When probing PCB´s I had the problem that i needed auto-leveling for specific areas (it´s never the same size).
Not much code, but very useful.
Now I use simply G29 L5 R55 F5 B35 P3 to probe a 4x6cm PCB before milling.
I used int for values... might be wrong...
I hope this time I got the right development tree. (tried first with https://github.com/MarlinFirmware/Marlin/pull/1130/commits)
I've insert the define and pointer entries for the Viki 2 and miniViki
from Panucatt in all of the example configs and main config. With these
additions and with pins done in the old single pin.h style...I was able
to get the display working fine save for needing to turn Delta Segments
per Second down. But that's a common graphics lcd issue being looked
into right now.
I need assistance in understanding how the new divided pins files fit
together because my previous attempts at trying to get it to work
appropriately didn't seem successful. This originally came from trying
to find out how to swap the XYZ Min and Max Endstop pins in the Azteeg
X3 Pro. It only comes with one set of connectors and they're Min
Endstops. My previous experience didn't turn out well trying to tell the
firmware to home to the Min Endstops so the best solution I found was to
swap the pins in the firmware. If I'm missing a conflict with a setup
other than delta please let me know, but it makes sense in my setup.
Update ConfigurationStore to always write dummy values for disabled
options, including FWRETRACT, DELTA, and SCARA. Update the EEPROM
version to “V15.” Also fixes a buffer overrun with axis_scaling in
Config_ResetDefault.
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
This change introduces an improvement to G29 command on Marlin.
Auto bed leveling operation's reliability is based on the repeatability of the Z-probe switch and the servo. This change introduces an option to G29 command. When the G29 command is sent with an "e" option, during auto bed levelling the servo is not retracted between probes which decreases the bias on auto bed levelling resulting from servo.
G29 command does the auto bed probing as it is.
G29 E command engages the servo on first probing point, probes all points and retracts the servo after probing the last point.
Please comment your opinions, test on your printer and check the code on a programmer's perspective. (I am not a good programmer.)
* Variables Kp, Ki, Kd, Kc now arrays of size EXTRUDERS
* M301 gains (optional, default=0) E parameter to define which
extruder's settings to modify. Tested, works with Repetier Host's EEPROM
config window, albeit only reads/updates settings for E0.
* All Kp, Ki, Kd, Kc parameters saved in EEPROM (version now v14), up to
3 extruders supported (same as Marlin in general)
try, try again.
If 'OK' is garbled on sending PC won't receive it. Both machines will
wait on each other forever. This resends OK if nothing is heard from PC
for a while to avoid this bad case.
void manage_inactivity(bool ignore_stepper_queue=false)
standard is false so it is not necessary to change additional code. this
change should be better, hopefully nophead like this :)
- Fixed issue when BAL area probing is shorter than it should be for
grid probing
- Warning when BAL activated with Delta Kinematics
- Fix XY_TRAVEL_SPEED when homing Z axis
in
G0 to G3 were previously acknowledged in the get_command method, causing
them to be possibly acknowledged before commands coming after them that
were acknowledged in process_commands.
This patch fixes this, moving the acknowledgement of G0 to G3 to the
process_commands method as well. These commands are therefore no
longer acknowledged when the enter the cmd_buffer but instead only
acknowledged when the enter the plan_buffer.
Guaranteeing that commands are acknowledged in the same order in which
they were received by the firmware allows host software to be able to
track the life cycle of commands and such a better management of the
firmware's serial buffers as well as better internal command processing
and response parsing without having to depend on throwing an epic
amount of regular expressions against each line received back from the
firmware.
FixesErikZalm/Marlin#1147