🐛 Fix HAS_KILL && SOFT_RESET_ON_KILL soft reset button logic (#22269)

This commit is contained in:
Skruppy 2021-07-10 01:25:47 +02:00 committed by Scott Lahteine
parent 69b44c2309
commit eafb94e72d

View File

@ -890,11 +890,11 @@ void minkill(const bool steppers_off/*=false*/) {
#if EITHER(HAS_KILL, SOFT_RESET_ON_KILL)
// Wait for both KILL and ENC to be released
while (TERN0(HAS_KILL, !kill_state()) || TERN0(SOFT_RESET_ON_KILL, !ui.button_pressed()))
while (TERN0(HAS_KILL, kill_state()) || TERN0(SOFT_RESET_ON_KILL, ui.button_pressed()))
watchdog_refresh();
// Wait for either KILL or ENC press
while (TERN1(HAS_KILL, kill_state()) && TERN1(SOFT_RESET_ON_KILL, ui.button_pressed()))
// Wait for either KILL or ENC to be pressed again
while (TERN1(HAS_KILL, !kill_state()) && TERN1(SOFT_RESET_ON_KILL, !ui.button_pressed()))
watchdog_refresh();
// Reboot the board