Commit Graph

213 Commits

Author SHA1 Message Date
Robert F-C
788d62bcc4 Merge remote-tracking branch 'upstream/Marlin_v1' into Marlin_v1
Conflicts:
	Marlin/Marlin.pde
	Marlin/ultralcd.cpp
	Marlin/ultralcd_implementation_hitachi_HD44780.h
2013-04-29 21:13:46 +10:00
Robert F-C
9322c408c6 Updated for LiquidTWI2 library version 1.2.3
The new version of the library means that PANELOLU no longer needs to be
defined in LiquidTWI.h (the library file can be used as is) and the new
version of the library also enables the buzzer on the Panucatt VIKI
panel.
2013-03-24 18:19:58 +11:00
Dirk Eichel
26d8863111 Add library selection between GLCD and char. LCD 2013-03-19 20:03:47 +01:00
Robert F-C
6beb42cdf6 Attempt to address Bernhard's comments
Refactor configuration to try to make items clearer (what defines a
panel vs what is user changeable).
2013-03-01 01:17:07 +11:00
Robert F-C
839bef6d5d Fix Configuration.h file to not define LCDs be default.
Also fix compile time check in Marlin.pde
2013-02-28 02:32:20 +11:00
Robert F-C
1292d735ba Converge all I2C LCD branches (PANELOLU2, VIKI & PCF8575)
This includes refactoring the buttons code to remove a large amount of
non-pin dependent duplication from pins.h.
2013-02-28 02:04:51 +11:00
Bob Clough
b6209c86dd Added import of Wire Library to make I2C LCD support compilable 2013-02-25 15:15:23 +00:00
daid303
c5d4225804 Mistake there, not sure why I did that. My bad. 2012-12-05 20:23:13 +01:00
daid303
16078e47d4 Fixed #325 2012-12-04 16:27:21 +01:00
Erik vd Zalm
dbbf050005 More rambo fixes 2012-11-21 20:53:56 +01:00
Erik vd Zalm
f934d0ef5b Merge remote-tracking branch 'tonokip/Marlin_v1' into Marlin_v1
Conflicts:
	Marlin/Configuration.h
2012-11-21 20:36:30 +01:00
Erik vd Zalm
e48dfcc2b3 Tmp copy before merge 2012-11-21 20:29:31 +01:00
daid303
06b58a9c4f First cleanup. Moved all code to cpp files, so there are no dependencies on pde files. And no more odd requirement to cat files together. (Still need to fix the Makefile). Also cleaned up some defines and made defines upper case as by C coding conventions. 2012-11-06 12:06:41 +01:00
Mark Finn
bf7e453d02 Unwanted artifacts from unclean merge of bed-pid tree 2012-10-09 14:47:35 -05:00
ErikZalm
36a746d7d5 Merge pull request #244 from markfinn/pidbed
PID for heated bed
2012-10-08 11:15:16 -07:00
Mark Finn
d197f8504b clean up and changes from testing 2012-09-17 19:18:50 -05:00
Mark Finn
0a5ad3ab85 move comment to correct place 2012-09-17 08:42:35 -05:00
ZetaPhoenix
8ac5b29e02 Changes to M119 response for easier visual comparison
Changed to report on individual lines with "TRIGGERED" or "open" instead of "H" or "L" on one line as H&L could be confused with logic levels High and Low which may be wrong if using inverted logic.  Added strings to language.h.

Fixed typo "deu" in English language that was fixed in #134 but got added back in via 9f7f7354f5
2012-09-16 14:51:24 -07:00
ErikZalm
ba898faa7d Merge pull request #249 from gwelchc/patch-2
Slight modification for byte savings
2012-09-14 12:13:36 -07:00
G. W. C.
6ccbfeb80c Update Marlin/Marlin.pde
Added function 'setTargetedHotend' that turns into a function an operation repeated 3 times through the M-codes processing.

