Add UUID support to M115 responses.
This commit is contained in:
parent
c184f808f7
commit
a5e8575829
@ -70,6 +70,10 @@
|
|||||||
// Define this to set a custom name for your generic Mendel,
|
// Define this to set a custom name for your generic Mendel,
|
||||||
// #define CUSTOM_MENDEL_NAME "This Mendel"
|
// #define CUSTOM_MENDEL_NAME "This Mendel"
|
||||||
|
|
||||||
|
// Define this to set a unique identifier for this printer, (Used by some programs to differentiate between machines)
|
||||||
|
// You can use an online service to generate a random UUID. (eg http://www.uuidgenerator.net/version4)
|
||||||
|
// #define MACHINE_UUID "00000000-0000-0000-0000-000000000000"
|
||||||
|
|
||||||
// This defines the number of extruders
|
// This defines the number of extruders
|
||||||
#define EXTRUDERS 1
|
#define EXTRUDERS 1
|
||||||
|
|
||||||
@ -96,7 +100,7 @@
|
|||||||
// 2 is 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup)
|
// 2 is 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup)
|
||||||
// 3 is mendel-parts thermistor (4.7k pullup)
|
// 3 is mendel-parts thermistor (4.7k pullup)
|
||||||
// 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
|
// 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
|
||||||
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup)
|
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup)
|
||||||
// 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
|
// 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
|
||||||
// 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
|
// 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
|
||||||
// 71 is 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup)
|
// 71 is 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup)
|
||||||
@ -109,7 +113,7 @@
|
|||||||
// (but gives greater accuracy and more stable PID)
|
// (but gives greater accuracy and more stable PID)
|
||||||
// 51 is 100k thermistor - EPCOS (1k pullup)
|
// 51 is 100k thermistor - EPCOS (1k pullup)
|
||||||
// 52 is 200k thermistor - ATC Semitec 204GT-2 (1k pullup)
|
// 52 is 200k thermistor - ATC Semitec 204GT-2 (1k pullup)
|
||||||
// 55 is 100k thermistor - ATC Semitec 104GT-2 (Used in ParCan) (1k pullup)
|
// 55 is 100k thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (1k pullup)
|
||||||
|
|
||||||
#define TEMP_SENSOR_0 -1
|
#define TEMP_SENSOR_0 -1
|
||||||
#define TEMP_SENSOR_1 -1
|
#define TEMP_SENSOR_1 -1
|
||||||
|
@ -38,6 +38,9 @@
|
|||||||
#else
|
#else
|
||||||
#define MACHINE_NAME "Mendel"
|
#define MACHINE_NAME "Mendel"
|
||||||
#endif
|
#endif
|
||||||
|
#ifndef MACHINE_UUID
|
||||||
|
#define MACHINE_UUID "00000000-0000-0000-0000-000000000000"
|
||||||
|
#endif
|
||||||
#define FIRMWARE_URL "http://www.mendel-parts.com"
|
#define FIRMWARE_URL "http://www.mendel-parts.com"
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
@ -163,7 +166,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Heating done."
|
#define MSG_HEATING_COMPLETE "Heating done."
|
||||||
#define MSG_BED_HEATING "Bed Heating."
|
#define MSG_BED_HEATING "Bed Heating."
|
||||||
#define MSG_BED_DONE "Bed done."
|
#define MSG_BED_DONE "Bed done."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Count X: "
|
#define MSG_COUNT_X " Count X: "
|
||||||
#define MSG_ERR_KILLED "Printer halted. kill() called!"
|
#define MSG_ERR_KILLED "Printer halted. kill() called!"
|
||||||
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
|
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
|
||||||
@ -328,7 +331,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Nagrzewanie ekstrudera zakonczone."
|
#define MSG_HEATING_COMPLETE "Nagrzewanie ekstrudera zakonczone."
|
||||||
#define MSG_BED_HEATING "Nagrzewanie loza..."
|
#define MSG_BED_HEATING "Nagrzewanie loza..."
|
||||||
#define MSG_BED_DONE "Nagrzewanie loza zakonczone."
