Commit Graph

470 Commits

Author SHA1 Message Date
Scott Lahteine
11bbcfd69e
Update emergency_parser for 2.0.x parity (#10530) 2018-04-25 22:42:43 -05:00
Scott Lahteine
ad3b95c8ea Fix current_temperature_chamber compile error
Fix #10505
2018-04-24 07:53:45 -05:00
Scott Lahteine
51004e003d
Proper AVR preemptive interrupt handling (#10501)
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-04-23 20:47:31 -05:00
Scott Lahteine
b19d8182c1
Add HAS_HEATED_BED conditional (#10494) 2018-04-22 23:40:49 -05:00
Lenbok
0aa833fe6c Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:44 -05:00
Scott Lahteine
7ff70d7adb
Improve heating/cooling LCD messages (#10296) 2018-04-04 19:13:48 -05:00
AnHardt
105c81217c Make 2 constants in autotune configurable
But hidden, since changes are rarely needed.
2018-03-20 16:39:27 -05:00
AnHardt
3911c38d5e Fix autotune Thermal Protection
When `THERMAL_PROTECTION_BED` is off but `THERMAL_PROTECTION_HOTENDS` is on, `watch_temp_period` and `watch_temp_increase` are initialized with the values for `THERMAL_PROTECTION_HOTENDS`. Later it is not tested if these values are for the bed or the nozzles.

- Add test.
- Name a constant.

Fix for #10150
2018-03-20 16:38:38 -05:00
Scott Lahteine
f7de05e50c General spacing cleanup 2018-03-17 16:51:34 -05:00
Scott Lahteine
dc98ee553f Fix compiler warning for ANALOG_SELECT 2018-03-13 22:33:56 -05:00
Scott Lahteine
2bf1bbf399 Add HAS_TEMP_SENSOR conditional 2018-03-07 01:58:31 -06:00
Scott Lahteine
f0d8d76f68
Use static classes for job timers (#9940) 2018-03-04 22:52:25 -06:00
Scott Lahteine
b6fa55aa37
Fix: M112 calling kill from interrupt (#9922)
Fix #9906
2018-03-03 23:13:53 -06:00
Scott Lahteine
016bd86c28
Add MSG_THERMAL_RUNAWAY_BED (#9695) 2018-02-18 02:24:08 -06:00
Bob-the-Kuhn
d413781b98 Fix setPwmFrequency declaration (#9687) 2018-02-17 23:19:49 -06:00
Scott Lahteine
9dd8a49f82 Add pin_t to Marln 1.1 branch 2018-02-08 21:01:41 -06:00
Scott Lahteine
36ba754842 More reliable PROBING_HEATERS_OFF with BED_LIMIT_SWITCHING 2018-02-08 21:01:41 -06:00
Christopher Reimer
254417e8b0 Enable and disable power supply automatically 2018-02-06 00:20:33 -06:00
Scott Lahteine
3ab4736ac9 Move some strings to PROGMEM 2018-01-23 23:50:42 -06:00
Scott Lahteine
6ed2840615
Use delay() in serial temp report 2018-01-20 14:12:30 -06:00
Scott Lahteine
5129eb1d43 More reliable temperature serial output? 2018-01-15 00:44:55 -06:00
revilor
aec65112b5 Fix for issue #9005, #8942 - Bed PID autotuning (#9037) 2018-01-04 03:26:29 -06:00
Scott Lahteine
01e3ccfd69 Cleanup, commentary of M303 pid tuning code 2018-01-03 20:48:43 -06:00
Scott Lahteine
9de9e37539 Some temperature code cleanup 2018-01-01 18:03:43 -06:00
Scott Lahteine
ab7f1a0608 A single setting to validate filament width 2017-12-19 21:34:30 -06:00
Scott Lahteine
ce6a691999 Fix #8839 - filament width sensor 2017-12-19 18:24:56 -06:00
Dave Johnson
817eb5a5ba Missing HAS_HEAT_BED conditional
Fixes issue found in #8779
2017-12-15 11:36:36 -08:00
Scott Lahteine
f36f91dfb5 Reduce code with no heated bed 2017-12-13 17:59:17 -06:00
Scott Lahteine
8519451161 Comment, improve filament width sensor 2017-12-13 02:35:23 -06:00
Scott Lahteine
1063b3b2b8 Changes for parity with 2.0.x 2017-12-06 21:19:17 -06:00
Scott Lahteine
5d01a2f467 Move temperature reporting to Temperature class 2017-12-06 21:12:55 -06:00
Scott Lahteine
794f8f1329 Update K1 => PID_K1 2017-12-05 19:59:01 -06:00
Scott Lahteine
38e5883d44 Apply const to thermal_runaway_protection args 2017-12-01 19:43:31 -06:00
Scott Lahteine
bf6a1816b4 Display volumetric ratio in terms of E mm 2017-11-18 07:03:18 -06:00
Thomas Moore
97c19de8b9 Fix PlatformIO dependencies 2017-11-16 15:16:21 -06:00
RowanMeara
10e366ebd7 Change dithering behavior to intended. 2017-11-14 00:36:35 -08:00
Rowan Meara
d2df00bfca [1.1.x] Fix compilation warnings (#8395)
* Fix up Travis CI and compile warnings/errors

