Dell-Vendor-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks FROM RFC1155-SMI MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, IpAddress, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, RowStatus, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC; -- Dell MIB tree dell OBJECT IDENTIFIER ::= { enterprises 674 } -- Dell PowerConnect MIB tree dellLan OBJECT IDENTIFIER ::= { dell 10895 } -- Dell standard MIB tree for all future PowerConnect product. There -- are already some earlier objects registered under 10895 so that it -- is necessary to carve out this subtree under dellLan.5000 in order -- to prevent conflict with existing MIB objects. dellLanStandard OBJECT IDENTIFIER ::= { dellLan 5000 } -- Dell common and device independent MIB objects. dellLanCommon OBJECT IDENTIFIER ::= { dellLanStandard 1 } -- Dell extension MIB objects for specific technology or device. dellLanExtension OBJECT IDENTIFIER ::= { dellLanStandard 2 } powerConnectVendorMIB MODULE-IDENTITY LAST-UPDATED "201205071200Z" ORGANIZATION "Dell Inc." CONTACT-INFO "support.dell.com" DESCRIPTION "Adding new objects - Dell PPID, Revision, Express Service Code." REVISION "201205071200Z" DESCRIPTION "The private MIB module definition for the Dell PowerConnect Devices. This MIB allows PowerConnect devices to be integrated into Dell ITA management system." ::= { dellLan 3000 } EnvMonState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. " SYNTAX INTEGER { normal(1), warning(2), critical(3), shutdown(4), notPresent(5), notFunctioning(6) } dellVendorMIBObjects OBJECT IDENTIFIER ::= { powerConnectVendorMIB 1 } dellVendorNotifications OBJECT IDENTIFIER ::= { powerConnectVendorMIB 2 } hardware OBJECT IDENTIFIER ::= { dellVendorMIBObjects 2 } productIdentification OBJECT IDENTIFIER ::= { hardware 100 } productStatus OBJECT IDENTIFIER ::= { hardware 110 } -- -- -- productIdentification -- productIdentificationDisplayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of this product for display purposes." ::= { productIdentification 1} productIdentificationDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A short description of this product such as: Ethernet Router Switch." ::= { productIdentification 2} productIdentificationVendor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the product manufacturer, such as: Dell Inc." ::= { productIdentification 3 } productIdentificationVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of this product." ::= { productIdentification 4 } productIdentificationBuildNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software build number of the product." ::= { productIdentification 5 } productIdentificationURL OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The URL of the web-based application to manage this device, should the device provide one. The format of the value held by this object is: http://." ::= { productIdentification 6 } productIdentificationDeviceNetworkName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device Name." ::= { productIdentification 7 } productIdentificationPerUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF ProductIdentificationPerBoxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identification specific to product instance and, in case of stackable products, per unit. If the product is not stackable, it will be considered a stack of one unit and therefore this table will contain one conceptual row only." ::= { productIdentification 8 } productIdentificationPerUnitEntry OBJECT-TYPE SYNTAX ProductIdentificationPerBoxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This row applies to a unit in a stackable product. " INDEX { productIdentificationPerBoxIndex } ::= { productIdentificationPerUnitTable 1 } ProductIdentificationPerBoxEntry ::= SEQUENCE { productIdentificationPerBoxIndex INTEGER, productIdentificationSerialNumber DisplayString, productIdentificationAssetTag DisplayString, productIdentificationServiceTag DisplayString, productIdentificationChassisServiceTag DisplayString, productIdentificationBootromVersion DisplayString, productIdentificationPiecePartID DisplayString, productIdentificationPPIDRevision DisplayString, productIdentificationExpressServiceCode DisplayString } productIdentificationPerBoxIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the stack unit to which this conceptual row corresponds. Note that the index will be the same index as the index of a 'chassis' physical entity in the entity MIB of the product." ::= { productIdentificationPerUnitEntry 1 } productIdentificationSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the product." ::= { productIdentificationPerUnitEntry 2 } productIdentificationAssetTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Asset tag of the product." ::= { productIdentificationPerUnitEntry 3 } productIdentificationServiceTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Service tag of the product." ::= { productIdentificationPerUnitEntry 4 } productIdentificationChassisServiceTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis Service tag of the product." ::= { productIdentificationPerUnitEntry 5 } productIdentificationBootromVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The boot image version of the product." ::= { productIdentificationPerUnitEntry 6 } productIdentificationPiecePartID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) MAX-ACCESS read-only STATUS current DESCRIPTION "The piece part id of the product." ::= { productIdentificationPerUnitEntry 7 } productIdentificationPPIDRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPID revision of the product." ::= { productIdentificationPerUnitEntry 8 } productIdentificationExpressServiceCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "The express cervice code of the product." ::= { productIdentificationPerUnitEntry 9 } productIdentificationBannerMotdAckMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If enable is selected, user will be required to acknowledge the banner displayed on the console. The user would have to type 'y' or 'n' to continue to the login prompt. If n is typed, the session is terminated and no future communication is allowed on that session. However, serial connection will not get terminated if user does not enter 'y'. Use disable option to disable banner acknowledge." ::= { productIdentification 9} -- -- productStatus -- productStatusGlobalStatus OBJECT-TYPE SYNTAX INTEGER { ok(3), non-critical(4), critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the product.This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. This variable can take the following values: 3: OK If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4: Non-critical If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition. 