This modification saves a few bytes that can be used to add support for new commands.
2012-09-14 16:38:54 +03:00
andrey-vasilyev
1d389ad3a8 Fix M81 not working reliably on Gen7
Some discussion of the issue is here http://forums.reprap.org/read.php?181,118329,page=1
2012-09-13 19:23:48 +04:00
Mark Finn
9698f4ea64 bed pid
Conflicts:

	Marlin/Configuration.h
2012-09-12 21:18:59 -05:00
Erik vd Zalm
47319cf64e Fixed typo in SF arc fix code. 2012-09-03 21:28:31 +02:00
Erik vd Zalm
e358a2d7af Added fix for SF Arc Point fillet procedure 2012-09-02 01:12:49 +02:00
tonokip
1c1fddc7ac Added support for the Rambo reprap electronics board. Added Mcodes to set
motor current and microstepping pins.
2012-08-30 00:16:57 -07:00
ErikZalm
b86336c3f5 Merge pull request #221 from daid/Marlin_v1
Long filename support for LCD display
2012-08-22 06:30:35 -07:00
daid
b69e75c89a Added long filename support. 2012-08-22 14:49:57 +02:00
stohn
06c03fe2f0 new method for message for making KILLED message visible
The cli(); at the start of the kill() function also stops the internal
arduino timer which stops updating of millis() which prevents the
display of the "KILLED." message.
The new function updates the display directly without checking any
timers.
2012-08-22 12:44:41 +02:00
stohn
de0448343f added KILL_PIN support / cleaned up manage_inactivity function definition 2012-08-21 14:48:29 +02:00
Erik vd Zalm
9083966c22 Do not use feedrate multiiply on Z and E only moves. 2012-08-12 18:13:34 +02:00
Erik vd Zalm
f92dc91c3d Enable M503 also when eeprom is disabled 2012-08-11 15:49:40 +02:00
Ian Jackson
1dba212e18 HOMEAXIS: make into a function
Replace the large macro HOMEAXIS with a function.  This avoids the
compiler generating three copies of largely identical code.  The
saving is 724 bytes of program memory.

We make use of XYZ_CONSTS_FROM_CONFIG to provide convenient
array-shaped access to MAX_LENGTH, HOME_RETRACT_MM and HOME_DIR.

Signed-off-by: Ian Jackson <ijackson@chiark.greenend.org.uk>
2012-08-11 01:43:00 +01:00
Ian Jackson
7bb326d389 eeprom: provide smaller code for SERIAL_ECHOPAIR
SERIAL_ECHOPAIR implies, eventually, two calls to MYSERIAL.print.  One
of these has FORCE_INLINE for a per-character loop, and both involve
constructing a method call rather than a simple function call.

Produce better and smaller code by providing three specialised
functions serial_echopair.  This saves 672 bytes of program memory
(with EEPROM_SETTINGS and SDSUPPORT enabled).

Signed-off-by: Ian Jackson <ijackson@chiark.greenend.org.uk>
2012-08-11 01:42:59 +01:00
Ian Jackson
957e966d2d M206: always use homing ("homeing") offsets
Previously the parameters set in M206 would only be used if a G82
command was sent with specific axis home values.  This limits its
usefulness.

Really, we should have a way to adjust the XYZ homing of a machine in
the eeprom.  So as the first stage of this, make M206 affect every
home command.  The values set using M206 are now added to the
configuration variables [XYZ]_HOME_POS.

This is achieved by replacing all uses of [XYZ]_HOME_POS in the code
by a new home_pos[] which includes the adjustment.  We also have to
adjust the uses of [XYZ]_{MIN,MAX}_POS similarly - see below.


To allow axis_is_at_home to be written as a function taking an axis
index rather than a macro taking an axis letter, we provide
constant arrays in program memory containing the values of
[XYZ]_{MIN,MAX,HOME}_POS from the compiled-in configuration.

This is done with some helper macros to deal with the declaration
(XYZ_CONSTS_FROM_CONFIG) and definition of the inline function which
does the program memory access.

We also introduce the overloaded function read_pgm_any, whose
instances are produced with DEFINE_PGM_READ_ANY, which allows the
access functions to automatically produce the correct type.

The type- and pointer-massaging code in the access function boils
down, when compiled, to a simple program memory access.


A question arises: if the M206 offset is set, should this adjustment
to the home position shift or change the possible range of movement
permitted by the software endstops ?

The documentation in Configuration.h describes these limits as:
    // Travel limits after homing
Since this is a file containing physical limits, and actual suggested
values for these configuration parameters appear to include a certain
amount of slop, I've taken the view that these should be regarded as
nominal physical distances from the limit switches, and that the
permissible travel should be unaffected by M206.

