mibs-downloader/mibs/FASTPATH-BOXSERVICES-PRIVAT...

524 lines
17 KiB
Plaintext

-- Box Services MIB overview:
-- Box Services MIB falls under fastPath MIB node of the private subtree.
FASTPATH-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
-- Broadcom Corporation FASTPATH Box Services MIB
-- Copyright Broadcom Corporation(2004-2008) All rights reserved.
-- This SNMP Management Information Specification
-- embodies Broadcom Corporation's confidential and proprietary
-- intellectual property. Broadcom Corporation retains all title
-- and ownership in the Specification including any revisions.
-- This Specification is supplied "AS IS", Broadcom Corporation
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32, Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
DisplayString FROM RFC1213-MIB
fastPath FROM BROADCOM-REF-MIB;
fastPathBoxServices MODULE-IDENTITY
LAST-UPDATED "200802220000Z" -- 22 Feb 2008 12:00:00 GMT
ORGANIZATION "Broadcom Corporation"
CONTACT-INFO
" Customer Support
Postal: Broadcom Corporation
100 Perimeter Park Dr., Suite H
Morrisville, NC 27560
Tel: +1 919 865 2700"
DESCRIPTION
"The Broadcom Private MIB for FASTPATH Box Services Feature."
-- Revision history.
REVISION
"200802220000Z" -- 22 Feb 2008 12:00:00 GMT
DESCRIPTION
"Broadcom branding related changes."
::= { fastPath 43 }
--**************************************************************************************
-- boxServicesGroup
--
-- This group provides configuration and status of the Box Services
-- feature.
--
--**************************************************************************************
boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
--**************************************************************************************
-- Some scalars
boxServicesNormalTempRangeMin OBJECT-TYPE
SYNTAX INTEGER (-100..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Lower boundary of normal temperature range."
DEFVAL { 0 }
::= { boxServicesGroup 1 }
boxServicesNormalTempRangeMax OBJECT-TYPE
SYNTAX INTEGER (-100..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Upper boundary of normal temperature range."
DEFVAL { 45 }
::= { boxServicesGroup 2 }
boxServicesTemperatureTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
DEFVAL { enable }
::= { boxServicesGroup 3 }
boxServicesPSMStateTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable Power Supply Module state change trap."
DEFVAL { enable }
::= { boxServicesGroup 4 }
boxServicesFanStateTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable Fan state change trap."
DEFVAL { enable }
::= { boxServicesGroup 5 }
--**************************************************************************************
-- boxServicesFans
boxServicesFansTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesFansEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan"
::= { boxServicesGroup 6 }
boxServicesFansEntry OBJECT-TYPE
SYNTAX BoxServicesFansEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Fan Entry"
INDEX { boxServicesFansIndex }
::= { boxServicesFansTable 1 }
BoxServicesFansEntry ::= SEQUENCE {
boxServicesFansIndex
Integer32,
boxServicesFanItemType
INTEGER,
boxServicesFanItemState
INTEGER,
boxServicesFanSpeed
Integer32,
boxServicesFanDutyLevel
Integer32
}
boxServicesFansIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of fan table entry"
::= { boxServicesFansEntry 1 }
boxServicesFanItemType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of fan"
::= { boxServicesFansEntry 2 }
boxServicesFanItemState OBJECT-TYPE
SYNTAX INTEGER {
notpresent(1),
operational(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of fan"
::= { boxServicesFansEntry 3 }
boxServicesFanSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of fan"
::= { boxServicesFansEntry 4}
boxServicesFanDutyLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duty level of fan, in percents"
::= { boxServicesFansEntry 5}
--**************************************************************************************
-- boxServicesPowSupplies
boxServicesPowSuppliesTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power supply"
::= { boxServicesGroup 7 }
boxServicesPowSuppliesEntry OBJECT-TYPE
SYNTAX BoxServicesPowSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Power Supply Entry"
INDEX { boxServicesPowSupplyIndex }
::= { boxServicesPowSuppliesTable 1 }
BoxServicesPowSuppliesEntry ::= SEQUENCE {
boxServicesPowSupplyIndex
Integer32,
boxServicesPowSupplyItemType
INTEGER,
boxServicesPowSupplyItemState
INTEGER
}
boxServicesPowSupplyIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of power supply table entry"
::= { boxServicesPowSuppliesEntry 1 }
boxServicesPowSupplyItemType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of power supply"
::= { boxServicesPowSuppliesEntry 2 }
boxServicesPowSupplyItemState OBJECT-TYPE
SYNTAX INTEGER {
notpresent(1),
operational(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of power supply"
::= { boxServicesPowSuppliesEntry 3 }
--**************************************************************************************
-- boxServicesTempSensors
boxServicesTempSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Temperature sensor
This table has been obsoleted by boxServicesStackTempSensorsTable"
