E1+ Autotemp and Planner comments
This commit is contained in:
parent
15bda88d04
commit
9823a37362
@ -587,13 +587,11 @@ namespace ExtUI {
|
||||
|
||||
void setAxisMaxAcceleration_mm_s2(const float &value, const axis_t axis) {
|
||||
planner.set_max_acceleration(axis, value);
|
||||
planner.reset_acceleration_rates();
|
||||
}
|
||||
|
||||
void setAxisMaxAcceleration_mm_s2(const float &value, const extruder_t extruder) {
|
||||
UNUSED_E(extruder);
|
||||
planner.set_max_acceleration(E_AXIS_N(extruder - E0), value);
|
||||
planner.reset_acceleration_rates();
|
||||
}
|
||||
|
||||
#if HAS_FILAMENT_SENSOR
|
||||
|
@ -1248,32 +1248,6 @@ void Planner::recalculate() {
|
||||
recalculate_trapezoids();
|
||||
}
|
||||
|
||||
#if ENABLED(AUTOTEMP)
|
||||
|
||||
void Planner::getHighESpeed() {
|
||||
static float oldt = 0;
|
||||
|
||||
if (!autotemp_enabled) return;
|
||||
if (thermalManager.degTargetHotend(0) + 2 < autotemp_min) return; // probably temperature set to zero.
|
||||
|
||||
float high = 0.0;
|
||||
for (uint8_t b = block_buffer_tail; b != block_buffer_head; b = next_block_index(b)) {
|
||||
block_t* block = &block_buffer[b];
|
||||
if (block->steps.x || block->steps.y || block->steps.z) {
|
||||
const float se = (float)block->steps.e / block->step_event_count * SQRT(block->nominal_speed_sqr); // mm/sec;
|
||||
NOLESS(high, se);
|
||||
}
|
||||
}
|
||||
|
||||
float t = autotemp_min + high * autotemp_factor;
|
||||
LIMIT(t, autotemp_min, autotemp_max);
|
||||
if (t < oldt) t = t * (1 - float(AUTOTEMP_OLDWEIGHT)) + oldt * float(AUTOTEMP_OLDWEIGHT);
|
||||
oldt = t;
|
||||
thermalManager.setTargetHotend(t, 0);
|
||||
}
|
||||
|
||||
#endif // AUTOTEMP
|
||||
|
||||
/**
|
||||
* Maintain fans, paste extruder pressure,
|
||||
*/
|
||||
@ -1398,6 +1372,72 @@ void Planner::check_axes_activity() {
|
||||
#endif
|
||||
}
|
||||
|
||||
#if ENABLED(AUTOTEMP)
|
||||
|
||||
#if ENABLED(AUTOTEMP_PROPORTIONAL)
|
||||
void Planner::_autotemp_update_from_hotend() {
|
||||
const int16_t target = thermalManager.degTargetHotend(active_extruder);
|
||||
autotemp_min = target + AUTOTEMP_MIN_P;
|
||||
autotemp_max = target + AUTOTEMP_MAX_P;
|
||||
}
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Called after changing tools to:
|
||||
* - Reset or re-apply the default proportional autotemp factor.
|
||||
* - Enable autotemp if the factor is non-zero.
|
||||
*/
|
||||
void Planner::autotemp_update() {
|
||||
_autotemp_update_from_hotend();
|
||||
autotemp_factor = TERN(AUTOTEMP_PROPORTIONAL, AUTOTEMP_FACTOR_P, 0);
|
||||
autotemp_enabled = autotemp_factor != 0;
|
||||
}
|
||||
|
||||
/**
|
||||
* Called by the M104/M109 commands after setting Hotend Temperature
|
||||
*
|
||||
*/
|
||||
void Planner::autotemp_M104_M109() {
|
||||
_autotemp_update_from_hotend();
|
||||
|
||||
if (parser.seenval('S')) autotemp_min = parser.value_celsius();
|
||||
if (parser.seenval('B')) autotemp_max = parser.value_celsius();
|
||||
|
||||
// When AUTOTEMP_PROPORTIONAL is enabled, F0 disables autotemp.
|
||||
// Normally, leaving off F also disables autotemp.