|
#define MSG_BED_DONE "Nagrzewanie loza zakonczone."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Liczenie X: "
|
#define MSG_COUNT_X " Liczenie X: "
|
||||||
#define MSG_ERR_KILLED "Drukarka zatrzymana. Wywolano kill()"
|
#define MSG_ERR_KILLED "Drukarka zatrzymana. Wywolano kill()"
|
||||||
#define MSG_ERR_STOPPED "Drukarka zatrzymana z powodu bledu. Usun problem i zrestartuj drukartke komenda M999. (temperatura zostala zresetowana; ustaw temperature po restarcie)"
|
#define MSG_ERR_STOPPED "Drukarka zatrzymana z powodu bledu. Usun problem i zrestartuj drukartke komenda M999. (temperatura zostala zresetowana; ustaw temperature po restarcie)"
|
||||||
@ -492,7 +495,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Chauffe terminee."
|
#define MSG_HEATING_COMPLETE "Chauffe terminee."
|
||||||
#define MSG_BED_HEATING "Chauffe du lit."
|
#define MSG_BED_HEATING "Chauffe du lit."
|
||||||
#define MSG_BED_DONE "Chauffe du lit terminee."
|
#define MSG_BED_DONE "Chauffe du lit terminee."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Compteur X: "
|
#define MSG_COUNT_X " Compteur X: "
|
||||||
#define MSG_ERR_KILLED "Impression arretee. kill() appelee!"
|
#define MSG_ERR_KILLED "Impression arretee. kill() appelee!"
|
||||||
#define MSG_ERR_STOPPED "Impression arretee a cause d'erreurs. Corriger les erreurs et utiliser M999 pour la reprendre. (Temperature remise a zero. Reactivez la apres redemarrage)"
|
#define MSG_ERR_STOPPED "Impression arretee a cause d'erreurs. Corriger les erreurs et utiliser M999 pour la reprendre. (Temperature remise a zero. Reactivez la apres redemarrage)"
|
||||||
@ -659,7 +662,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Heating done."
|
#define MSG_HEATING_COMPLETE "Heating done."
|
||||||
#define MSG_BED_HEATING "Bed Heating."
|
#define MSG_BED_HEATING "Bed Heating."
|
||||||
#define MSG_BED_DONE "Bed done."
|
#define MSG_BED_DONE "Bed done."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Count X:"
|
#define MSG_COUNT_X " Count X:"
|
||||||
#define MSG_ERR_KILLED "Printer halted. kill() called !!"
|
#define MSG_ERR_KILLED "Printer halted. kill() called !!"
|
||||||
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart!"
|
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart!"
|
||||||
@ -830,7 +833,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Calentamiento Hecho."
|
#define MSG_HEATING_COMPLETE "Calentamiento Hecho."
|
||||||
#define MSG_BED_HEATING "Calentando la base."
|
#define MSG_BED_HEATING "Calentando la base."
|
||||||
#define MSG_BED_DONE "Base Caliente."
|
#define MSG_BED_DONE "Base Caliente."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Cuenta X:"
|
#define MSG_COUNT_X " Cuenta X:"
|
||||||
#define MSG_ERR_KILLED "¡¡Impresora Parada con kill()!!"
|
#define MSG_ERR_KILLED "¡¡Impresora Parada con kill()!!"
|
||||||
#define MSG_ERR_STOPPED "¡Impresora parada por errores. Arregle el error y use M999 Para reiniciar!. (La temperatura se reestablece. Ajustela antes de continuar)"
|
#define MSG_ERR_STOPPED "¡Impresora parada por errores. Arregle el error y use M999 Para reiniciar!. (La temperatura se reestablece. Ajustela antes de continuar)"
|
||||||
@ -991,7 +994,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Наргето. "
|
#define MSG_HEATING_COMPLETE "Наргето. "
|
||||||
#define MSG_BED_HEATING "Нагрев стола... "
|
#define MSG_BED_HEATING "Нагрев стола... "
|
||||||
#define MSG_BED_DONE "Стол нагрет. "
|
#define MSG_BED_DONE "Стол нагрет. "
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Count X:"
|
#define MSG_COUNT_X " Count X:"
|
||||||
#define MSG_ERR_KILLED "Принтер остановлен. вызов kill() !!"
