Optimize some G76 strings
This commit is contained in:
parent
8690f4862d
commit
7c7d28345e
@ -91,6 +91,12 @@
|
||||
* - `B` - Run bed temperature calibration.
|
||||
* - `P` - Run probe temperature calibration.
|
||||
*/
|
||||
|
||||
static void say_waiting_for() { SERIAL_ECHOPGM("Waiting for "); }
|
||||
static void say_waiting_for_probe_heating() { say_waiting_for(); SERIAL_ECHOLNPGM("probe heating."); }
|
||||
static void say_successfully_calibrated() { SERIAL_ECHOPGM("Successfully calibrated"); }
|
||||
static void say_failed_to_calibrate() { SERIAL_ECHOPGM("!Failed to calibrate"); }
|
||||
|
||||
void GcodeSuite::G76() {
|
||||
// Check if heated bed is available and z-homing is done with probe
|
||||
#if TEMP_SENSOR_BED == 0 || !(HOMING_Z_WITH_PROBE)
|
||||
@ -108,7 +114,7 @@ void GcodeSuite::G76() {
|
||||
};
|
||||
|
||||
auto wait_for_temps = [&](const float tb, const float tp, millis_t &ntr, const millis_t timeout=0) {
|
||||
SERIAL_ECHOLNPGM("Waiting for bed and probe temperature.");
|
||||
say_waiting_for(); SERIAL_ECHOLNPGM("bed and probe temperature.");
|
||||
while (fabs(thermalManager.degBed() - tb) > 0.1f || thermalManager.degProbe() > tp)
|
||||
if (report_temps(ntr, timeout)) return true;
|
||||
return false;
|
||||
@ -184,7 +190,7 @@ void GcodeSuite::G76() {
|
||||
uint16_t target_bed = cali_info_init[TSI_BED].start_temp,
|
||||
target_probe = temp_comp.bed_calib_probe_temp;
|
||||
|
||||
SERIAL_ECHOLNPGM("Waiting for cooling.");
|
||||
say_waiting_for(); SERIAL_ECHOLNPGM(" cooling.");
|
||||
while (thermalManager.degBed() > target_bed || thermalManager.degProbe() > target_probe)
|
||||
report_temps(next_temp_report);
|
||||
|
||||
@ -207,7 +213,8 @@ void GcodeSuite::G76() {
|
||||
|
||||
// Move the nozzle to the probing point and wait for the probe to reach target temp
|
||||
do_blocking_move_to(noz_pos_xyz);
|
||||
SERIAL_ECHOLNPGM("Waiting for probe heating.");
|
||||
say_waiting_for_probe_heating();
|
||||
SERIAL_EOL();
|
||||
while (thermalManager.degProbe() < target_probe)
|
||||
report_temps(next_temp_report);
|
||||
|
||||
@ -216,10 +223,14 @@ void GcodeSuite::G76() {
|
||||
}
|
||||
|
||||
SERIAL_ECHOLNPAIR("Retrieved measurements: ", temp_comp.get_index());
|
||||
if (temp_comp.finish_calibration(TSI_BED))
|
||||
SERIAL_ECHOLNPGM("Successfully calibrated bed.");
|
||||
else
|
||||
SERIAL_ECHOLNPGM("!Failed to calibrate bed. Values reset.");
|
||||
if (temp_comp.finish_calibration(TSI_BED)) {
|
||||
say_successfully_calibrated();
|
||||
SERIAL_ECHOLNPGM(" bed.");
|
||||
}
|
||||
else {
|
||||
say_failed_to_calibrate();
|
||||
SERIAL_ECHOLNPGM(" bed. Values reset.");
|
||||
}
|
||||
|
||||
// Cleanup
|
||||
thermalManager.setTargetBed(0);
|
||||
@ -254,7 +265,8 @@ void GcodeSuite::G76() {
|
||||
// Move probe to probing point and wait for it to reach target temperature
|
||||
do_blocking_move_to(noz_pos_xyz);
|
||||
|
||||
SERIAL_ECHOLNPAIR("Waiting for probe heating. Bed:", target_bed, " Probe:", target_probe);
|
||||
say_waiting_for_probe_heating();
|
||||
SERIAL_ECHOLNPAIR(" Bed:", target_bed, " Probe:", target_probe);
|
||||
const millis_t probe_timeout_ms = millis() + 900UL * 1000UL;
|
||||
while (thermalManager.degProbe() < target_probe) {
|
||||
if (report_temps(next_temp_report, probe_timeout_ms)) {
|
||||
@ -271,9 +283,9 @@ void GcodeSuite::G76() {
|
||||
|
||||
SERIAL_ECHOLNPAIR("Retrieved measurements: ", temp_comp.get_index());
|
||||
if (temp_comp.finish_calibration(TSI_PROBE))
|
||||
SERIAL_ECHOPGM("Successfully calibrated");
|
||||
say_successfully_calibrated();
|
||||
else
|
||||
SERIAL_ECHOPGM("!Failed to calibrate");
|
||||
say_failed_to_calibrate();
|
||||
SERIAL_ECHOLNPGM(" probe.");
|
||||
|
||||
// Cleanup
|
||||
|
Loading…
Reference in New Issue
Block a user