|
||||
autotemp_factor = parser.seen('F') ? parser.value_float() : TERN(AUTOTEMP_PROPORTIONAL, AUTOTEMP_FACTOR_P, 0);
|
||||
autotemp_enabled = autotemp_factor != 0;
|
||||
}
|
||||
|
||||
/**
|
||||
* Called every so often to adjust the hotend target temperature
|
||||
* based on the extrusion speed, which is calculated from the blocks
|
||||
* currently in the planner.
|
||||
*/
|
||||
void Planner::getHighESpeed() {
|
||||
static float oldt = 0;
|
||||
|
||||
if (!autotemp_enabled) return;
|
||||
if (thermalManager.degTargetHotend(active_extruder) < autotemp_min - 2) return; // Below the min?
|
||||
|
||||
float high = 0.0;
|
||||
for (uint8_t b = block_buffer_tail; b != block_buffer_head; b = next_block_index(b)) {
|
||||
block_t* block = &block_buffer[b];
|
||||
if (block->steps.x || block->steps.y || block->steps.z) {
|
||||
const float se = (float)block->steps.e / block->step_event_count * SQRT(block->nominal_speed_sqr); // mm/sec;
|
||||
NOLESS(high, se);
|
||||
}
|
||||
}
|
||||
|
||||
float t = autotemp_min + high * autotemp_factor;
|
||||
LIMIT(t, autotemp_min, autotemp_max);
|
||||
if (t < oldt) t *= (1.0f - (AUTOTEMP_OLDWEIGHT)) + oldt * (AUTOTEMP_OLDWEIGHT);
|
||||
oldt = t;
|
||||
thermalManager.setTargetHotend(t, active_extruder);
|
||||
}
|
||||
|
||||
#endif
|
||||
|
||||
#if DISABLED(NO_VOLUMETRICS)
|
||||
|
||||
/**
|
||||
@ -2959,13 +2999,17 @@ void Planner::reset_acceleration_rates() {
|
||||
TERN_(HAS_LINEAR_E_JERK, recalculate_max_e_jerk());
|
||||
}
|
||||
|
||||
// Recalculate position, steps_to_mm if settings.axis_steps_per_mm changes!
|
||||
/**
|
||||
* Recalculate 'position' and 'steps_to_mm'.
|
||||
* Must be called whenever settings.axis_steps_per_mm changes!
|
||||
*/
|
||||
void Planner::refresh_positioning() {
|
||||
LOOP_XYZE_N(i) steps_to_mm[i] = 1.0f / settings.axis_steps_per_mm[i];
|
||||
set_position_mm(current_position);
|
||||
reset_acceleration_rates();
|
||||
}
|
||||
|
||||
// Apply limits to a variable and give a warning if the value was out of range
|
||||
inline void limit_and_warn(float &val, const uint8_t axis, PGM_P const setting_name, const xyze_float_t &max_limit) {
|
||||
const uint8_t lim_axis = axis > E_AXIS ? E_AXIS : axis;
|
||||
const float before = val;
|
||||
@ -2978,7 +3022,14 @@ inline void limit_and_warn(float &val, const uint8_t axis, PGM_P const setting_n
|
||||
}
|
||||
}
|
||||
|
||||
void Planner::set_max_acceleration(const uint8_t axis, float targetValue) {
|
||||
/**
|
||||
* For the specified 'axis' set the Maximum Acceleration to the given value (mm/s^2)
|
||||
* The value may be limited with warning feedback, if configured.
|
||||
* Calls reset_acceleration_rates to precalculate planner terms in steps.
|
||||
*
|
||||
* This hard limit is applied as a block is being added to the planner queue.
