G26 uses logic that looks like:
```
ex = _GET_MESH_X(i + 1) - (SIZE_OF_INTERSECTION_CIRCLES - (SIZE_OF_CROSSHAIRS));
```
The Bi-Linear macros need parenthesis to work correctly.
Example Configuration.h files are not updated yet. You need to cross
your settings over to the default Configuration.h file in the \Marlin
directory. (UBL_G26_MESH_VALIDATION enablement has moved to a new
location in the file.)
* Unify M600 and M125 pause features
* Cleanup per thinkyhead's comments
* Rename filament_change_menu_response to advanced_pause_menu_response
* Include HAS_BED_PROBE in QUIET_PROBING
* Update gMax example file
* is_idle() is out of scope without the braces
* Convert FT-i3-2020 to Advance Pause names...
* Allow pause even if not printing
- rename to PROBING_HEATERS_OFF
- move heater pausing functionality into thermalManager
- add variables, pause(), ispaused(), other functions
- add fan pausing functionality -> PROBING_FANS_OFF
- add probing_pause() wrapper
- move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
- example configs
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration)
- M665 B also sets the radius for manual calibration menu
- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard
- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define
- On `DELTA` the `M665 H` option supplants `M206`
- On `DELTA` `NO_WORKSPACE_OFFSETS` only reverts `G92` behavior
- Spawn 4 conditionals based on `NO_WORKSPACE_OFFSETS`
- Optimize coordinate space conversion for `DELTA` workspace
- To keep EEPROM version, retain `home_offset[XYZ]`, just ignore XY