Commit Graph

824 Commits

Author SHA1 Message Date
Scott Lahteine
38b0082bf2 Additional tweaks to M42 exit conditions 2016-03-19 03:10:18 -07:00
Scott Lahteine
4bbea5124d Support for multiple PWM fans 2016-03-19 03:10:18 -07:00
Scott Lahteine
637cc03686 Fix M109 so it won't wait for cooling
Addressing issue #2767
2016-03-19 03:00:58 -07:00
Scott Lahteine
4634feaeab Merge pull request #3012 from thinkyhead/fix_command_injection
Use a serial line buffer to prevent queue corruption
2016-03-19 01:43:54 -07:00
Scott Lahteine
963a92ceda Patch idle forevermore 2016-03-18 22:38:35 -07:00
Scott Lahteine
7ec7bb31c4 Send a Busy signal to hosts during long processes, wait for input, etc
If Marlin is blocking the serial input or command queue for any length
of time (for example more than 2 seconds), it needs to send a message
to serial out to inform the host that it is busy. Marlin should only
send these messages out when busy, and preferably not when trying to
print formatted output.
2016-03-18 22:38:35 -07:00
Scott Lahteine
80277cc9c8 drain_queued_commands_P now returns true if there are more 2016-03-18 17:56:48 -07:00
Scott Lahteine
8fe7420310 Use a separate serial line buffer 2016-03-18 16:46:20 -07:00
Scott Lahteine
7d25c107a8 Merge pull request #3149 from esenapaj/patch-1
suppress warnings
2016-03-18 15:40:14 -07:00
Scott Lahteine
e8fa843c2d Merge pull request #3164 from epatel/epatel/RCBugFix
Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z
2016-03-16 02:40:54 -07:00
Scott Lahteine
d7c6fd5c2f Merge pull request #3146 from thinkyhead/rc_enabled_true_false
Support "true" and "false" in the ENABLED macro
2016-03-15 17:35:55 -07:00
Edward Patel
cb0dbfa3b5 Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z 2016-03-16 01:26:00 +01:00
Scott Lahteine
6e1bc03d3b Additional wrapping for #3140 2016-03-15 01:18:58 -07:00
Scott Lahteine
1c384930f3 Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
Wrap macros to prevent bad expansions
2016-03-15 00:25:34 -07:00
esenapaj
a4314c4907 Use local variable in recalc_delta_settings()
diagonal_rod hadn't been used anywhere.
2016-03-15 06:47:27 +09:00
esenapaj
8de7a6f9b1 suppress warnings 2016-03-15 06:34:02 +09:00
Scott Lahteine
4b648793f2 Use ENABLED with DISABLE_[INACTIVE_][XYZ] 2016-03-13 22:15:45 -07:00
Scott Lahteine
3f5fbbd398 Merge pull request #3124 from jbrazio/bugfix/update-g29-auto-level-bed-topography
Update the bed topography output done by G29
2016-03-13 03:51:43 -07:00
Scott Lahteine
f9ded2a7c4 Wrap macros to prevent bad expansions 2016-03-12 22:38:55 -08:00
jbrazio
1981e53d68 M109 R option if misused could cause a wait-forever situation 2016-03-12 06:24:24 +00:00
João Brázio
4d4a842cfb Update the bed topography output done by G29 2016-03-10 13:24:17 +00:00
AnHardt
fd5414c6ea Z_RAISE_BEFORE_HOMING -> MIN_Z_HEIGHT_FOR_HOMING
rebased
corrected spelling
changed to #elif for error

Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
2016-03-08 17:50:23 +01:00
Scott Lahteine
b7928a000a Merge pull request #3108 from AnHardt/M110+
M110 and M29 rework
2016-03-08 03:54:07 -08:00
Scott Lahteine
5cba0b4187 Merge pull request #3111 from thinkyhead/rc_drop_old_condition
Drop obsolete test for leading "N"
2016-03-08 03:07:25 -08:00
Scott Lahteine
302d1bfbc4 Drop obsolete test for leading "N" 2016-03-08 02:25:11 -08:00
AnHardt
37b857e8ec M110 ang M29 rework
Add 'ok' output for G29 actually closing the file.
Handle M110 when received without linenumber/checksumm.
2016-03-07 22:27:01 +01:00
Scott Lahteine
fac85f6fa1 Merge pull request #3102 from jbrazio/bugfix-g28-multiple-z-movements
Bugfix: G28 was lifting Z-axis multiple times
2016-03-07 03:52:00 -08:00
jbrazio
642e3699ce Z-axis was being lift multiple times if Z_SAFE_HOMING was enabled and Z_RAISE_BEFORE_HOMING was greater than zero 2016-03-07 03:49:11 +00:00
Scott Lahteine
501f63802a Merge pull request #3077 from Blue-Marlin/watchdogreset-in-kill
Add Watchdog timer reset in kill()
2016-03-06 16:21:39 -08:00
Scott Lahteine
ef68c1910c Check that the temperature is close to target 2016-03-06 05:51:56 -08:00
Scott Lahteine
ea9fd1200b Fix M109 so it won't wait for cooling
Addressing issue #2767
2016-03-06 05:51:56 -08:00
Scott Lahteine
ff13070b59 Use _BV macros, patch up others 2016-03-06 05:51:55 -08:00
Scott Lahteine
209f5f21e0 Use macros where possible
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
2016-03-06 05:51:55 -08:00
Scott Lahteine
6e64895c30 Merge pull request #3001 from AlwaysTinkering/RCBugFix
Rc bug fix - Fix for issue #2931
2016-03-06 00:20:29 -08:00
Scott Lahteine
34b8b9f0f5 Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
Add CORE support to st_get_position_mm (and elsewhere)
2016-03-06 00:17:03 -08:00
Scott Lahteine
3a3d358df9 Fix Printrboard with LCD (redo)
Based on #2860 - rebased for RCBugFix
2016-03-05 22:13:00 -08:00
Scott Lahteine
eb85342fd9 Merge pull request #2989 from AnHardt/fix2661
Pre home display - Stepper release
2016-03-05 21:30:17 -08:00
Scott Lahteine
14f3ca1b2e Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
Apply bed leveling matrix when switching extruders
2016-03-05 21:23:25 -08:00
lrpirlet
0fb507a75d correct raise_z_for_servo 2016-03-05 20:19:53 -08:00
Blue-Marlin
b4e5e0f11d Add Watchdog reset in kill()
Add watchdog reset in the kill loop to simplify recovering.
2016-03-04 00:35:18 +01:00
Scott Lahteine
222d13d5ed Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
Code cleanup in gcode_T
2016-03-02 03:45:40 -08:00
Scott Lahteine
186629aee8 Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
2016-03-02 03:14:27 -08:00
jbrazio
67e15aac3d As pointed out by @Blue-Marlin the previous code would raise the Z axis
twice for a servo based probe.
2016-03-01 00:22:48 +00:00
jbrazio
17cc2a9663 Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
2016-02-29 15:48:26 +00:00
AnHardt
1c889cd303 Refresh previous_cmd_ms during run_z_probe()
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238)
2016-02-28 23:20:12 +01:00
AnHardt
4b02f33e69 Distribute config-changes to the other configurations 2016-02-28 23:20:04 +01:00
AnHardt
32ae9f9ab7 Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.

The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.

# Conflicts:
#	Marlin/Configuration_adv.h
2016-02-28 16:58:50 +01:00
AnHardt
b6e69e71ce Make stepper shutdown after inactivity dependent
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E

And make exemplaric Configuration.
Names can be discussed.

This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
2016-02-28 16:58:42 +01:00
AnHardt
051325ccd7 Introduce axis_homed
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:28 +01:00
Scott Lahteine
100271e6ac minor cleanup in gcode_T 2016-02-27 19:56:56 -08:00