|
||||
*/
|
||||
void Planner::set_max_acceleration(const uint8_t axis, const float &inMaxAccelMMS2) {
|
||||
#if ENABLED(LIMITED_MAX_ACCEL_EDITING)
|
||||
#ifdef MAX_ACCEL_EDIT_VALUES
|
||||
constexpr xyze_float_t max_accel_edit = MAX_ACCEL_EDIT_VALUES;
|
||||
@ -2987,15 +3038,21 @@ void Planner::set_max_acceleration(const uint8_t axis, float targetValue) {
|
||||
constexpr xyze_float_t max_accel_edit = DEFAULT_MAX_ACCELERATION;
|
||||
const xyze_float_t max_acc_edit_scaled = max_accel_edit * 2;
|
||||
#endif
|
||||
limit_and_warn(targetValue, axis, PSTR("Acceleration"), max_acc_edit_scaled);
|
||||
limit_and_warn(inMaxAccelMMS2, axis, PSTR("Acceleration"), max_acc_edit_scaled);
|
||||
#endif
|
||||
settings.max_acceleration_mm_per_s2[axis] = targetValue;
|
||||
settings.max_acceleration_mm_per_s2[axis] = inMaxAccelMMS2;
|
||||
|
||||
// Update steps per s2 to agree with the units per s2 (since they are used in the planner)
|
||||
reset_acceleration_rates();
|
||||
}
|
||||
|
||||
void Planner::set_max_feedrate(const uint8_t axis, float targetValue) {
|
||||
/**
|
||||
* For the specified 'axis' set the Maximum Feedrate to the given value (mm/s)
|
||||
* The value may be limited with warning feedback, if configured.
|
||||
*
|
||||
* This hard limit is applied as a block is being added to the planner queue.
|
||||
*/
|
||||
void Planner::set_max_feedrate(const uint8_t axis, const float &inMaxFeedrateMMS) {
|
||||
#if ENABLED(LIMITED_MAX_FR_EDITING)
|
||||
#ifdef MAX_FEEDRATE_EDIT_VALUES
|
||||
constexpr xyze_float_t max_fr_edit = MAX_FEEDRATE_EDIT_VALUES;
|
||||
@ -3004,13 +3061,20 @@ void Planner::set_max_feedrate(const uint8_t axis, float targetValue) {
|
||||
constexpr xyze_float_t max_fr_edit = DEFAULT_MAX_FEEDRATE;
|
||||
const xyze_float_t max_fr_edit_scaled = max_fr_edit * 2;
|
||||
#endif
|
||||
limit_and_warn(targetValue, axis, PSTR("Feedrate"), max_fr_edit_scaled);
|
||||
limit_and_warn(inMaxFeedrateMMS, axis, PSTR("Feedrate"), max_fr_edit_scaled);
|
||||
#endif
|
||||
settings.max_feedrate_mm_s[axis] = targetValue;
|
||||
settings.max_feedrate_mm_s[axis] = inMaxFeedrateMMS;
|
||||
}
|
||||
|
||||
void Planner::set_max_jerk(const AxisEnum axis, float targetValue) {
|
||||
#if HAS_CLASSIC_JERK
|
||||
|
||||
/**
|
||||
* For the specified 'axis' set the Maximum Jerk (instant change) to the given value (mm/s)
|
||||
* The value may be limited with warning feedback, if configured.
|
||||
*
|
||||
* This hard limit is applied (to the block start speed) as the block is being added to the planner queue.
|
||||
*/
|
||||
void Planner::set_max_jerk(const AxisEnum axis, const float &targetValue) {
|
||||
#if ENABLED(LIMITED_JERK_EDITING)
|
||||
constexpr xyze_float_t max_jerk_edit =
|
||||
#ifdef MAX_JERK_EDIT_VALUES
|
||||
@ -3023,11 +3087,10 @@ void Planner::set_max_jerk(const AxisEnum axis, float targetValue) {
|
||||
limit_and_warn(targetValue, axis, PSTR("Jerk"), max_jerk_edit);
|
||||
#endif
|
||||
max_jerk[axis] = targetValue;
|
||||
#else
|
||||
UNUSED(axis); UNUSED(targetValue);
|
||||
#endif
|
||||
}
|
||||
|
||||
#endif
|
||||
|
||||
#if HAS_WIRED_LCD
|
||||
|
||||
uint16_t Planner::block_buffer_runtime() {
|
||||
@ -3069,33 +3132,3 @@ void Planner::set_max_jerk(const AxisEnum axis, float targetValue) {
|
||||
}
|
||||
|
||||
#endif
|
||||
|
||||
#if ENABLED(AUTOTEMP)
|
||||
|
||||
void Planner::autotemp_update() {
|
||||
#if ENABLED(AUTOTEMP_PROPORTIONAL)
|
||||
const int16_t target = thermalManager.degTargetHotend(active_extruder);
|
||||
autotemp_min = target + AUTOTEMP_MIN_P;
|
||||
autotemp_max = target + AUTOTEMP_MAX_P;
|
||||
#endif
|
||||
autotemp_factor = TERN(AUTOTEMP_PROPORTIONAL, AUTOTEMP_FACTOR_P, 0);
|
||||
autotemp_enabled = autotemp_factor != 0;
|
||||
}
|
||||
|
||||
void Planner::autotemp_M104_M109() {
|
||||
|
||||
#if ENABLED(AUTOTEMP_PROPORTIONAL)
|
||||
const int16_t target = thermalManager.degTargetHotend(active_extruder);
|
||||
autotemp_min = target + AUTOTEMP_MIN_P;
|
||||
autotemp_max = target + AUTOTEMP_MAX_P;
|
||||
#endif
|
||||
|
||||
if (parser.seenval('S')) autotemp_min = parser.value_celsius();
|
||||
if (parser.seenval('B')) autotemp_max = parser.value_celsius();
|
||||
|
||||
// When AUTOTEMP_PROPORTIONAL is enabled, F0 disables autotemp.
