Commit Graph

219 Commits

Author SHA1 Message Date
Scott Lahteine
f882355994 Merge pull request #5318 from Sebastianv650/Account_for_LCD_improvements
Account for LCD improvements in ENSURE_SMOOTH_MOVES
2016-12-05 11:23:58 -06:00
Scott Lahteine
d5bf1684fe Implement as optional feature LCD_DECIMAL_SMALL_XY
And reduce the function size to simplify
2016-12-05 09:26:05 -06:00
Scott Lahteine
f60b4f8659 Allow case light pin to be active low 2016-12-01 23:32:34 -06:00
Sebastianv650
f62f4006af Account for LCD improvements in ENSURE_SMOOTH_MOVES
.. and give the hint to try lower values if possible.
2016-11-28 17:44:19 +01:00
Scott Lahteine
5460a529da Add option DOGM_SPI_DELAY_US 2016-11-26 06:53:52 -06:00
esenapaj
ef97645002 Follow-up the PR #5255 (Case light menu (3rd attempt)) 2016-11-24 19:42:05 +09:00
Scott Lahteine
4e4f37b6c2 Code formatting for TMC and L6470 config options 2016-11-21 00:52:18 -06:00
Scott Lahteine
bf5f5f44cc Make TMC2130 init code auto-configure
Simply apply enabled settings instead of requiring users to edit
stepper_indirection.cpp
2016-11-21 00:52:17 -06:00
Moritz
d67c1d825f Add TMC2130 support 2016-11-21 00:17:45 -06:00
Scott Lahteine
072541f286 Update ENSURE_SMOOTH_MOVES in all configs 2016-11-19 01:28:47 -06:00
Sebastianv650
de89dc9f04 Ensure smooth print moves even with LCD enabled
lcd_update can take so much time that the block buffer gets drained if
there are only short segments. This leads to jerky printer movements for
example in circles and a bad print quality.

This change implements a simple check: Only if the block currently
executed is long enough, run lcd_update.
This also means the printer will not show actual values on the LCD nor
will it respond to buttons pressed. A option that keeps the menu
accessible is also available.
Aditionaly, slow down if a block would be so fast that adding a new
block to the buffer would take more time. In this case, the buffer would
drain until it's empty in worst case.
2016-11-19 01:28:47 -06:00
Scott Lahteine
60cc9342a4 Merge pull request #5188 from thinkyhead/rc_extended_host_support
Extended host support: M155 Auto temp report, M115 capabilities
2016-11-12 15:38:06 -06:00
Scott Lahteine
3c9a838651 Extended capabilities report in M115 2016-11-09 02:32:58 -06:00
Scott Lahteine
68b866b5dd Add M155 - Auto-report temperature with interval 2016-11-09 02:32:58 -06:00
Scott Lahteine
75bfde9945 M155=>M260, M156=>M261 2016-11-08 17:54:54 -06:00
esenapaj
2ae72b0491 Follow up the PR #5167 (Add Turkish Language) again, etc
・Update forgotten K8400\Dual-head\Configuration.h
・Adjust spacing
2016-11-09 06:31:21 +09:00
Scott Lahteine
2495ab7af2 Make dual_x_carriage_mode an enumeration 2016-11-02 21:38:49 -05:00
Stanley
ab3f966f5f Case light G-code M355
implemented G-Code M355 into Marlin
2016-11-01 06:30:14 -05:00
Scott Lahteine
b6aa894893 Rename auto fan pins and add auto fan flags 2016-10-26 17:51:26 -05:00
Scott Lahteine
b9109b2875 Improve LIN_ADVANCE commentary (all configs) 2016-10-22 05:03:09 -05:00
Sebastianv650
599649e45d Add formula for LIN_ADVANCE_K
With this formula, a start value for K for further fine-calibration can be calculated.
2016-10-22 04:54:59 -05:00
Scott Lahteine
a0df34fd4c Add PINS_DEBUGGING advanced config option 2016-10-07 14:20:13 -05:00
Scott Lahteine
919fe3e4b8 Rename feature to G38_PROBE_TARGET 2016-10-01 05:00:53 -05:00
Scott Lahteine
a2864ab7fe Patched up, cleaned up 2016-10-01 05:00:53 -05:00
Bob-the-Kuhn
2911aa7ffa code changes to implement G38 commands
1) modified 3 code files
Marlin.h
Marlin_main.cpp
endstops.cpp

2) modified config files so I could test on my machine

Testing was done on an AzteegX3pro based machine.

The probe was hooked to the Z_MIN endstop.

My controller doesn't have a dedicated Z_PROBE input so I couldn't test
that functionality.

Verified that a large file (without any G38 commands) executed the same
before and after the changes.

Verified that the head moves as expected when G38.2 and G38.3 commands
are issued. Single & multiple axis moves were tested along with + and -
directions.

Code was added to the main ISR. In normal operation only one extra IF
statement is evaluated. I didn't notice any performance degradation
because of the added code.

The G38 commands are expected to be issued manually by the operator
during machine setup. The G38 commands wait until the machine is idle
before proceeding. That way the other commands are minimally impacted
by the extra ISR overhead when a G38 command is in the queue.

The G38 commands are very similar to the G28 commands except 1) only the
Z_PROBE is used and movement can be in the + or - direction.

