* Fix thermal protection documentation.
Even before the recent thermal protection changes, the documentation of
the thermal protection feature in the config files did not match the
implementation. I fixed the documentation and reconciled the M303
implementation with the documentation.
* Applied documentation changes to sample config files
* Renamed hysteresis to watch_temp_increase
* Added gcodes back into documentation.
* Initial conflict resolution
All previous items resolved:
- Use of ELAPSED() on timer code
- Switch to use of defer_return_to_status=true as much as possible
- Update & Clean Up of Max7219 routines
* Resolve non-SD case in ultralcd.cpp
Ideally, it should be calculated based on Z steps per unit so that each
babystep corresponds to around 0.025mm. Smaller than this is largely
insignificant for typical layer heights.
* Add MAX7219_DEBUG to Travis CI testing
* Tweak config and use standard pin naming for MAX7219_DEBUG
* MAX7219: Apply coding standards, use macros, etc.
* Make code work...
* Add Max7219 LED Matrix Debug Support
The Max7219 8x8 LED Matrix's are very helpful for debugging new code.
And for that matter, just trying to maximize printer settings without
causing stuttering.
The displays are very inexpensive (under $2.00 with shipping) and
provide a lot of help when trying to debug complicated code.
* Try to keep Makefile up to date.
==============================
Configuration_adv.h changes
==============================
add "live" LCD update
==============================
P & S version
==============================
final (hopefully) tested version
==============================
update M115 capabilities print
==============================
Menu changes portion of the requested changes
==============================
changed USEABLE_HARDWARE_PWM from a function to a series of macros
==============================
changes per review
The menu (commands / scripts) is configurable in `Configuration_adv.h`.
- Added conditionals.
- Changed script handling.
- Slimmed and working!
- Added Status message.
- Returning to lcd status screen now!
- Example Configs Updated.
- Cleanups by @thinkyhead
* Unify M600 and M125 pause features
* Cleanup per thinkyhead's comments
* Rename filament_change_menu_response to advanced_pause_menu_response
* Include HAS_BED_PROBE in QUIET_PROBING
* Update gMax example file
* is_idle() is out of scope without the braces
* Convert FT-i3-2020 to Advance Pause names...
* Allow pause even if not printing
- fix broken `M421` due to less-than-careful optimization
- add HOME_AFTER_DEACTIVATE define to advanced config so not everyone has to rehome after steppers are deactivated
- misc. cleanups (remove unused label, unused variables)
# This is the 1st commit message:
MCP4728 consistency & fix ultralcd.cpp
The MCP4728 DAC controls the stepper motor current strenth on the
PRINTRBOARD Rev F and RIGIDBOARD V2 boards.
PR #5792 on 9 FEB 2017 implemented default drive percentages but only on
the RIGIDBOARD V2.
This change moves the default settings to Configuration_adv.h.
Also, ultralcd.cpp won't compile because of a type def conflict.
Changed it to match the one in stepper_dac.cpp
===========================================================
reword stepper curent section for clarity
===========================================================
change name & improve comments
===========================================================
changed name from A4JP to SCOOVO_X9H per PR #6139
# This is the commit message #2:
fix typo
The offset for Z_DUAL_ENDSTOP (z_endstop_adj) is already in Marlin.
This PR just makes it a configuration item.
z_endstop_adj is initialized in two places so both had to be modified.
Made the double touch portion a conditional compile based on the
PROBE_DOUBLE_TOUCH flag.
==============================================
Bugfix
The current G38 only stopped a move if it involved the Z axis.
Moved all the G38 code to it's own section and put it where it would
always be executed no matter what axis was moving or if the endstop was
enabled.
Also added a comment to configuration_adv to alert the user the double
tap had to be turned on.
==============================================
Change G38 back to using Z_MIN_PROBE
There's no Z_MIN endstop if Z_DUAL_ENDSTOPS is enabled and you have them
set to the top of the gantry.
G38 started out as using the Z_MIN_PROBE pin. I don't remember why we
changed it to the Z_MIN endstop.
The target here is to update the screens of graphical and char base
displays as fast as possible, without draining the planner buffer too much.
For that measure the time it takes to draw and transfer one
(partial) screen to the display. Build a max. value from that.
Because ther can be large differences, depending on how much the display
updates are interrupted, the max value is decreased by one ms/s. This way
it can shrink again.
On the other side we keep track on how much time it takes to empty the
planner buffer.
Now we draw the next (partial) display update only then, when we do not
drain the planner buffer to much. We draw only when the time in the
buffer is two times larger than a update takes, or the buffer is empty anyway.
When we have begun to draw a screen we do not wait until the next 100ms
time slot comes. We draw the next partial screen as fast as possible, but
give the system a chance to refill the buffers a bit.
When we see, during drawing a screen, the screen contend has changed,
we stop the current draw and begin to draw the new content from the top.