From badbb4a500f1a583e059b1085f533f6454ead023 Mon Sep 17 00:00:00 2001 From: Ste Date: Tue, 30 Mar 2021 04:07:21 +0200 Subject: [PATCH] Align temp settings (#21329) --- Marlin/Configuration.h | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index c9c83f9bb6..f333c3369b 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -437,17 +437,17 @@ //#define TEMP_SENSOR_1_AS_REDUNDANT #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10 -#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 -#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer -#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target +#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109 +#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target -#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 -#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer -#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target +#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190 +#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target #define TEMP_CHAMBER_RESIDENCY_TIME 10 // (seconds) Time to wait for chamber to "settle" in M191 -#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer -#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target +#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer +#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target // Below this temperature the heater will be switched off // because it probably indicates a broken thermistor wire.