M303 pid autotune cleanup, commentary
This commit is contained in:
parent
f968b41f63
commit
4af3d436b2
@ -26,7 +26,7 @@
|
||||
/**
|
||||
* M303: PID relay autotune
|
||||
*
|
||||
* S<temperature> sets the target temperature. (default 150C)
|
||||
* S<temperature> sets the target temperature. (default 150C / 70C)
|
||||
* E<extruder> (-1 for the bed) (default 0)
|
||||
* C<cycles>
|
||||
* U<bool> with a non-zero value will apply the result to current settings
|
||||
|
@ -219,8 +219,8 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
* Alternately heat and cool the nozzle, observing its behavior to
|
||||
* determine the best PID values to achieve a stable temperature.
|
||||
*/
|
||||
void Temperature::PID_autotune(const float temp, const int8_t hotend, const int8_t ncycles, const bool set_result/*=false*/) {
|
||||
float input = 0.0;
|
||||
void Temperature::PID_autotune(const float &target, const int8_t hotend, const int8_t ncycles, const bool set_result/*=false*/) {
|
||||
float current = 0.0;
|
||||
int cycles = 0;
|
||||
bool heating = true;
|
||||
|
||||
@ -232,34 +232,19 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
workKp = 0, workKi = 0, workKd = 0,
|
||||
max = 0, min = 10000;
|
||||
|
||||
#define HAS_TP_BED (ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED))
|
||||
#if HAS_TP_BED && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||
#define TV(B,H) (hotend < 0 ? (B) : (H))
|
||||
#elif HAS_TP_BED
|
||||
#define TV(B,H) (B)
|
||||
#else
|
||||
#define TV(B,H) (H)
|
||||
#endif
|
||||
|
||||
#if WATCH_THE_BED || WATCH_HOTENDS
|
||||
const float watch_temp_target = temp -
|
||||
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||
(hotend < 0 ? (WATCH_BED_TEMP_INCREASE + TEMP_BED_HYSTERESIS + 1) : (WATCH_TEMP_INCREASE + TEMP_HYSTERESIS + 1))
|
||||
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
||||
(WATCH_BED_TEMP_INCREASE + TEMP_BED_HYSTERESIS + 1)
|
||||
#else
|
||||
(WATCH_TEMP_INCREASE + TEMP_HYSTERESIS + 1)
|
||||
#endif
|
||||
;
|
||||
const int8_t watch_temp_period =
|
||||
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||
hotend < 0 ? WATCH_BED_TEMP_PERIOD : WATCH_TEMP_PERIOD
|
||||
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
||||
WATCH_BED_TEMP_PERIOD
|
||||
#else
|
||||
WATCH_TEMP_PERIOD
|
||||
#endif
|
||||
;
|
||||
const int8_t watch_temp_increase =
|
||||
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||
hotend < 0 ? WATCH_BED_TEMP_INCREASE : WATCH_TEMP_INCREASE
|
||||
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
||||
WATCH_BED_TEMP_INCREASE
|
||||
#else
|
||||
WATCH_TEMP_INCREASE
|
||||
#endif
|
||||
;
|
||||
const int8_t watch_temp_period = TV(WATCH_BED_TEMP_PERIOD, WATCH_TEMP_PERIOD),
|
||||
watch_temp_increase = TV(WATCH_BED_TEMP_INCREASE, WATCH_TEMP_INCREASE);
|
||||
const float watch_temp_target = target - float(watch_temp_increase + TV(TEMP_BED_HYSTERESIS, TEMP_HYSTERESIS) + 1);
|
||||
millis_t temp_change_ms = next_temp_ms + watch_temp_period * 1000UL;
|
||||
float next_watch_temp = 0.0;
|
||||
bool heated = false;
|
||||
@ -300,7 +285,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
soft_pwm_amount_bed = bias = d = (MAX_BED_POWER) >> 1;
|
||||
#endif
|
||||
|
||||
wait_for_heatup = true;
|
||||
wait_for_heatup = true; // Can be interrupted with M108
|
||||
|
||||
// PID Tuning loop
|
||||
while (wait_for_heatup) {
|
||||
@ -310,7 +295,8 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
if (temp_meas_ready) { // temp sample ready
|
||||
updateTemperaturesFromRawValues();
|
||||
|
||||
input =
|
||||
// Get the current temperature and constrain it
|
||||
current =
|
||||
#if HAS_PID_FOR_BOTH
|
||||
hotend < 0 ? current_temperature_bed : current_temperature[hotend]
|
||||
#elif ENABLED(PIDTEMP)
|
||||
@ -319,9 +305,8 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
current_temperature_bed
|
||||
#endif
|
||||
;
|
||||
|
||||
NOLESS(max, input);
|
||||
NOMORE(min, input);
|
||||
NOLESS(max, current);
|
||||
NOMORE(min, current);
|
||||
|
