Implemented synchronization message output for NanoDLP printers (nanodlp.com).
If optional feature is enabled in `Configuration_adv.h`, Marlin will ouput "Z_move_comp" string to serial after completing any G0/G1 Z-axis movements. This feature patched on previous versions(1.0) is used by NanoDLP to synchronize Z-axis movement with projector exposure in DLP stereolithography printers.
* Fix thermal protection documentation.
Even before the recent thermal protection changes, the documentation of
the thermal protection feature in the config files did not match the
implementation. I fixed the documentation and reconciled the M303
implementation with the documentation.
* Applied documentation changes to sample config files
* Renamed hysteresis to watch_temp_increase
* Added gcodes back into documentation.
* Initial conflict resolution
All previous items resolved:
- Use of ELAPSED() on timer code
- Switch to use of defer_return_to_status=true as much as possible
- Update & Clean Up of Max7219 routines
* Resolve non-SD case in ultralcd.cpp
Ideally, it should be calculated based on Z steps per unit so that each
babystep corresponds to around 0.025mm. Smaller than this is largely
insignificant for typical layer heights.
* Add MAX7219_DEBUG to Travis CI testing
* Tweak config and use standard pin naming for MAX7219_DEBUG
* MAX7219: Apply coding standards, use macros, etc.
* Make code work...
* Add Max7219 LED Matrix Debug Support
The Max7219 8x8 LED Matrix's are very helpful for debugging new code.
And for that matter, just trying to maximize printer settings without
causing stuttering.
The displays are very inexpensive (under $2.00 with shipping) and
provide a lot of help when trying to debug complicated code.
* Try to keep Makefile up to date.
==============================
Configuration_adv.h changes
==============================
add "live" LCD update
==============================
P & S version
==============================
final (hopefully) tested version
==============================
update M115 capabilities print
==============================
Menu changes portion of the requested changes
==============================
changed USEABLE_HARDWARE_PWM from a function to a series of macros
==============================
changes per review
The menu (commands / scripts) is configurable in `Configuration_adv.h`.
- Added conditionals.
- Changed script handling.
- Slimmed and working!
- Added Status message.
- Returning to lcd status screen now!
- Example Configs Updated.
- Cleanups by @thinkyhead
* Unify M600 and M125 pause features
* Cleanup per thinkyhead's comments
* Rename filament_change_menu_response to advanced_pause_menu_response
* Include HAS_BED_PROBE in QUIET_PROBING
* Update gMax example file
* is_idle() is out of scope without the braces
* Convert FT-i3-2020 to Advance Pause names...
* Allow pause even if not printing
- fix broken `M421` due to less-than-careful optimization
- add HOME_AFTER_DEACTIVATE define to advanced config so not everyone has to rehome after steppers are deactivated
- misc. cleanups (remove unused label, unused variables)