- can be augmented in the future to enable for other leveling systems
Quite simple, but did not want to modify `G1` as the additional checking would slow it down.
Tested & working.
- fix broken `M421` due to less-than-careful optimization
- add HOME_AFTER_DEACTIVATE define to advanced config so not everyone has to rehome after steppers are deactivated
- misc. cleanups (remove unused label, unused variables)
- Add crc16 utility function
- Implement CRC16 for config store, remove old checksum, increment layout version
- Move UBL mesh store/load to MarlinSettings; increment UBL_VERSION
- Begin to lay out MAT structure, prototype functions, etc.
- Rename ubl.state.eeprom_storage_slot to .storage_slot
- Misc. optimization
- Cleanup/standardize/improve some messages
This is a work in progress!
* M421 Mesh Point Offset and misc. UBL clean up
Allow M421 to accept an offset as well as absolute value for a specified
mesh point.
And misc. UBL clean up to reduce redundent code.
* Better error checking for M421
* Fix M421 Y index bug
I just noticed.... We've had a Y index bug for who knows how long?
* Restore LSF functionality
Some of the typo's persisted... Hopefully this gets them all fixed.
* Restore user's expectations of how G28 should behave
* Allow Nozzle size control with ornery host programs
- rename to PROBING_HEATERS_OFF
- move heater pausing functionality into thermalManager
- add variables, pause(), ispaused(), other functions
- add fan pausing functionality -> PROBING_FANS_OFF
- add probing_pause() wrapper
- move pausing into do_homing_move() and do_probe_move() to minimize quiet time and so other probe types can benefit
- example configs
When both lowering and recovery are performed using the same "prepare_move_to_destination()" the extruder recovery feedrate ends up being ignored and, instead, is only capped by either the maximum e-speed or the time it takes to perform the z-lowering.
Performing the two moves separately from each other ensures a correct recovery feedrate.
add BLTouch-related messages in english and (rusty) french;
add missing endstops.h in ultralcd.cpp;
fix misc. compiler warnings;
fix lsf_reset - ZERO macro can't handle a pointer as it would only memset the size of the pointer, not the size of the entire struct
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
The electro-magnetic interference from the bed and nozzle are affecting
the BL-Touch repeatability for some users. This problem can be helped
by shutting down the heaters during the actual probe event and then
quickly turning them back on.
Because this code is messing with the heaters, it is written in a
paranoid manner. It only turns the heaters back on if everything is
EXACTLY as it expects things to be. The BL-Touch probe must have been
put into a deployed state less than 20 seconds prior, or the stow()
function will NOT turn the heaters on.
This code has been tested and works for both G28 and probing functions.
Giving a negative number of probe points disables the tower angle
correction calibration ('4point' instead of '7point' solution)
EEPROM version updated
* relocated ubl state to config. store:
* removed a number of ubl state variables and padding which were largely unused - saved 58 bytes of both SRAM and EEPROM;
* modified ubl sanity_check - no longer checks removed state variables that were otherwise unused, where checking didn't seem to accomplish anything, ultimately;
* removed pre_initialized state, saving 64 bytes of SRAM;
* removed automatic saving of UBL state after UBL activation/deactivation;
* consolidated multiple GRID_MAX_POINTS_X/Y to 'Global Leveling' section of EEPROM;
* minor update to G29 Sx notes/instructions;
* renamed mesh load and save parameter to 'slot' from 'm' for clarity;