So for example with the (rather unrealistic)
  #define X_HOME_DIR -1
  #define X_MIN_POS -20
  #define X_HOME_POS 0
  #define X_MAX_POS 100
no matter the setting of M206 X, the machine would be permitted
to move from 20mm "beyond" the limit switch trigger point in
the negative X direction and 100mm away from the limit switch in
the positive X direction, for a total travel of 120mm.

With M206 X-10 that would be considered to correspond to X coordinates
-30 to +90.  With M206 X+10 that would be considered to correspond to
X coordinates -10 to +110.


fixes #200 (in ErikZalm/Marlin).

Signed-off-by: Ian Jackson <ijackson@chiark.greenend.org.uk>
2012-08-11 01:35:03 +01:00
Ian Jackson
faccb35850 software_endstops: use *_MIN_POS and *_MAX_POS for arcs
If [XYZ]_HOME_POS and [XYZ]_MIN_POS aren't 0, these corrections are
wrong.  Use the same logic as in Marlin.pde:prepare_move: ie, clamp to
[XYZ]_{MIN,MAX}_POS.

While we're here, put this cut-and-paste code in a function
clamp_to_software_endstops.

Signed-off-by: Ian Jackson <ijackson@chiark.greenend.org.uk>
2012-08-10 19:36:30 +01:00
Ian Jackson
a873541ef6 Marlin.pde: include comment for emacs mode
Emacs by default doesn't recognise a ".pde" file as C++ source code.
Add the annotation to the top of the file to make it work.

Signed-off-by: Ian Jackson <ijackson@chiark.greenend.org.uk>
2012-08-10 19:36:29 +01:00
Chris Palmer
538189cc19 Fixed soft limits when the origin is in the middle.
HOME_POS is now always where the endstop is and can be outside the limits.
The limits are now defined by MIN_POS and MAX_POS rather than HOME_POS and MAX_LENGTH.
The Z is axis now homed first if direction is away from the bed.

Saguinololu limit pins change from MIN to MAX according to the homing direction.
2012-07-14 22:24:26 +02:00
Bernhard
d3002ef741 corrected retract 2012-06-03 16:56:40 +02:00
Bernhard
bf077125b9 added firmware retract. disabled by default 2012-06-02 20:32:28 +02:00
Bernhard Kubicek
c7ce99d495 Merge pull request #172 from daid/Marlin_v1
Add M401 - Wait for user to press button on LCD (with optional timeout) minor fix in M115.
2012-06-02 03:44:03 -07:00
ErikZalm
9e1021efbe Fixed SL bug. 2012-05-28 22:32:53 +03:00
Daid
4d7fe7115f Changed M401 to M0/M1 as suggested, so they match normal CNC stop commands. 2012-05-20 14:37:30 +02:00
Daid
16413bb8f2 Last M401 update, refresh the LCD during an M401 wait. 2012-05-19 18:53:56 +02:00
Daid
b3941fce5c Update after testing 2012-05-19 18:48:43 +02:00
Daid
516ec90242 Add M401 - Wait for user on LCD button press 2012-05-19 17:54:07 +02:00
MaikStohn
032df0b2c6 Moved LCD initialization out of constructor
Since the class "MainMenu" was used within a static variable the
initialization of the object (constructor call) was done before Arduino
library startup. It always caused a crash when using AVRStudio with
JTAG debugger (caused from calling the LCD initialization / the lot of
I/O work / the stack used during this calls). By moving the LCD_INIT
out of the constructor and using an explicit call inside of Arduino
setup() implementation immediately fixed all problems and the JTAG
debugger runs fine.
2012-05-03 14:28:17 +02:00
MaikStohn
060b38de5c delete obsolete and wrong code
"i" runs from 0 to 4 but "add_homeing" array size is 3 only. On the
other hand the calculated value gets overwritten by either one of the
if choice.
2012-05-03 14:15:46 +02:00
MaikStohn
789ba02d43 fixed typo in comment 2012-05-03 14:13:53 +02:00
Erik van der Zalm
1874cb71a6 Added option to increase the FAN PWM frequency. 2012-05-02 19:26:14 +02:00
Erik van der Zalm
e3821bd86f Merge branch 'Marlin_v1' of github.com:ErikZalm/Marlin into Marlin_v1 2012-04-30 13:36:27 +02:00