diff --git a/Marlin/Conditionals_LCD.h b/Marlin/Conditionals_LCD.h index 9f27bd29ca..862e4827b8 100644 --- a/Marlin/Conditionals_LCD.h +++ b/Marlin/Conditionals_LCD.h @@ -371,12 +371,12 @@ /** * Set a flag for any enabled probe */ - #define PROBE_SELECTED (ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED)) + #define PROBE_SELECTED (ENABLED(PROBE_MANUALLY) || ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED)) /** * Clear probe pin settings when no probe is selected */ - #if !PROBE_SELECTED + #if !PROBE_SELECTED || ENABLED(PROBE_MANUALLY) #undef Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN #undef Z_MIN_PROBE_ENDSTOP #endif diff --git a/Marlin/Conditionals_post.h b/Marlin/Conditionals_post.h index 6594840808..b189af507c 100644 --- a/Marlin/Conditionals_post.h +++ b/Marlin/Conditionals_post.h @@ -589,7 +589,7 @@ #define PROBE_PIN_CONFIGURED (HAS_Z_MIN_PROBE_PIN || (HAS_Z_MIN && ENABLED(Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN))) - #define HAS_BED_PROBE (PROBE_SELECTED && PROBE_PIN_CONFIGURED) + #define HAS_BED_PROBE (PROBE_SELECTED && PROBE_PIN_CONFIGURED && DISABLED(PROBE_MANUALLY)) #if ENABLED(Z_PROBE_ALLEN_KEY) #define PROBE_IS_TRIGGERED_WHEN_STOWED_TEST diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index d72e77d0e1..bb554fa86a 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -876,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1432,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/SanityCheck.h b/Marlin/SanityCheck.h index 3941e6fb27..5ab7181c68 100644 --- a/Marlin/SanityCheck.h +++ b/Marlin/SanityCheck.h @@ -130,8 +130,12 @@ #error "Z_RAISE_PROBE_DEPLOY_STOW and Z_RAISE_BETWEEN_PROBINGS are now Z_CLEARANCE_DEPLOY_PROBE and Z_CLEARANCE_BETWEEN_PROBES. Please update your configuration." #elif defined(Z_PROBE_DEPLOY_HEIGHT) || defined(Z_PROBE_TRAVEL_HEIGHT) #error "Z_PROBE_DEPLOY_HEIGHT and Z_PROBE_TRAVEL_HEIGHT are now Z_CLEARANCE_DEPLOY_PROBE and Z_CLEARANCE_BETWEEN_PROBES. Please update your configuration." +#elif defined(MANUAL_BED_LEVELING) + #error "MANUAL_BED_LEVELING is now LCD_BED_LEVELING. Please update your configuration." #elif defined(MESH_HOME_SEARCH_Z) - #error "MESH_HOME_SEARCH_Z is now MANUAL_PROBE_Z_RANGE. Please update your configuration." + #error "MESH_HOME_SEARCH_Z is now LCD_PROBE_Z_RANGE. Please update your configuration." +#elif defined(MANUAL_PROBE_Z_RANGE) + #error "MANUAL_PROBE_Z_RANGE is now LCD_PROBE_Z_RANGE. Please update your configuration." #elif !defined(MIN_STEPS_PER_SEGMENT) #error Please replace "const int dropsegments" with "#define MIN_STEPS_PER_SEGMENT" (and increase by 1) in Configuration_adv.h. #elif defined(PREVENT_DANGEROUS_EXTRUDE) @@ -408,8 +412,6 @@ static_assert(1 >= 0 #elif MESH_NUM_X_POINTS > 9 || MESH_NUM_Y_POINTS > 9 #error "MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS must be less than 10." #endif -#elif ENABLED(MANUAL_BED_LEVELING) - #error "MANUAL_BED_LEVELING only applies to MESH_BED_LEVELING." #endif /** @@ -492,7 +494,7 @@ static_assert(1 >= 0 #if !HAS_Z_MIN_PROBE_PIN #error "Z_MIN_PROBE_ENDSTOP requires the Z_MIN_PROBE_PIN to be defined." #endif - #else + #elif DISABLED(PROBE_MANUALLY) #error "You must enable either Z_MIN_PROBE_ENDSTOP or Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use a probe." #endif @@ -523,10 +525,10 @@ static_assert(1 >= 0 #endif /** - * MANUAL_BED_LEVELING requirements + * LCD_BED_LEVELING requirements */ -#if ENABLED(MANUAL_BED_LEVELING) && DISABLED(MESH_BED_LEVELING) - #error "MANUAL_BED_LEVELING requires MESH_BED_LEVELING." +#if ENABLED(LCD_BED_LEVELING) && DISABLED(MESH_BED_LEVELING) && !(HAS_ABL && ENABLED(PROBE_MANUALLY)) + #error "LCD_BED_LEVELING requires MESH_BED_LEVELING or PROBE_MANUALLY." #endif /** diff --git a/Marlin/example_configurations/Cartesio/Configuration.h b/Marlin/example_configurations/Cartesio/Configuration.h index 22cf260ffe..3fd0a7b4a0 100644 --- a/Marlin/example_configurations/Cartesio/Configuration.h +++ b/Marlin/example_configurations/Cartesio/Configuration.h @@ -232,7 +232,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -741,7 +746,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -877,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1433,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) #define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/Felix/Configuration.h b/Marlin/example_configurations/Felix/Configuration.h index b7cea166ec..0c7d070f77 100644 --- a/Marlin/example_configurations/Felix/Configuration.h +++ b/Marlin/example_configurations/Felix/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -528,6 +528,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -724,7 +729,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -860,15 +864,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1416,13 +1424,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/Felix/DUAL/Configuration.h b/Marlin/example_configurations/Felix/DUAL/Configuration.h index fe23cecac7..1b73fd4087 100644 --- a/Marlin/example_configurations/Felix/DUAL/Configuration.h +++ b/Marlin/example_configurations/Felix/DUAL/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -528,6 +528,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -724,7 +729,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -860,15 +864,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1416,13 +1424,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/Hephestos/Configuration.h b/Marlin/example_configurations/Hephestos/Configuration.h index 7427ddd02f..9ea0b4b234 100644 --- a/Marlin/example_configurations/Hephestos/Configuration.h +++ b/Marlin/example_configurations/Hephestos/Configuration.h @@ -234,7 +234,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -537,6 +537,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -733,7 +738,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -869,15 +873,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1425,13 +1433,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/Hephestos_2/Configuration.h b/Marlin/example_configurations/Hephestos_2/Configuration.h index 920c160b4e..8001b300d9 100644 --- a/Marlin/example_configurations/Hephestos_2/Configuration.h +++ b/Marlin/example_configurations/Hephestos_2/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -539,6 +539,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -735,7 +740,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -871,15 +875,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1427,13 +1435,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/K8200/Configuration.h b/Marlin/example_configurations/K8200/Configuration.h index 240514fa66..d490c9bbf5 100644 --- a/Marlin/example_configurations/K8200/Configuration.h +++ b/Marlin/example_configurations/K8200/Configuration.h @@ -251,7 +251,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -574,6 +574,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -770,7 +775,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -906,15 +910,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1467,13 +1475,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/K8400/Configuration.h b/Marlin/example_configurations/K8400/Configuration.h index 55bbf2b0b1..a76a149ba8 100644 --- a/Marlin/example_configurations/K8400/Configuration.h +++ b/Marlin/example_configurations/K8400/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -741,7 +746,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -877,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1433,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/K8400/Dual-head/Configuration.h b/Marlin/example_configurations/K8400/Dual-head/Configuration.h index 53515a7ab3..784af8ef6a 100644 --- a/Marlin/example_configurations/K8400/Dual-head/Configuration.h +++ b/Marlin/example_configurations/K8400/Dual-head/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -741,7 +746,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -877,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1433,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h index 787adad89a..53634f5f5e 100644 --- a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h +++ b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -741,7 +746,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -877,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1433,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/RigidBot/Configuration.h b/Marlin/example_configurations/RigidBot/Configuration.h index 554b9940df..77a19b7e01 100644 --- a/Marlin/example_configurations/RigidBot/Configuration.h +++ b/Marlin/example_configurations/RigidBot/Configuration.h @@ -234,7 +234,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -544,6 +544,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -740,7 +745,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -876,15 +880,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1434,13 +1442,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/SCARA/Configuration.h b/Marlin/example_configurations/SCARA/Configuration.h index 2b88b983e6..9ae75f3914 100644 --- a/Marlin/example_configurations/SCARA/Configuration.h +++ b/Marlin/example_configurations/SCARA/Configuration.h @@ -263,7 +263,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -560,6 +560,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -756,7 +761,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -892,15 +896,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1448,13 +1456,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/TAZ4/Configuration.h b/Marlin/example_configurations/TAZ4/Configuration.h index b484352edc..9e1466db8a 100644 --- a/Marlin/example_configurations/TAZ4/Configuration.h +++ b/Marlin/example_configurations/TAZ4/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -566,6 +566,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -762,7 +767,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -898,15 +902,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1454,13 +1462,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/WITBOX/Configuration.h b/Marlin/example_configurations/WITBOX/Configuration.h index b7e5f255ab..2375986b75 100644 --- a/Marlin/example_configurations/WITBOX/Configuration.h +++ b/Marlin/example_configurations/WITBOX/Configuration.h @@ -234,7 +234,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -537,6 +537,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -733,7 +738,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -869,15 +873,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1425,13 +1433,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/adafruit/ST7565/Configuration.h b/Marlin/example_configurations/adafruit/ST7565/Configuration.h index b392667a0a..57e23c03ec 100644 --- a/Marlin/example_configurations/adafruit/ST7565/Configuration.h +++ b/Marlin/example_configurations/adafruit/ST7565/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -545,6 +545,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -741,7 +746,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -877,15 +881,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1433,13 +1441,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/delta/flsun_kossel_mini/Configuration.h b/Marlin/example_configurations/delta/flsun_kossel_mini/Configuration.h index 5097bd3e4c..e3851c9291 100644 --- a/Marlin/example_configurations/delta/flsun_kossel_mini/Configuration.h +++ b/Marlin/example_configurations/delta/flsun_kossel_mini/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -603,6 +603,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -982,15 +987,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1538,13 +1547,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/delta/generic/Configuration.h