Scott Lahteine
27f244ba2c
Support MAX31855 as Temperature Sensor -3
2016-03-10 02:49:54 -08:00
Scott Lahteine
ff13070b59
Use _BV macros, patch up others
2016-03-06 05:51:55 -08:00
Scott Lahteine
209f5f21e0
Use macros where possible
...
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
2016-03-06 05:51:55 -08:00
Scott Lahteine
3a3d358df9
Fix Printrboard with LCD (redo)
...
Based on #2860 - rebased for RCBugFix
2016-03-05 22:13:00 -08:00
Blue-Marlin
0631541166
Fix disable_all_heaters() for MAX6675
2016-03-02 14:17:23 +01:00
AnHardt
57da1b8497
Host parseble output for M109, M190 and M303
...
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
2015-12-07 15:37:53 -06:00
Richard Wackerbarth
956418c674
Kc is also a multi-PID parameter
2015-11-23 06:08:01 -06:00
Scott Lahteine
dbd4c17096
Init Kp, Ki, Kd to 0
2015-11-12 00:03:22 -06:00
Scott Lahteine
b4af4441c5
Clean up watchdog impl.
2015-11-12 00:03:22 -06:00
Scott Lahteine
9bdab4f3a8
Clean up "else" and other spacing
2015-11-12 00:03:21 -06:00
Richard Wackerbarth
25d636c9e0
Compiler issues (PR#2696)
2015-11-11 23:52:11 -06:00
AnHardt
47401ec97b
MSG_EXTRUDER_SWITCHED_OFF was renamed to MSG_REDUNDANCY
...
in language.h, but was not renamed here. If TEMP_SENSOR_1 is enabled as redundant then
an error is thrown that MSG_EXTRUDER_SWITCHED_OFF is not defined.
Originaly by @12dstring
2015-10-08 10:45:11 -05:00
Scott Lahteine
0c7f7ebcfb
Styling adjustments (PR#2668 & PR#2670)
...
Keep "astyled" reformatting
2015-10-03 22:02:45 -05:00
Scott Lahteine
bc50db9cf6
Implement PID_ADD_EXTRUSION_RATE
2015-09-12 07:53:20 -05:00
Scott Lahteine
51e89a269c
Overridable Options - Part 9 (PR#2561)
...
Apply `ENABLED` / `DISABLED` macros to temperature-related files.
2015-07-31 01:05:55 -05:00
AnHardt
d17f7ebc8a
Multiply WATCH_TEMP_PERIOD by 1000UL (PR#2535)
...
instead of 1000. Else we get errors with times over 32 seconds.
2015-07-27 20:30:53 -05:00
Scott Lahteine
e4c01f1c7e
Simplify init with ARRAY_BY_EXTRUDERS1 macro (PR#2507)
2015-07-26 20:40:27 -05:00
Scott Lahteine
77e80ef367
Require extruders for thermal code
2015-07-16 16:36:30 -05:00
Scott Lahteine
3bde4f4855
Require temp sensor for bed thermal protection
2015-07-16 16:36:30 -05:00
ayberkozgur
7268d46508
Always calculate extruder temperature PID d term (PR#2432)
2015-07-13 13:22:26 -05:00
Scott Lahteine
a274769f4f
Clean up spacing and comments
...
Also clean up some trailing spaces in a few other sources
2015-06-15 20:20:31 -05:00
Scott Lahteine
1d94d098bf
Formatting tweaks as part of fixing issue 1497
2015-06-14 19:57:27 -05:00
Scott Lahteine
e602c28ad9
Set auto fan pins to OUTPUT during init
...
Fixes the problem of these pins being left in INPUT state, as described
in #1497
2015-06-14 19:57:27 -05:00
MagoKimbra
eb81982fcd
Fix error next command in autotune (PR#2274)
...
Now send only temperature for T or B, but not send OK.
Host interprets the line to show the right temperature, but not in
response to M105 then stop and send commands until it ends the autotune.
2015-06-12 07:10:38 -05:00
AnHardt
b1404a0743
fix thermal protection state machine target temp. V2
...
If the target temperature is changed then it would always stay in the reset state.
Thanks to @tonokip.
Replaces #2119
2015-06-02 12:26:21 +02:00
Jonathan Bastien-Filiatrault
e86f2342c0
Separate the maximum integral power for the bed from PID_INTEGRAL_DRIVE_MAX / PID_MAX.
...
My PID_INTEGRAL_DRIVE_MAX was at 96, which was insufficient for my bed
to reach its intended temperature. The head requires a low maximum power since
I run on 24 volts and it has a somewhat low thermal mass.