See issue 4677 for a discussion on adding G38 commands to Marlin.
Feature request: add ability to use G38.2 command (CNC)
MarlinFirmware/Marlin#4677
2016-10-01 05:00:53 -05:00
esenapaj
92c03a44a9 Fix the PR #4899 (ABL: Enable by type. Bilinear for all.) etc.
About Configuration.h:
・Fix the PR #4899 (ABL: Enable by type. Bilinear for all.)
Remove Duplicated contents

・Fix the PR #4305 (Custom boot screen feature improvement)
Revert from "during boot" to "during bootup" in all the example
Configuration.h

・Fix the PR #4207 (Clean up, simplify and generalize the Allen-key-probe
code.)
Resolve and relocate the duplicated definitions in Z_PROBE_ALLEN_KEY
section

・Follow-up the PR #4805 (Additional documentation of Configuration.h)
Add forgotten changes to all the example Configuration.h

Adjust spacing

About Configuration_adv.h:
Add missing description of SLOWDOWN for DELTA

Adjust spacing
2016-09-28 14:14:04 -05:00
Scott Lahteine
9b0931ef74 Apply fixed EXTRUDER_RUNOUT_PREVENT 2016-09-13 03:33:04 -05:00
Scott Lahteine
759234af60 MINIMUM_STEPPER_PULSE option 2016-08-27 23:58:40 -05:00
Scott Lahteine
ab59280075 MIN_SEGMENTS_FOR_MOVE => MIN_STEPS_PER_SEGMENT
Follow-up to #4666
2016-08-21 08:56:03 -05:00
Scott Lahteine
374f8d2014 dropsegments => MIN_SEGMENTS_FOR_MOVE 2016-08-20 18:52:15 -05:00
Scott Lahteine
d63b8e2b2b Additional details for I2C_SLAVE_ADDRESS 2016-08-15 19:27:53 -07:00
Scott Lahteine
a99ecf71d8 Add support for i2c slave address 2016-08-10 23:30:35 -07:00
Scott Lahteine
63fd1f49a6 PID_EXTRUSION_SCALING, disabled by default 2016-07-31 17:49:34 -07:00
Scott Lahteine
c6226bb0aa Unify config in a single include without nested includes 2016-07-25 23:04:19 -07:00
Scott Lahteine
93ea281061 Split up Conditionals.h into two files
Rather than include twice, which is tricky but may confuse
2016-07-25 20:30:45 -07:00
Scott Lahteine
fcc39e2b5f Clean up Transfer Buffer Size comment 2016-07-25 12:54:55 -07:00
Scott Lahteine
91777dd76c Add DUAL_NOZZLE_DUPLICATION_MODE option 2016-07-22 16:22:56 -07:00
Scott Lahteine
0fcd3706dd Replace ENDSTOPS_ONLY_FOR_HOMING with ENDSTOPS_ALWAYS_ON_DEFAULT 2016-07-17 13:35:21 -07:00
Scott Lahteine
91bd6eade7 X_DUAL_STEPPER_DRIVERS configuration option 2016-07-11 10:22:19 -07:00
Scott Lahteine
182c8d7f8f Dyze High Temp Thermistor Support 2016-07-10 17:59:05 -07:00
AnHardt
4b44a23a36 Add TX-buffer for MarlinSerial
Similar to the current Arduino HardwareSerial
but with max. 256 byte buffer-size.

Deactivated by default.

The boards with AT90USB processor (USBCON) already use a TX-buffer.
2016-07-08 17:25:21 +02:00
AnHardt
a129078927 Add an emergency-command parser to MarlinSerial (supporting M108)
Add an emergency-command parser to MarlinSerial's RX interrupt.

The parser tries to find and execute M108,M112,M410 before the commands disappear in the RX-buffer.

To avoid false positives for M117, comments and commands followed by filenames (M23, M28, M30, M32, M33) are filtered.

This enables Marlin to receive and react on the Emergency command at all times - regardless of whether the buffers are full or not. It remains to convince hosts to send the commands. To inform the hosts about the new feature a new entry in the M115-report was made. "`EMERGENCY_CODES:M112,M108,M410;`".

The parser is fast. It only ever needs two switch decisions and one assignment of the new state for every character.

One problem remains. If the host has sent an incomplete line before sending an emergency command the emergency command could be omitted when the parser is in `state_IGNORE`.
In that case the host should send "\ncommand\n"

Also introduces M108 to break the waiting for the heaters in M109, M190 and M303.

Rename `cancel_heatup` to `wait_for_heatup` to better see the purpose.
2016-07-07 16:37:22 -07:00
Petr Zahradnik
43ff0ce35f Rewritten FILAMENT_CHANGE_ENABLE feature 2016-07-02 15:34:33 -07:00
Anthony Birkett
7a377c1d75 Add "About Printer" information menu.
Includes:
  *firmware version / branch / date.
  *extruder count
  *board information (name, serial details, power supply type)
  *thermistors (names, min/max temperatures)
  *printer statistics (PRINTCOUNTER details)

Thanks to @thinkyhead for contributions.
2016-07-02 15:22:26 -07:00
Scott Lahteine
f84d85f761 Cleanup extruder runout configs 2016-06-30 01:40:41 -07:00
Scott Lahteine
40cd20a236 Fix comments on EXPERIMENTAL_I2CBUS 2016-06-21 17:58:44 -07:00
Scott Lahteine
eab44b30d4 Safety and serial sections 2016-06-17 15:19:43 -07:00
Scott Lahteine
f639044c24 Merge pull request #3609 from jbrazio/feature/config-version
Adds versioning for Configuration.h & Configuration_adv.h
2016-06-15 22:09:47 -07:00
João Brázio
8ccd97e7cc
Updated all example configuration files 2016-06-12 00:36:15 +01:00
João Brázio
de8108648f
Added a versioning system to the config files 2016-06-11 23:48:10 +01:00