05:00
Scott Lahteine
0e7d638a7a
Revert to Probe Raise rather than Probe Height
2016-09-20 18:29:49 -05:00
Scott Lahteine
7ae351c92f
Merge pull request #4842 from thinkyhead/rc_DISABLE_Z_MIN_PROBE_ENDSTOP_whassup
...
Drop DISABLE_Z_MIN_PROBE_ENDSTOP, clean up probe config
2016-09-20 12:16:51 -05:00
Scott Lahteine
e9ce42353e
Patch G29 for 3-point leveling
2016-09-20 04:46:41 -05:00
Scott Lahteine
e05af606a8
Clean up probe config options
2016-09-19 00:26:16 -05:00
Scott Lahteine
153e240cdd
Probe conditionals to Conditionals_LCD.h
2016-09-19 00:25:53 -05:00
Scott Lahteine
c4dcfa254e
Allow override of Z_ENDSTOP_SERVO_NR with BLTOUCH
2016-09-18 22:00:32 -05:00
Scott Lahteine
77639672d7
Move NONLINEAR bed leveling to planner
...
This is in advance of moving non-linear bed leveling to the planner
class.
2016-09-18 13:50:38 -05:00
Scott Lahteine
6ab54c60b1
Add conditionals for kinematics, leveling
2016-09-13 03:32:59 -05:00
Scott Lahteine
9248cfb0ad
Bed leveling that accounts for home XYZ
2016-09-10 13:47:21 -05:00
Scott Lahteine
b2e5ec85d7
Add [XYZ]_CENTER conditionals
2016-08-30 14:15:41 -05:00
Scott Lahteine
7e20448a2d
Add HOMING_Z_WITH_PROBE conditional
2016-08-30 13:29:26 -05:00
Scott Lahteine
1968983f35
Move PROBE_SELECTED to an earlier point
2016-08-25 20:59:44 -05:00
Scott Lahteine
01d4703429
PREVENT_DANGEROUS_EXTRUDE => PREVENT_COLD_EXTRUSION
...
Also improve the documentation of this and related options, and set
EXTRUDE_MINTEMP to 170 everywhere.
2016-08-20 23:35:27 -05:00
Scott Lahteine
7272ec5608
Update HAS_FAN flags for 4 auto fans
2016-08-13 20:05:32 -07:00
Scott Lahteine
7b21811a9a
Flags for matching auto-fans
2016-08-13 20:05:32 -07:00
Scott Lahteine
a36a168af2
Use the truly configured middle on Delta
2016-08-10 00:03:22 -07:00
Scott Lahteine
3a56836ead
Always disable SLOWDOWN for DELTA/SCARA
2016-08-08 18:06:46 -07:00
Scott Lahteine
462e189edd
Move pullups after Z_DUAL_ENDSTOPS block
2016-08-07 17:43:02 -07:00
Scott Lahteine
5fca110e0d
Fix Z_DUAL_ENDSTOPS with MIN homing
2016-08-07 17:08:41 -07:00
Scott Lahteine
938e6d15c4
Patch up some flaws, here and there
2016-08-05 08:17:37 -07:00
Scott Lahteine
7e2bd9a233
Z_RAISE_PROBE_* => Z_PROBE_*_HEIGHT
2016-08-03 21:18:38 -07:00
Scott Lahteine
cebd2bfff0
Auto-select power plugs for RAMPS derivatives
2016-08-02 11:59:25 -07:00
esenapaj
b8c112c490
Fix for PR #4453 (Improved MANUAL_[XYZ]_HOME_POS)
2016-07-30 19:37:43 +09:00
Scott Lahteine
696b63e300
Specify manual-movable E axes by extruder type
2016-07-30 00:36:48 -07:00
Scott Lahteine
ea5ac94804
Improved MANUAL_[XYZ]_HOME_POS
...
No need for `MANUAL_HOME_POSITIONS`. Just set each one as-needed to
override the automatic behavior.
2016-07-28 19:51:48 -07:00
Scott Lahteine
5367d56f87
Merge pull request #4434 from thinkyhead/rc_delta_safe_homing
...
DELTA should ignore Z_SAFE_HOMING
2016-07-27 23:41:52 -07:00
Scott Lahteine
2525528fb2
DELTA should ignore Z_SAFE_HOMING
2016-07-27 23:25:56 -07:00
Scott Lahteine
8953e3e984
Allow Z_SAFE_HOMING without a probe
2016-07-27 04:33:56 -07:00
Scott Lahteine
7e70a0b05d
Move pins / Arduino includes to MarlinConfig.h
2016-07-26 12:37:14 -07:00
Scott Lahteine
8a44928df3
Make Conditionals.h a catch-all for old configs
2016-07-26 12:19:50 -07:00