Commit Graph

21 Commits

Author SHA1 Message Date
InsanityAutomation
f6ec00d776 Update thermistor and working config 2019-06-04 20:25:00 -04:00
Scott Lahteine
605ec0a478 Fix thermistor table warning 2019-05-26 01:30:20 -05:00
Scott Lahteine
ad4ffa1d2f
Use C++ language supported 'nullptr' (#13944) 2019-05-09 11:45:55 -05:00
doggyfan
23a8707ef1 Configurable Thermistor (#13888) 2019-05-06 18:51:06 -05:00
3dlabsio
645ca7af7a M141 Heated Chamber, Temperature rework (#12201) 2019-03-07 02:09:39 -06:00
Scott Lahteine
44571775bd Further support for 6 extruders 2019-03-07 01:00:56 -06:00
InsanityAutomation
e2e2a55d9b Add thermistor type 67 SliceEng (#13275) 2019-02-28 19:44:17 -06:00
Scott Lahteine
0feeef2604 Update copyright in headers 2019-02-12 15:30:11 -06:00
InsanityAutomation
367a9f65aa Add Formbot 350c Thermistor (#12661) 2018-12-20 17:04:17 -06:00
Scott Lahteine
f5eab912ed
Apply #pragma once, misc cleanup (#12322)
* Apply #pragma once in headers
* Adjust some thermistors formatting
* Misc cleanup and formatting
2018-11-04 02:25:55 -06:00
Lee Olivares
094e6d81a5 Add Einstart-S support (#11219)
Indeed the HAL does not need to be mucked around with to expose ATmega2560 pins not available as numbers on the MEGA board, I'll need to update the wiki with that tidbit and a reference to the pin-mapping comment in `fastio_1280.h`.
2018-07-26 05:52:22 -05:00
Scott Lahteine
6b521b6df2 Loosen thermistor table size limit
Co-Authored-By: Aaron Griffith <aargri@gmail.com>
2018-07-11 21:08:07 -05:00
Scott Lahteine
568cfe7caa Add thermistor 501 (100K Zonestar) 2018-07-03 17:52:06 -05:00
Scott Lahteine
853a9056ac Long thermistor tables need special consideration 2018-05-28 06:28:34 -05:00
Scott Lahteine
325bbbc8c2
[2.0.x] Enable AD595 and AD8495 in concert (#10693)
* Allow both AD595 and AD8495 in concert
* General temperature code tweaks
2018-05-11 01:01:51 -05:00
Lenbok
0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
ABH10
ac6bf7226a Update of comments in thermistor files. No functional changes. (#8986) 2018-02-04 06:06:21 -06:00
Scott Lahteine
7d6c009104 Add thermistor 15 tuned for JGAurora A5 2018-01-22 01:27:11 -06:00
Scott Lahteine
0918dae66e Add OV() macro for use in thermistor tables 2017-11-15 03:15:18 -06:00
Scott Lahteine
3d8a0ab4b2 Module updates 2017-09-21 16:26:42 -05:00
Scott Lahteine