This is an initial cut for feedback.
Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?
Chamber temperatures are not reported on the LCD in any way.
When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.
As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
Some users may prefer to hide the position updates on the `LIGHTWEIGHT_UI` altogether. This leads to an even less cluttered display (it also saves on SPI traffic and one byte of RAM).
- This status screen uses the ST7920 character generator to greatly reduce SPI traffic and MCU load when updating the status screen.
- Has been tested with the RepRapDiscount Full Graphics Smart Controller but should work with any LCD that uses an ST7920 or fully compatible controller.
Updating I2C position encoders to enable babystepping and Babystep XY when using the ecm microstep correction method. Also changed default method to ECM microstep.
Implemented synchronization message output for NanoDLP printers (nanodlp.com).
If optional feature is enabled in `Configuration_adv.h`, Marlin will ouput "Z_move_comp" string to serial after completing any G0/G1 Z-axis movements. This feature patched on previous versions(1.0) is used by NanoDLP to synchronize Z-axis movement with projector exposure in DLP stereolithography printers.
* Fix thermal protection documentation.
Even before the recent thermal protection changes, the documentation of
the thermal protection feature in the config files did not match the
implementation. I fixed the documentation and reconciled the M303
implementation with the documentation.
* Applied documentation changes to sample config files
* Renamed hysteresis to watch_temp_increase
* Added gcodes back into documentation.