Shut down heaters during BL-Touch probe event
The electro-magnetic interference from the bed and nozzle are affecting the BL-Touch repeatability for some users. This problem can be helped by shutting down the heaters during the actual probe event and then quickly turning them back on. Because this code is messing with the heaters, it is written in a paranoid manner. It only turns the heaters back on if everything is EXACTLY as it expects things to be. The BL-Touch probe must have been put into a deployed state less than 20 seconds prior, or the stow() function will NOT turn the heaters on. This code has been tested and works for both G28 and probing functions.
This commit is contained in:
parent
3601f08e87
commit
6e8ecb908a
@ -2065,7 +2065,49 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
safe_delay(BLTOUCH_DELAY);
|
||||
}
|
||||
|
||||
//
|
||||
// The BL-Touch probes have a HAL effect sensor. The high currents switching
|
||||
// on and off cause big magnetic fields that can affect the reliability of the
|
||||
// sensor. So, for BL-Touch probes, we turn off the heaters during the actual probe.
|
||||
// And then we quickly turn them back on after we have sampled the point
|
||||
//
|
||||
void turn_heaters_on_or_off_for_bltouch(const bool deploy) {
|
||||
static int8_t bltouch_recursion_cnt=0;
|
||||
static millis_t last_emi_protection=0;
|
||||
static float temps_at_entry[HOTENDS];
|
||||
#if HAS_TEMP_BED
|
||||
static float bed_temp_at_entry;
|
||||
#endif
|
||||
|
||||
if (deploy && bltouch_recursion_cnt>0) // if already in the correct state, we don't need to do anything
|
||||
return; // with the heaters.
|
||||
if (!deploy && bltouch_recursion_cnt<1) // if already in the correct state, we don't need to do anything
|
||||
return; // with the heaters.
|
||||
|
||||
if (deploy) {
|
||||
bltouch_recursion_cnt++;
|
||||
last_emi_protection = millis();
|
||||
HOTEND_LOOP() temps_at_entry[e] = thermalManager.degTargetHotend(e); // save the current target temperatures
|
||||
HOTEND_LOOP() thermalManager.setTargetHotend(0, e); // so we know what to restore them to.
|
||||
|
||||
#if HAS_TEMP_BED
|
||||
bed_temp_at_entry = thermalManager.degTargetBed();
|
||||
thermalManager.setTargetBed(0.0);
|
||||
#endif
|
||||
}
|
||||
else {
|
||||
bltouch_recursion_cnt--; // the heaters are only turned back on
|
||||
if (bltouch_recursion_cnt==0 && ((last_emi_protection+20000L)>millis())) { // if everything is perfect. It is expected
|
||||
HOTEND_LOOP() thermalManager.setTargetHotend(temps_at_entry[e], e); // that the bltouch_recursion_cnt is zero and
|
||||
#if HAS_TEMP_BED // that the heaters were shut off less than
|
||||
thermalManager.setTargetBed(bed_temp_at_entry); // 20 seconds ago
|
||||
#endif
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
void set_bltouch_deployed(const bool deploy) {
|
||||
turn_heaters_on_or_off_for_bltouch(deploy);
|
||||
if (deploy && TEST_BLTOUCH()) { // If BL-Touch says it's triggered
|
||||
bltouch_command(BLTOUCH_RESET); // try to reset it.
|
||||
bltouch_command(BLTOUCH_DEPLOY); // Also needs to deploy and stow to
|
||||
@ -2100,6 +2142,10 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
}
|
||||
#endif
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
turn_heaters_on_or_off_for_bltouch(deploy);
|
||||
#endif
|
||||
|
||||
if (endstops.z_probe_enabled == deploy) return false;
|
||||
|
||||
// Make room for probe
|
||||
|
Loading…
Reference in New Issue
Block a user