- Add `Conditionals.h` with calculated configuration values
- Add `SanityCheck.h` with checks for configuration errors
- Remove equivalent code from all configurations
- Move error checks from some sources to `SanityCheck.h` also
- Fix initialization of count_direction in stepper.cpp
When one hit "Stop Print" option in LCD menu, the command buffer was not
cleared. The printer keep moving until the buffer has been emptied.
Actually I could not clear the command buffer as well.. I don't know
why, it doesnt work as expected.
I need to implement a routine inside Stepper ISR to handle such
situation.
While bunting an other bug I stumbled across:
ultralcd.cpp:1250: warning: comparison between signed and unsigned
integer expressions
Changed to the type of lcd_next_update_millis.
- Add BIT and TEST macros
- Add _APPLY_ macros to stepper.cpp to help with consolidation
- Consolidate code in stepper.cpp using macros
- Apply standards in stepper.cpp
- Use >= 0 instead of > -1 as a better semantic
- Replace DUAL_Y_CARRIAGE with Y_DUAL_STEPPER_DRIVERS
Added option to set Travel Acceleration (non printing moves).
The M204 options was a non sense (S for printing moves and T for retract
moves).
It has been changed to:
P = Printing moves
R = Retract only (no X, Y, Z) moves
T = Travel (non
printing) moves
I will add this info o G-Code wiki in reprap.org. I also advise to put
this info in Marlin next version changelog.
- Fix bug in lcd_control_temperature_menu
- Remove test menu-item left in from multi-line command feature
- Replace literals with translatable strings
- Reduce lcd_preheat code redundancy
- Reduce menu macro redundancy
- Clean up formatting
Introduced lcd_strlen() and lcd_strlen_P().
Replaced the old functions where necessary.
Reworked language_ru.h.
Speeded up test for zero length string in cardreader.cpp
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
* Depending on extruder count, will add menu items for ultralcd to edit
individual PID parameters for each extruder
* Added menu items to each language_xx.h
* Builds OK, but recommend testing with typical LCD