||||
#if HAS_AUTO_FAN
|
||||
if (ELAPSED(ms, next_auto_fan_check_ms)) {
|
||||
@ -330,7 +315,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
}
|
||||
#endif
|
||||
|
||||
if (heating && input > temp) {
|
||||
if (heating && current > target) {
|
||||
if (ELAPSED(ms, t2 + 5000UL)) {
|
||||
heating = false;
|
||||
#if HAS_PID_FOR_BOTH
|
||||
@ -345,11 +330,11 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
#endif
|
||||
t1 = ms;
|
||||
t_high = t1 - t2;
|
||||
max = temp;
|
||||
max = target;
|
||||
}
|
||||
}
|
||||
|
||||
if (!heating && input < temp) {
|
||||
if (!heating && current < target) {
|
||||
if (ELAPSED(ms, t1 + 5000UL)) {
|
||||
heating = true;
|
||||
t2 = ms;
|
||||
@ -373,7 +358,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
SERIAL_PROTOCOLPAIR(MSG_T_MIN, min);
|
||||
SERIAL_PROTOCOLPAIR(MSG_T_MAX, max);
|
||||
if (cycles > 2) {
|
||||
Ku = (4.0 * d) / (M_PI * (max - min) * 0.5); // i.e., CIRCLE_CIRC((max - min) * 0.25)
|
||||
Ku = (4.0 * d) / (M_PI * (max - min) * 0.5);
|
||||
Tu = ((float)(t_low + t_high) * 0.001);
|
||||
SERIAL_PROTOCOLPAIR(MSG_KU, Ku);
|
||||
SERIAL_PROTOCOLPAIR(MSG_TU, Tu);
|
||||
@ -413,41 +398,48 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||
soft_pwm_amount_bed = (bias + d) >> 1;
|
||||
#endif
|
||||
cycles++;
|
||||
min = temp;
|
||||
min = target;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// Did the temperature overshoot very far?
|
||||
#define MAX_OVERSHOOT_PID_AUTOTUNE 20
|
||||
if (input > temp + MAX_OVERSHOOT_PID_AUTOTUNE) {
|
||||
if (current > target + MAX_OVERSHOOT_PID_AUTOTUNE) {
|
||||
SERIAL_PROTOCOLLNPGM(MSG_PID_TEMP_TOO_HIGH);
|
||||
break;
|
||||
}
|
||||
// Every 2 seconds...
|
||||
|
||||
// Report heater states every 2 seconds
|
||||
if (ELAPSED(ms, next_temp_ms)) {
|
||||
#if HAS_TEMP_HOTEND || HAS_TEMP_BED
|
||||
print_heaterstates();
|
||||
SERIAL_EOL();
|
||||
#endif
|
||||
|
||||
next_temp_ms = ms + 2000UL;
|
||||
|
||||
// Make sure heating is actually working
|
||||
#if WATCH_THE_BED || WATCH_HOTENDS
|
||||
if (!heated && input > next_watch_temp) {
|
||||
if (input > watch_temp_target) heated = true;
|
||||
next_watch_temp = input + watch_temp_increase;
|
||||
temp_change_ms = ms + watch_temp_period * 1000UL;
|
||||
if (!heated) { // If not yet reached target...
|
||||
if (current > next_watch_temp) { // Over the watch temp?
|
||||
next_watch_temp = current + watch_temp_increase; // - set the next temp to watch for
|
||||
temp_change_ms = ms + watch_temp_period * 1000UL; // - move the expiration timer up
|
||||
if (current > watch_temp_target) heated = true; // - Flag if target temperature reached
|
||||
}
|
||||
else if (!heated && ELAPSED(ms, temp_change_ms))
|
||||
else if (ELAPSED(ms, temp_change_ms)) // Watch timer expired
|
||||
_temp_error(hotend, PSTR(MSG_T_HEATING_FAILED), PSTR(MSG_HEATING_FAILED_LCD));
|
||||
else if (heated && input < temp - MAX_OVERSHOOT_PID_AUTOTUNE)
|
||||
}
|
||||
else if (current < target - (MAX_OVERSHOOT_PID_AUTOTUNE)) // Heated, then temperature fell too far?
|
||||
_temp_error(hotend, PSTR(MSG_T_THERMAL_RUNAWAY), PSTR(MSG_THERMAL_RUNAWAY));
|
||||
#endif
|
||||
} // every 2 seconds
|
||||
|
||||
// Timeout after 20 minutes since the last undershoot/overshoot cycle
|
||||
if (((ms - t1) + (ms - t2)) > (20L * 60L * 1000L)) {
|
||||
SERIAL_PROTOCOLLNPGM(MSG_PID_TIMEOUT);
|
||||
break;
|
||||
}
|
||||
|
||||
if (cycles > ncycles) {
|
||||
SERIAL_PROTOCOLLNPGM(MSG_PID_AUTOTUNE_FINISHED);
|
||||
|
||||
|
@ -445,7 +445,7 @@ class Temperature {
|
||||
* Perform auto-tuning for hotend or bed in response to M303
|
||||
*/
|
||||
#if HAS_PID_HEATING
|
||||
static void PID_autotune(const float temp, const int8_t hotend, const int8_t ncycles, const bool set_result=false);
|
||||
static void PID_autotune(const float &target, const int8_t hotend, const int8_t ncycles, const bool set_result=false);
|
||||
|
||||
/**
|
||||
* Update the temp manager when PID values change
|
||||
|
Loading…
Reference in New Issue
Block a user