::= { boxServicesGroup 8 }
boxServicesTempSensorsEntry OBJECT-TYPE
SYNTAX BoxServicesTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Temperature Sensor Entry"
INDEX { boxServicesTempSensorIndex }
::= { boxServicesTempSensorsTable 1 }
BoxServicesTempSensorsEntry ::= SEQUENCE {
boxServicesTempSensorIndex
Integer32,
boxServicesTempSensorType
INTEGER,
boxServicesTempSensorState
INTEGER,
boxServicesTempSensorTemperature
Integer32
}
boxServicesTempSensorIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of temperature sensor table entry"
::= { boxServicesTempSensorsEntry 1 }
boxServicesTempSensorType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of temperature sensor"
::= { boxServicesTempSensorsEntry 2 }
boxServicesTempSensorState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notpresent(5),
notoperational(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of temperature sensor"
::= { boxServicesTempSensorsEntry 3 }
boxServicesTempSensorTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value reported by sensor"
::= { boxServicesTempSensorsEntry 4}
--**************************************************************************************
-- boxServicesStackTempSensors
boxServicesStackTempSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesStackTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature sensor"
::= { boxServicesGroup 9 }
boxServicesStackTempSensorsEntry OBJECT-TYPE
SYNTAX BoxServicesStackTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Temperature Sensor Entry"
INDEX { boxServicesUnitIndex, boxServicesStackTempSensorIndex }
::= { boxServicesStackTempSensorsTable 1 }
BoxServicesStackTempSensorsEntry ::= SEQUENCE {
boxServicesUnitIndex
INTEGER,
boxServicesStackTempSensorIndex
Integer32,
boxServicesStackTempSensorType
INTEGER,
boxServicesStackTempSensorState
INTEGER,
boxServicesStackTempSensorTemperature
Integer32
}
boxServicesUnitIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of a stack unit"
::= { boxServicesStackTempSensorsEntry 1 }
boxServicesStackTempSensorIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of temperature sensor table entry"
::= { boxServicesStackTempSensorsEntry 2 }
boxServicesStackTempSensorType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of temperature sensor"
::= { boxServicesStackTempSensorsEntry 3 }
boxServicesStackTempSensorState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notpresent(5),
notoperational(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of temperature sensor"
::= { boxServicesStackTempSensorsEntry 4 }
boxServicesStackTempSensorTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value reported by sensor"
::= { boxServicesStackTempSensorsEntry 5 }
--**************************************************************************************
-- boxServicesNotificationsGroup
--
-- This group provides notification definitions for the Box Services
-- feature.
--
--**************************************************************************************
boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
--**************************************************************************************
-- boxServices notification definitions
boxsItemStateChangeEvent OBJECT-TYPE
SYNTAX INTEGER {
insertion(1),
removal(2),
becomeoperational(3),
failure(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This event describes states of the fan or power supply.
insertion - hot-pluggable fan or power supply was inserted
removal - hot-pluggable fan or power supply was removed
becomeoperational - fan or power supply became operational after failure state
failure - fan or power supply failure happened, i.e. it is not able to perform its functions"
::= { boxServicesNotificationsGroup 1 }
boxsTemperatureChangeEvent OBJECT-TYPE
SYNTAX INTEGER {
abovethreshold(1),
belowthreshold(2),
withinnormalrange(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This event describes change of the temperature.
To avoid flipping on boundary conditions, it is allowed to send the trap
taking into account some margin around thresholds.
abovethreshold - temperature increased and crossed upper threshold value
belowthreshold - temperature decreased and crossed lower threshold value
withinnormalrange - temperature returned to normal range (between threshold)"
::= { boxServicesNotificationsGroup 2 }
--**************************************************************************************
-- Traps
--**************************************************************************************
fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
boxsFanStateChange NOTIFICATION-TYPE
OBJECTS {
boxServicesFansIndex,
boxsItemStateChangeEvent
}
STATUS current
DESCRIPTION
"Trap is sent when fan state change happens."
::= { fastPathBoxServicesTraps 1 }
boxsPowSupplyStateChange NOTIFICATION-TYPE
OBJECTS {
boxServicesPowSupplyIndex,
boxsItemStateChangeEvent
}
STATUS current
DESCRIPTION
"Trap is sent when power supply state change happens."
::= { fastPathBoxServicesTraps 2 }
boxsTemperatureChange NOTIFICATION-TYPE
OBJECTS {
boxServicesTempSensorIndex,
boxsTemperatureChangeEvent
}
STATUS current
DESCRIPTION
"Trap is sent when temperature is changing and crossing any of the thresholds"
::= { fastPathBoxServicesTraps 3 }
END