b/Marlin/example_configurations/delta/generic/Configuration.h index 893b002fbb..4682962f40 100644 --- a/Marlin/example_configurations/delta/generic/Configuration.h +++ b/Marlin/example_configurations/delta/generic/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -590,6 +590,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -831,7 +836,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -968,15 +972,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1523,13 +1531,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/delta/kossel_mini/Configuration.h b/Marlin/example_configurations/delta/kossel_mini/Configuration.h index 40181a3c28..fbb17466ba 100644 --- a/Marlin/example_configurations/delta/kossel_mini/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_mini/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -590,6 +590,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -834,7 +839,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -972,15 +976,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1527,13 +1535,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/delta/kossel_pro/Configuration.h b/Marlin/example_configurations/delta/kossel_pro/Configuration.h index e6b76b50bc..81d935c9cb 100644 --- a/Marlin/example_configurations/delta/kossel_pro/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_pro/Configuration.h @@ -235,7 +235,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -584,6 +584,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -833,7 +838,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -971,15 +975,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1526,13 +1534,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/delta/kossel_xl/Configuration.h b/Marlin/example_configurations/delta/kossel_xl/Configuration.h index 88a613b92f..9403f44310 100644 --- a/Marlin/example_configurations/delta/kossel_xl/Configuration.h +++ b/Marlin/example_configurations/delta/kossel_xl/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -603,6 +603,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -844,7 +849,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -981,15 +985,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1536,13 +1544,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/makibox/Configuration.h b/Marlin/example_configurations/makibox/Configuration.h index 3023e20597..3f4a978daa 100644 --- a/Marlin/example_configurations/makibox/Configuration.h +++ b/Marlin/example_configurations/makibox/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -548,6 +548,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -744,7 +749,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -880,15 +884,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1436,13 +1444,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote diff --git a/Marlin/example_configurations/tvrrug/Round2/Configuration.h b/Marlin/example_configurations/tvrrug/Round2/Configuration.h index 0c7331fc98..da09617910 100644 --- a/Marlin/example_configurations/tvrrug/Round2/Configuration.h +++ b/Marlin/example_configurations/tvrrug/Round2/Configuration.h @@ -231,7 +231,7 @@ * 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950 * 66 : 4.7M High Temperature thermistor from Dyze Design * 70 : the 100K thermistor found in the bq Hephestos 2 - * 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor + * 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor * * 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k. * (but gives greater accuracy and more stable PID) @@ -541,6 +541,11 @@ // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500. // +// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe. +// Use G29 repeatedly, adjusting the Z height at each point with movement commands +// or (with LCD_BED_LEVELING) the LCD controller. +//#define PROBE_MANUALLY + // A Fix-Mounted Probe either doesn't deploy or needs manual deployment. // For example an inductive probe, or a setup that uses the nozzle to probe. // An inductive probe must be deactivated to go below @@ -737,7 +742,6 @@ #define FILAMENT_RUNOUT_SCRIPT "M600" #endif - //=========================================================================== //=============================== Bed Leveling ============================== //=========================================================================== @@ -873,15 +877,19 @@ //#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS - //#define MANUAL_BED_LEVELING // Add display menu option for bed leveling. - #define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment - - #if ENABLED(MANUAL_BED_LEVELING) - #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. - #endif - #endif // BED_LEVELING +/** + * Use the LCD controller for bed leveling + * Requires MESH_BED_LEVELING or PROBE_MANUALLY + */ +//#define LCD_BED_LEVELING + +#if ENABLED(LCD_BED_LEVELING) + #define MBL_Z_STEP 0.025 // Step size while manually probing Z axis. + #define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment +#endif + /** * Commands to execute at the end of G29 probing. * Useful to retract or move the Z probe out of the way. @@ -1429,13 +1437,13 @@ // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can // be used to mitigate the associated resolution loss. If enabled, -// some of the PWM cycles are stretched so on average the wanted +// some of the PWM cycles are stretched so on average the desired // duty cycle is attained. //#define SOFT_PWM_DITHER // Temperature status LEDs that display the hotend and bed temperature. -// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on. -// Otherwise the RED led is on. There is 1C hysteresis. +// If all hotends, bed temperature, and target temperature are under 54C +// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis) //#define TEMP_STAT_LEDS // M240 Triggers a camera by emulating a Canon RC-1 Remote