|
#define MSG_ERR_KILLED "Принтер остановлен. вызов kill() !!"
|
||||||
#define MSG_ERR_STOPPED "Ошибка принтера, останов. Устраните неисправность и используйте M999 для перезагрузки!. (Температура недоступна. Проверьте датчики)"
|
#define MSG_ERR_STOPPED "Ошибка принтера, останов. Устраните неисправность и используйте M999 для перезагрузки!. (Температура недоступна. Проверьте датчики)"
|
||||||
@ -1152,7 +1155,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Stampante Calda."
|
#define MSG_HEATING_COMPLETE "Stampante Calda."
|
||||||
#define MSG_BED_HEATING "Riscaldamento Piatto."
|
#define MSG_BED_HEATING "Riscaldamento Piatto."
|
||||||
#define MSG_BED_DONE "Piatto Pronto."
|
#define MSG_BED_DONE "Piatto Pronto."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Calcola X: "
|
#define MSG_COUNT_X " Calcola X: "
|
||||||
#define MSG_ERR_KILLED "Stampante Calda. kill() chiamata !!"
|
#define MSG_ERR_KILLED "Stampante Calda. kill() chiamata !!"
|
||||||
#define MSG_ERR_STOPPED "Stampante fermata a causa di errori. Risolvi l'errore e usa M999 per ripartire!. (Reset temperatura. Impostala prima di ripartire)"
|
#define MSG_ERR_STOPPED "Stampante fermata a causa di errori. Risolvi l'errore e usa M999 per ripartire!. (Reset temperatura. Impostala prima di ripartire)"
|
||||||
@ -1322,7 +1325,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Aquecido."
|
#define MSG_HEATING_COMPLETE "Aquecido."
|
||||||
#define MSG_BED_HEATING "Aquecendo a Base."
|
#define MSG_BED_HEATING "Aquecendo a Base."
|
||||||
#define MSG_BED_DONE "Base quente."
|
#define MSG_BED_DONE "Base quente."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Conta X:"
|
#define MSG_COUNT_X " Conta X:"
|
||||||
#define MSG_ERR_KILLED "Impressora parada com kill() !!"
|
#define MSG_ERR_KILLED "Impressora parada com kill() !!"
|
||||||
#define MSG_ERR_STOPPED "Impressora parada por erros. Coserte o erro e use M999 para recomeçar!. (Temperatura reiniciada. Ajuste antes de recomeçar)"
|
#define MSG_ERR_STOPPED "Impressora parada por erros. Coserte o erro e use M999 para recomeçar!. (Temperatura reiniciada. Ajuste antes de recomeçar)"
|
||||||
@ -1488,7 +1491,7 @@
|
|||||||
#define MSG_HEATING_COMPLETE "Lammitys valmis."
|
#define MSG_HEATING_COMPLETE "Lammitys valmis."
|
||||||
#define MSG_BED_HEATING "Alusta lampiaa."
|
#define MSG_BED_HEATING "Alusta lampiaa."
|
||||||
#define MSG_BED_DONE "Alusta valmis."
|
#define MSG_BED_DONE "Alusta valmis."
|
||||||
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
|
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
|
||||||
#define MSG_COUNT_X " Laskuri X: "
|
#define MSG_COUNT_X " Laskuri X: "
|
||||||
#define MSG_ERR_KILLED "Tulostin pysaytetty. kill():ia kutsuttu!"
|
#define MSG_ERR_KILLED "Tulostin pysaytetty. kill():ia kutsuttu!"
|
||||||
#define MSG_ERR_STOPPED "Tulostin pysaytetty virheiden vuoksi. Korjaa virheet ja kayta M999 kaynnistaaksesi uudelleen. (Lampotila nollattiin. Aseta lampotila sen jalkeen kun jatkat.)"
|
#define MSG_ERR_STOPPED "Tulostin pysaytetty virheiden vuoksi. Korjaa virheet ja kayta M999 kaynnistaaksesi uudelleen. (Lampotila nollattiin. Aseta lampotila sen jalkeen kun jatkat.)"
|
||||||
|
Loading…
Reference in New Issue
Block a user