* No ULTRA_LCD with REPRAP_DISCOUNT_SMART_CONTROLLER

* No point in setting all the endstop plugs
2017-11-13 04:18:19 -06:00
Scott Lahteine
3293823642 Add pre-calculated planner.e_factor 2017-11-10 20:09:59 -06:00
Scott Lahteine
b0ff3a4c6d Cleanup around updatePID 2017-11-10 19:17:46 -06:00
Rowan Meara
094bebcc2d [1.1.x] Update Thermal Protection Documentation (#8282)
* Fix thermal protection documentation.

Even before the recent thermal protection changes, the documentation of
the thermal protection feature in the config files did not match the
implementation.  I fixed the documentation and reconciled the M303
implementation with the documentation.

* Applied documentation changes to sample config files

* Renamed hysteresis to watch_temp_increase

* Added gcodes back into documentation.
2017-11-07 15:52:28 -06:00
Scott Lahteine
44edffa0a9 Fix SLOW_PWM_HEATERS, issues already patched in 2.0.x 2017-11-06 22:40:44 -06:00
Scott Lahteine
524f4ee0cf Tweak to M330 thermal protection 2017-11-03 03:57:11 -05:00
Scott Lahteine
193a0e9273
pid_autotune parity with 2.0.x 2017-11-03 03:26:47 -05:00
Rowan Meara
39cc36d3f1 [1.1.x] M303 thermal runaway protection (#8209)
* Added M303 thermal runaway protection

Currently, thermal runaway protection is not available during M303.
Therefore, if someone plugs the thermistors in incorrectly and goes to
autotune their printer, the printer temperature could runaway and damage
could occur.

* Replace removed line, clarifying its logic
2017-11-03 03:16:39 -05:00
Rowan Meara
9850ba0cbd [1.1.x] Fix M303 thermal protection #8103 (#8126)
* Fixed M303 thermal protection

The temperature sanity checking logic was not being applied during M303
(pid autotuning) because instead of setting a target temperature, it
directly manipulated the pwm values.  When PIDTEMP/PIDTEMPBED is
enabled, PWM values rather than the target temperature determine whether
the heater is on.  I changed this to look directly at the PWM amount
when pid is enabled.

* Turn off heaters on M303 error

Currently, PID autotuning stops if it overshoots the temperature by 20C
or if if the temperature does not change for 20 minutes and it times
out.  I added calls to disable the heaters in these scenarios.

* Removed unnecessary if statement.

Added changes suggested by GMagician.

* Update temperature.cpp

* Update temperature.cpp

* Update temperature.cpp
2017-10-29 04:34:47 -05:00
Scott Lahteine
662105c1b6 ADC sensor fix inspired by 'Evgen2' on Twitter 2017-10-14 02:39:13 -05:00
Scott Lahteine
bbb94b8f68 babystepping tweak 2017-09-27 00:12:20 -05:00
Scott Lahteine
e337df2e98 Miscellaneous tweaks to serial outputs, code cleanups 2017-08-23 18:32:58 -05:00
Scott Lahteine
b0173ccdb9 Drop extra initializers for vars initialized by EEPROM code 2017-07-20 22:57:49 -05:00
João Brázio
2065591daf Add support for BQ heated bed kit with Hephestos 2 2017-07-07 03:10:38 -05:00