Chamber vent/fan followup
This commit is contained in:
parent
f1e563d8cf
commit
2c6ec0c999
@ -1205,13 +1205,13 @@ void Temperature::manage_heater() {
|
|||||||
#if CHAMBER_FAN_MODE == 0
|
#if CHAMBER_FAN_MODE == 0
|
||||||
fan_chamber_pwm = CHAMBER_FAN_BASE
|
fan_chamber_pwm = CHAMBER_FAN_BASE
|
||||||
#elif CHAMBER_FAN_MODE == 1
|
#elif CHAMBER_FAN_MODE == 1
|
||||||
fan_chamber_pwm = temp_chamber.celsius > temp_chamber.target ? CHAMBER_FAN_BASE + ((temp_chamber.celsius - temp_chamber.target) * CHAMBER_FAN_FACTOR ) : 0;
|
fan_chamber_pwm = (temp_chamber.celsius > temp_chamber.target) ? (CHAMBER_FAN_BASE) + (CHAMBER_FAN_FACTOR) * (temp_chamber.celsius - temp_chamber.target) : 0;
|
||||||
#elif CHAMBER_FAN_MODE == 2
|
#elif CHAMBER_FAN_MODE == 2
|
||||||
fan_chamber_pwm = (CHAMBER_FAN_BASE) + (CHAMBER_FAN_FACTOR) * ABS(temp_chamber.celsius - temp_chamber.target);
|
fan_chamber_pwm = (CHAMBER_FAN_BASE) + (CHAMBER_FAN_FACTOR) * ABS(temp_chamber.celsius - temp_chamber.target);
|
||||||
if (temp_chamber.soft_pwm_amount)
|
if (temp_chamber.soft_pwm_amount)
|
||||||
fan_chamber_pwm += (CHAMBER_FAN_FACTOR) * 2;
|
fan_chamber_pwm += (CHAMBER_FAN_FACTOR) * 2;
|
||||||
#endif
|
#endif
|
||||||
fan_chamber_pwm = _MIN(225, fan_chamber_pwm);
|
NOMORE(fan_chamber_pwm, 225);
|
||||||
thermalManager.set_fan_speed(2, fan_chamber_pwm); // TODO: instead of fan 2, set to chamber fan
|
thermalManager.set_fan_speed(2, fan_chamber_pwm); // TODO: instead of fan 2, set to chamber fan
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
@ -1256,7 +1256,13 @@ void Temperature::manage_heater() {
|
|||||||
next_chamber_check_ms = ms + CHAMBER_CHECK_INTERVAL;
|
next_chamber_check_ms = ms + CHAMBER_CHECK_INTERVAL;
|
||||||
|
|
||||||
if (WITHIN(temp_chamber.celsius, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
|
if (WITHIN(temp_chamber.celsius, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
|
||||||
if (!flag_chamber_excess_heat){
|
if (flag_chamber_excess_heat) {
|
||||||
|
temp_chamber.soft_pwm_amount = 0;
|
||||||
|
#if ENABLED(CHAMBER_VENT)
|
||||||
|
if (!flag_chamber_off) MOVE_SERVO(CHAMBER_VENT_SERVO_NR, temp_chamber.celsius <= temp_chamber.target ? 0 : 90);
|
||||||
|
#endif
|
||||||
|
}
|
||||||
|
else {
|
||||||
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
|
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
|
||||||
if (temp_chamber.celsius >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS)
|
if (temp_chamber.celsius >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS)
|
||||||
temp_chamber.soft_pwm_amount = 0;
|
temp_chamber.soft_pwm_amount = 0;
|
||||||
@ -1269,12 +1275,6 @@ void Temperature::manage_heater() {
|
|||||||
if (!flag_chamber_off) MOVE_SERVO(CHAMBER_VENT_SERVO_NR, 0);
|
if (!flag_chamber_off) MOVE_SERVO(CHAMBER_VENT_SERVO_NR, 0);
|
||||||
#endif
|
#endif
|
||||||
}
|
}
|
||||||
else {
|
|
||||||
temp_chamber.soft_pwm_amount = 0;
|
|
||||||
#if ENABLED(CHAMBER_VENT)
|
|
||||||
if (!flag_chamber_off) MOVE_SERVO(CHAMBER_VENT_SERVO_NR, temp_chamber.celsius <= temp_chamber.target ? 0 : 90);
|
|
||||||
#endif
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
else {
|
else {
|
||||||
temp_chamber.soft_pwm_amount = 0;
|
temp_chamber.soft_pwm_amount = 0;
|
||||||
|
Loading…
Reference in New Issue
Block a user