This is an initial cut for feedback.
Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?
Chamber temperatures are not reported on the LCD in any way.
When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.
As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
・More ANALOG NUMBERING to Analog Input
・Add comment header to all the section of all the pins files
・Sort sections as follows:
1. Some special definitions (USBCON, LARGE_FLASH, etc)
2. Servos
3. Limit Switches
4. Z Probe
5. Steppers
6. Temperature Sensors
7. Heaters / Fans
8. Misc. Functions
9. LCD / Controller
・Move MAX6675_SS into "Temperature Sensors" section
・Adjust spacing
Includes:
*firmware version / branch / date.
*extruder count
*board information (name, serial details, power supply type)
*thermistors (names, min/max temperatures)
*printer statistics (PRINTCOUNTER details)
Thanks to @thinkyhead for contributions.
- `SD_DETECT_PIN` replaces `SDCARDDETECT`
- `SD_DETECT_INVERTED` replaces `SDCARDDETECTINVERTED`
- Revise the description of `SD_DETECT_INVERTED`
- Add a note about the override of `SD_DETECT_INVERTED` in
`Conditionals.h`
- Reduce calls to millis()
- General cleanup of manage_heaters
- General cleanup of pid autotune
- Formatting here & there
- Macros to clean up and shrink ISR code (reduced by ~364 lines)