|
||||
// Normally, leaving off F also disables autotemp.
|
||||
autotemp_factor = parser.seen('F') ? parser.value_float() : TERN(AUTOTEMP_PROPORTIONAL, AUTOTEMP_FACTOR_P, 0);
|
||||
autotemp_enabled = autotemp_factor != 0;
|
||||
}
|
||||
#endif
|
||||
|
@ -460,12 +460,27 @@ class Planner {
|
||||
* Static (class) Methods
|
||||
*/
|
||||
|
||||
// Recalculate steps/s^2 accelerations based on mm/s^2 settings
|
||||
static void reset_acceleration_rates();
|
||||
static void refresh_positioning();
|
||||
static void set_max_acceleration(const uint8_t axis, float targetValue);
|
||||
static void set_max_feedrate(const uint8_t axis, float targetValue);
|
||||
static void set_max_jerk(const AxisEnum axis, float targetValue);
|
||||
|
||||
/**
|
||||
* Recalculate 'position' and 'steps_to_mm'.
|
||||
* Must be called whenever settings.axis_steps_per_mm changes!
|
||||
*/
|
||||
static void refresh_positioning();
|
||||
|
||||
// For an axis set the Maximum Acceleration in mm/s^2
|
||||
static void set_max_acceleration(const uint8_t axis, const float &inMaxAccelMMS2);
|
||||
|
||||
// For an axis set the Maximum Feedrate in mm/s
|
||||
static void set_max_feedrate(const uint8_t axis, const float &inMaxFeedrateMMS);
|
||||
|
||||
// For an axis set the Maximum Jerk (instant change) in mm/s
|
||||
#if HAS_CLASSIC_JERK
|
||||
static void set_max_jerk(const AxisEnum axis, const float &inMaxJerkMMS);
|
||||
#else
|
||||
static inline void set_max_jerk(const AxisEnum, const float&) {}
|
||||
#endif
|
||||
|
||||
#if EXTRUDERS
|
||||
FORCE_INLINE static void refresh_e_factor(const uint8_t e) {
|
||||
@ -883,9 +898,9 @@ class Planner {
|
||||
#if ENABLED(AUTOTEMP)
|
||||
static float autotemp_min, autotemp_max, autotemp_factor;
|
||||
static bool autotemp_enabled;
|
||||
static void getHighESpeed();
|
||||
static void autotemp_M104_M109();
|
||||
static void autotemp_update();
|
||||
static void autotemp_M104_M109();
|
||||
static void getHighESpeed();
|
||||
#endif
|
||||
|
||||
#if HAS_LINEAR_E_JERK
|
||||
@ -898,6 +913,14 @@ class Planner {
|
||||
|
||||
private:
|
||||
|
||||
#if ENABLED(AUTOTEMP)
|
||||
#if ENABLED(AUTOTEMP_PROPORTIONAL)
|
||||
static void _autotemp_update_from_hotend();
|
||||
#else
|
||||
static inline void _autotemp_update_from_hotend() {}
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Get the index of the next / previous block in the ring buffer
|
||||
*/
|
||||
|
Loading…
Reference in New Issue
Block a user