Commit Graph

6 Commits

Author SHA1 Message Date
Scott Lahteine
2445ae3d3a Combine thermal runaway and watch-period
- Make thermal protection for all hotends and/or bed into simple
switches
- Now enable `WATCH_TEMP_PERIOD` when `THERMAL_PROTECTION_HOTENDS` is
enabled
- Move detailed thermal parameters to `Configuration_adv.h`
- Add sanity checks to warn about old configurations
- Change `WATCH_TEMP_PERIOD` to seconds instead of milliseconds
2015-05-10 22:52:01 -07:00
Scott Lahteine
79106638a8 Fix documentation of heating sanity check 2015-05-08 22:50:08 -07:00
Scott Lahteine
6110494a56 Change default to 4°C in 16s 2015-05-08 22:41:12 -07:00
Scott Lahteine
deedb00c18 Document WATCH_TEMP_PERIOD 2015-05-08 22:25:51 -07:00
Scott Lahteine
181ccc884c Edit thermal runaway description 2015-05-07 20:46:03 -07:00
Brian Gilbert
1285784a49 Add Boots Industries V2.5 example configuration 2015-05-04 09:10:42 +10:00