5: Critical If at least one fan is not functional, possibly causing a dangerous warming up of the device." ::= { productStatus 1 } productStatusLastGlobalStatus OBJECT-TYPE SYNTAX INTEGER { ok(3), non-critical(4), critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status before the current status which induced an initiative to issue a global status change trap." ::= { productStatus 2 } productStatusTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The last time that the product global status has been updated. The time will be given in TimeTicks" ::= { productStatus 3 } productStatusGetTimeOut OBJECT-TYPE SYNTAX INTEGER(1..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Suggested time out value in milliseconds for how long the SNMP getter should wait while attempting to poll the product SNMP service." ::= { productStatus 4 } productStatusRefreshRate OBJECT-TYPE SYNTAX INTEGER(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Rate in seconds at which the SNMP service cached data is being updated." ::= { productStatus 5 } productStatusGeneratingTrapsFlag OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this SNMP service is generating SNMP Traps. This variable can take the following values: 1: true - The device is capable and currently configured to generate traps if necessary. 2: false - The device is not capable of generating traps. 3: disabled - The device is capable but not configured to generate traps. " ::= { productStatus 6 } productStatusEnvironment OBJECT IDENTIFIER ::= { productStatus 7} envMonFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of fan status maintained by the environmental monitor. Not Supported by Dell Modular Blade Server switches." ::= { productStatusEnvironment 1 } envMonFanStatusEntry OBJECT-TYPE SYNTAX EnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor. Not Supported by Dell Modular Blade Server switches." INDEX { envMonFanStatusIndex } ::= { envMonFanStatusTable 1 } EnvMonFanStatusEntry ::= SEQUENCE { envMonFanStatusIndex INTEGER, envMonFanStatusDescr DisplayString, envMonFanState EnvMonState, envMonFanSpeed INTEGER } envMonFanStatusIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index for the fan being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning. Not Supported by Dell Modular Blade Server switches." ::= { envMonFanStatusEntry 1 } envMonFanStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. Not Supported by Dell Modular Blade Server switches." ::= { envMonFanStatusEntry 2 } envMonFanState OBJECT-TYPE SYNTAX EnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the fan being instrumented. Not Supported by Dell Modular Blade Server switches." ::= { envMonFanStatusEntry 3 } envMonFanSpeed OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the fan being instrumented. Not Supported by Dell Modular Blade Server switches." ::= { envMonFanStatusEntry 4 } envMonSupplyStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonSupplyStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of power supply status maintained by the environmental monitor card." ::= { productStatusEnvironment 2 } envMonSupplyStatusEntry OBJECT-TYPE SYNTAX EnvMonSupplyStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card." INDEX { envMonSupplyStatusIndex } ::= { envMonSupplyStatusTable 1 } EnvMonSupplyStatusEntry ::= SEQUENCE { envMonSupplyStatusIndex INTEGER , envMonSupplyStatusDescr DisplayString, envMonSupplyState EnvMonState, envMonSupplyCurrentPower INTEGER, envMonSupplyAveragePower INTEGER, envMonSupplyAvgStartTime DateAndTime, envMonSupplySource INTEGER } envMonSupplyStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index for the power supply being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { envMonSupplyStatusEntry 1 } envMonSupplyStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { envMonSupplyStatusEntry 2 } envMonSupplyState OBJECT-TYPE SYNTAX EnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the power supply being instrumented." ::= { envMonSupplyStatusEntry 3 } envMonSupplySource OBJECT-TYPE SYNTAX INTEGER { unknown(1), ac(2), dc(3), externalPowerSupply(4), internalRedundant(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply source. unknown - Power supply source unknown ac - AC power supply dc - DC power supply externalPowerSupply - External power supply internalRedundant - Internal redundant power supply " ::= { envMonSupplyStatusEntry 4 } envMonSupplyCurrentPower OBJECT-TYPE SYNTAX INTEGER (0|1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Current power consumption of the power supply being instrumented. 0 - indicates that Current power is not available for related supply." ::= { envMonSupplyStatusEntry 5 } envMonSupplyAveragePower OBJECT-TYPE SYNTAX INTEGER (0|1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average power consumption of the power supply being instrumented. 0 - indicates that Average power is not available for related supply." ::= { envMonSupplyStatusEntry 6 } envMonSupplyAvgStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply data start. 0 - indicates that power and related start time is not available for supply." ::= { envMonSupplyStatusEntry 7 } -- -- trap definitions -- dellVendorTraps OBJECT IDENTIFIER ::= { dellVendorNotifications 1 } dellVendorTrapsPrefix OBJECT IDENTIFIER ::= { dellVendorTraps 0 } productStatusGlobalStatusChange NOTIFICATION-TYPE OBJECTS { productStatusGlobalStatus, productStatusLastGlobalStatus, productStatusTimeStamp } STATUS current DESCRIPTION "This trap is sent when the product global status changes." --#TYPE "Product Global Status Change." --#SUMMARY "The product global status has changed from %d to %d at time %d." --#ARGUMENTS {1,0,2} ::= {dellVendorTrapsPrefix 1 } END