-- Box Services MIB overview: -- Box Services MIB falls under fastPath MIB node of the private subtree. FASTPATH-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN -- Broadcom Corporation FASTPATH Box Services MIB -- Copyright Broadcom Corporation(2004-2008) All rights reserved. -- This SNMP Management Information Specification -- embodies Broadcom Corporation's confidential and proprietary -- intellectual property. Broadcom Corporation retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Broadcom Corporation -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC DisplayString FROM RFC1213-MIB fastPath FROM BROADCOM-REF-MIB; fastPathBoxServices MODULE-IDENTITY LAST-UPDATED "200802220000Z" -- 22 Feb 2008 12:00:00 GMT ORGANIZATION "Broadcom Corporation" CONTACT-INFO " Customer Support Postal: Broadcom Corporation 100 Perimeter Park Dr., Suite H Morrisville, NC 27560 Tel: +1 919 865 2700" DESCRIPTION "The Broadcom Private MIB for FASTPATH Box Services Feature." -- Revision history. REVISION "200802220000Z" -- 22 Feb 2008 12:00:00 GMT DESCRIPTION "Broadcom branding related changes." ::= { fastPath 43 } --************************************************************************************** -- boxServicesGroup -- -- This group provides configuration and status of the Box Services -- feature. -- --************************************************************************************** boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 } --************************************************************************************** -- Some scalars boxServicesNormalTempRangeMin OBJECT-TYPE SYNTAX INTEGER (-100..100) MAX-ACCESS read-write STATUS current DESCRIPTION " Lower boundary of normal temperature range." DEFVAL { 0 } ::= { boxServicesGroup 1 } boxServicesNormalTempRangeMax OBJECT-TYPE SYNTAX INTEGER (-100..100) MAX-ACCESS read-write STATUS current DESCRIPTION " Upper boundary of normal temperature range." DEFVAL { 45 } ::= { boxServicesGroup 2 } boxServicesTemperatureTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range" DEFVAL { enable } ::= { boxServicesGroup 3 } boxServicesPSMStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Power Supply Module state change trap." DEFVAL { enable } ::= { boxServicesGroup 4 } boxServicesFanStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Fan state change trap." DEFVAL { enable } ::= { boxServicesGroup 5 } --************************************************************************************** -- boxServicesFans boxServicesFansTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan" ::= { boxServicesGroup 6 } boxServicesFansEntry OBJECT-TYPE SYNTAX BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Fan Entry" INDEX { boxServicesFansIndex } ::= { boxServicesFansTable 1 } BoxServicesFansEntry ::= SEQUENCE { boxServicesFansIndex Integer32, boxServicesFanItemType INTEGER, boxServicesFanItemState INTEGER, boxServicesFanSpeed Integer32, boxServicesFanDutyLevel Integer32 } boxServicesFansIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of fan table entry" ::= { boxServicesFansEntry 1 } boxServicesFanItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of fan" ::= { boxServicesFansEntry 2 } boxServicesFanItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of fan" ::= { boxServicesFansEntry 3 } boxServicesFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The speed of fan" ::= { boxServicesFansEntry 4} boxServicesFanDutyLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duty level of fan, in percents" ::= { boxServicesFansEntry 5} --************************************************************************************** -- boxServicesPowSupplies boxServicesPowSuppliesTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power supply" ::= { boxServicesGroup 7 } boxServicesPowSuppliesEntry OBJECT-TYPE SYNTAX BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Power Supply Entry" INDEX { boxServicesPowSupplyIndex } ::= { boxServicesPowSuppliesTable 1 } BoxServicesPowSuppliesEntry ::= SEQUENCE { boxServicesPowSupplyIndex Integer32, boxServicesPowSupplyItemType INTEGER, boxServicesPowSupplyItemState INTEGER } boxServicesPowSupplyIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of power supply table entry" ::= { boxServicesPowSuppliesEntry 1 } boxServicesPowSupplyItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of power supply" ::= { boxServicesPowSuppliesEntry 2 } boxServicesPowSupplyItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of power supply" ::= { boxServicesPowSuppliesEntry 3 } --************************************************************************************** -- boxServicesTempSensors boxServicesTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Temperature sensor This table has been obsoleted by boxServicesStackTempSensorsTable" ::= { boxServicesGroup 8 } boxServicesTempSensorsEntry OBJECT-TYPE SYNTAX BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Sensor Entry" INDEX { boxServicesTempSensorIndex } ::= { boxServicesTempSensorsTable 1 } BoxServicesTempSensorsEntry ::= SEQUENCE { boxServicesTempSensorIndex Integer32, boxServicesTempSensorType INTEGER, boxServicesTempSensorState INTEGER, boxServicesTempSensorTemperature Integer32 } boxServicesTempSensorIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of temperature sensor table entry" ::= { boxServicesTempSensorsEntry 1 } boxServicesTempSensorType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of temperature sensor" ::= { boxServicesTempSensorsEntry 2 } boxServicesTempSensorState OBJECT-TYPE SYNTAX INTEGER { normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of temperature sensor" ::= { boxServicesTempSensorsEntry 3 } boxServicesTempSensorTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value reported by sensor" ::= { boxServicesTempSensorsEntry 4} --************************************************************************************** -- boxServicesStackTempSensors boxServicesStackTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesStackTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensor" ::= { boxServicesGroup 9 } boxServicesStackTempSensorsEntry OBJECT-TYPE SYNTAX BoxServicesStackTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Sensor Entry" INDEX { boxServicesUnitIndex, boxServicesStackTempSensorIndex } ::= { boxServicesStackTempSensorsTable 1 } BoxServicesStackTempSensorsEntry ::= SEQUENCE { boxServicesUnitIndex INTEGER, boxServicesStackTempSensorIndex Integer32, boxServicesStackTempSensorType INTEGER, boxServicesStackTempSensorState INTEGER, boxServicesStackTempSensorTemperature Integer32 } boxServicesUnitIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of a stack unit" ::= { boxServicesStackTempSensorsEntry 1 } boxServicesStackTempSensorIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of temperature sensor table entry" ::= { boxServicesStackTempSensorsEntry 2 } boxServicesStackTempSensorType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of temperature sensor" ::= { boxServicesStackTempSensorsEntry 3 } boxServicesStackTempSensorState OBJECT-TYPE SYNTAX INTEGER { normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of temperature sensor" ::= { boxServicesStackTempSensorsEntry 4 } boxServicesStackTempSensorTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value reported by sensor" ::= { boxServicesStackTempSensorsEntry 5 } --************************************************************************************** -- boxServicesNotificationsGroup -- -- This group provides notification definitions for the Box Services -- feature. -- --************************************************************************************** boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 } --************************************************************************************** -- boxServices notification definitions boxsItemStateChangeEvent OBJECT-TYPE SYNTAX INTEGER { insertion(1), removal(2), becomeoperational(3), failure(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions" ::= { boxServicesNotificationsGroup 1 } boxsTemperatureChangeEvent OBJECT-TYPE SYNTAX INTEGER { abovethreshold(1), belowthreshold(2), withinnormalrange(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)" ::= { boxServicesNotificationsGroup 2 } --************************************************************************************** -- Traps --************************************************************************************** fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 } boxsFanStateChange NOTIFICATION-TYPE OBJECTS { boxServicesFansIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when fan state change happens." ::= { fastPathBoxServicesTraps 1 } boxsPowSupplyStateChange NOTIFICATION-TYPE OBJECTS { boxServicesPowSupplyIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when power supply state change happens." ::= { fastPathBoxServicesTraps 2 } boxsTemperatureChange NOTIFICATION-TYPE OBJECTS { boxServicesTempSensorIndex, boxsTemperatureChangeEvent } STATUS current DESCRIPTION "Trap is sent when temperature is changing and crossing any of the thresholds" ::= { fastPathBoxServicesTraps 3 } END