* Marlin 3D Printer Firmware
|
|
* Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
|
|
*
|
|
* Based on Sprinter and grbl.
|
|
* Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
|
|
*
|
|
* This program is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program. If not, see <https://www.gnu.org/licenses/>.
|
|
*
|
|
*/
|
|
#pragma once
|
|
|
|
#include "../inc/MarlinConfig.h"
|
|
#include "../module/planner.h"
|
|
#include "../module/thermistor/thermistors.h"
|
|
|
|
class FilamentWidthSensor {
|
|
public:
|
|
static constexpr int MMD_CM = MAX_MEASUREMENT_DELAY + 1, MMD_MM = MMD_CM * 10;
|
|
static bool enabled; // (M405-M406) Filament Width Sensor ON/OFF.
|
|
static uint32_t accum; // ADC accumulator
|
|
static uint16_t raw; // Measured filament diameter - one extruder only
|
|
static float nominal_mm, // (M104) Nominal filament width
|
|
measured_mm, // Measured filament diameter
|
|
e_count, delay_dist;
|
|
static uint8_t meas_delay_cm; // Distance delay setting
|
|
static int8_t ratios[MMD_CM], // Ring buffer to delay measurement. (Extruder factor minus 100)
|
|
index_r, index_w; // Indexes into ring buffer
|
|
|
|
FilamentWidthSensor() { init(); }
|
|
static void init();
|
|
|
|
static inline void enable(const bool ena) { enabled = ena; }
|
|
|
|
static inline void set_delay_cm(const uint8_t cm) {
|
|
meas_delay_cm = _MIN(cm, MAX_MEASUREMENT_DELAY);
|
|
}
|
|
|
|
/**
|
|
* Convert Filament Width (mm) to an extrusion ratio
|
|
* and reduce to an 8 bit value.
|
|
*
|
|
* A nominal width of 1.75 and measured width of 1.73
|
|
* gives (100 * 1.75 / 1.73) for a ratio of 101 and
|
|
* a return value of 1.
|
|
*/
|
|
static int8_t sample_to_size_ratio() {
|
|
return ABS(nominal_mm - measured_mm) <= FILWIDTH_ERROR_MARGIN
|
|
? int(100.0f * nominal_mm / measured_mm) - 100 : 0;
|
|
}
|
|
|
|
// Apply a single ADC reading to the raw value
|
|
static void accumulate(const uint16_t adc) {
|
|
if (adc > 102) // Ignore ADC under 0.5 volts
|
|
accum += (uint32_t(adc) << 7) - (accum >> 7);
|
|
}
|
|
|
|
// Convert raw measurement to mm
|
|
static inline float raw_to_mm(const uint16_t v) { return v * 5.0f * RECIPROCAL(float(MAX_RAW_THERMISTOR_VALUE)); }
|
|
static inline float raw_to_mm() { return raw_to_mm(raw); }
|
|
|
|
// A scaled reading is ready
|
|
// Divide to get to 0-16384 range since we used 1/128 IIR filter approach
|
|
static inline void reading_ready() { raw = accum >> 10; }
|
|
|
|
// Update mm from the raw measurement
|
|
static inline void update_measured_mm() { measured_mm = raw_to_mm(); }
|
|
|
|
// Update ring buffer used to delay filament measurements
|
|
static inline void advance_e(const float &e_move) {
|
|
|
|
// Increment counters with the E distance
|
|
e_count += e_move;
|
|
delay_dist += e_move;
|
|
|
|
// Only get new measurements on forward E movement
|
|
if (!UNEAR_ZERO(e_count)) {
|
|
|
|
// Loop the delay distance counter (modulus by the mm length)
|
|
while (delay_dist >= MMD_MM) delay_dist -= MMD_MM;
|
|
|
|
// Convert into an index (cm) into the measurement array
|
|
index_r = int8_t(delay_dist * 0.1f);
|
|
|
|
// If the ring buffer is not full...
|
|
if (index_r != index_w) {
|
|
e_count = 0; // Reset the E movement counter
|
|
const int8_t meas_sample = sample_to_size_ratio();
|
|
do {
|
|
if (++index_w >= MMD_CM) index_w = 0; // The next unused slot
|
|
ratios[index_w] = meas_sample; // Store the measurement
|
|
} while (index_r != index_w); // More slots to fill?
|
|
}
|
|
}
|
|
}
|
|
|
|
// Dynamically set the volumetric multiplier based on the delayed width measurement.
|
|
static inline void update_volumetric() {
|
|
if (enabled) {
|
|
int8_t read_index = index_r - meas_delay_cm;
|
|
if (read_index < 0) read_index += MMD_CM; // Loop around buffer if needed
|
|
LIMIT(read_index, 0, MAX_MEASUREMENT_DELAY);
|
|
planner.apply_filament_width_sensor(ratios[read_index]);
|
|
}
|
|
}
|
|
|
|
};
|
|
|
|
extern FilamentWidthSensor filwidth;
|