Made the double touch portion a conditional compile based on the PROBE_DOUBLE_TOUCH flag. ============================================== Bugfix The current G38 only stopped a move if it involved the Z axis. Moved all the G38 code to it's own section and put it where it would always be executed no matter what axis was moving or if the endstop was enabled. Also added a comment to configuration_adv to alert the user the double tap had to be turned on. ============================================== Change G38 back to using Z_MIN_PROBE There's no Z_MIN endstop if Z_DUAL_ENDSTOPS is enabled and you have them set to the top of the gantry. G38 started out as using the Z_MIN_PROBE pin. I don't remember why we changed it to the Z_MIN endstop. |
||
---|---|---|
.. | ||
_Bootscreen.h | ||
Configuration_adv.h | ||
Configuration.h | ||
README.md |
Example Configuration for BQ Hephestos 2
This configuration file is based on the original configuration file shipped with the heavily modified Marlin fork by BQ. The original firmware and configuration file can be found at BQ Github repository.
NOTE: The look and feel of the Hephestos 2 while navigating the LCD menu will change by using the original Marlin firmware.
Changelog
- 2016/03/01 - Initial release
- 2016/03/21 - Activated 4-point auto leveling by default Updated miscellaneous z-probe values
- 2016/06/21 - Disabled hot bed related options Activated software endstops SD printing now disables the heater when finished
- 2016/07/13 - Update the
DEFAULT_AXIS_STEPS_PER_UNIT
for the Z axis Increased theDEFAULT_XYJERK
- 2016/12/13 - Configuration updated.