2015-05-28 11:48:04 -04:00
AnHardt
da246f5cb1
Activate BED_MINTEMP error.
...
And call _temp_error() directly for ERR_MAXTEMP_BED to avoid the only one time use of bed_max_temp_error().
Includes #2156 .
2015-05-25 13:23:19 +02:00
AnHardt
959da98d8e
Call kill() only once when triggered by a temperature error
...
to avoid stack overflow when called from interrupt.
Some clean up for calls of disable_all_heaters().
'disable_all_heaters()' is called in kill() and again when 'killed' is already set inside _temp_error().
2015-05-25 12:44:03 +02:00
Scott Lahteine
063881b5bd
Fix a couple of doubled semicolons
2015-05-21 18:15:29 -07:00
Scott Lahteine
00716d0ca0
Small start_watching_heater adjustment
2015-05-21 16:44:49 -07:00
AnHardt
4422365a53
Merge branch 'Development' of https://github.com/MarlinFirmware/Marlin into _temp_error
2015-05-20 23:34:39 +02:00
AnHardt
4113762062
Merge pull request #2130 from AnHardt/kill2
...
Add a string parameter to kill()
2015-05-20 23:32:51 +02:00
AnHardt
120d4c7a8c
Merge remote-tracking branch 'origin/kill2' into _temp_error
2015-05-20 21:25:32 +02:00
AnHardt
cb6e82dc60
Change from kill() to kill(const char *)
...
in temperature.cpp
2015-05-20 21:22:48 +02:00
AnHardt
9d13942278
Use new kill() with parameter.
2015-05-20 21:18:52 +02:00
AnHardt
2990c6c45f
Use new kill_() for _temp_error()
...
instead of stop(). We really want to require a reset and no chance to set a new temperature.
2015-05-20 14:03:14 +02:00
AnHardt
70163dafb9
Use _temp_error() for all errors thrown by different mechanisms
...
Now ending in an endless loop.
Tidy up the output format.
We now get:
ERRORTEXT ", system stopped! Heater_ID: " HEATERID
Where ERRORTEXT can be:
"Heating failed"
"Thermal Runaway"
"MAXTEMP triggered"
"MINTEMP triggered"
and soon
"Thermal Jump"
HEATERID can be
0, 1, 2 ,3 , "bed"
This messages are always followed by the common:
"Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
2015-05-18 20:26:25 +02:00
AnHardt
97ca1b3f4d
Name magic value 20 to MAX_OVERSHOOT_PID_AUTOTUNE
...
to make it better findable.
2015-05-18 14:15:29 +02:00
Scott Lahteine
f65833931d
Formatting tweaks
2015-05-13 02:02:19 -07:00
Scott Lahteine
d693e0f378
Use WATCH_TEMP_INCREASE + TEMP_HYSTERESIS + 1 as difference limit
2015-05-12 18:30:38 -07:00
Scott Lahteine
6697a8f375
Watch the heater a little longer
2015-05-12 18:22:47 -07:00
Scott Lahteine
5693a6e3c9
Fix heating error message
2015-05-12 18:17:13 -07:00
Scott Lahteine
8332a15899
Fix testing of runaway options in temperature.cpp
2015-05-10 23:03:24 -07:00
Scott Lahteine
2445ae3d3a
Combine thermal runaway and watch-period
...
- Make thermal protection for all hotends and/or bed into simple
switches
- Now enable `WATCH_TEMP_PERIOD` when `THERMAL_PROTECTION_HOTENDS` is
enabled
- Move detailed thermal parameters to `Configuration_adv.h`
- Add sanity checks to warn about old configurations
- Change `WATCH_TEMP_PERIOD` to seconds instead of milliseconds
2015-05-10 22:52:01 -07:00
Scott Lahteine
9b3d4380d3
Only watch the heater that was set
2015-05-10 20:26:45 -07:00
Scott Lahteine
28c87ec81b
Disable all heaters on temp error
2015-05-08 23:17:25 -07:00
Scott Lahteine
54deb9eea3
Enable WATCH_TEMP_PERIOD by default
2015-05-08 22:36:02 -07:00
Scott Lahteine
deedb00c18
Document WATCH_TEMP_PERIOD
2015-05-08 22:25:51 -07:00
Scott Lahteine
a120bf3fe4
Latest upstream commits
2015-04-27 22:40:19 -07:00
Scott Lahteine
ae53b3cdc3
Fix the M303 S-1 report text
2015-04-27 22:25:00 -07:00