Scott Lahteine
f0b96f5cae
Merge pull request #3276 from thinkyhead/rc_sdprint_and_lcd_sleuth
...
Refinements, fixes, reduced stack usage in CardReader
2016-03-29 18:30:18 -07:00
Scott Lahteine
12c0bf9521
Merge pull request #3277 from jbrazio/bugfix/m190-temp-never-reached
...
M190 bed temp is never reached
2016-03-29 18:28:51 -07:00
João Brázio
c6577aea60
M190 bed temp was never reached
2016-03-30 01:03:20 +01:00
Scott Lahteine
27d70599d4
Change openFile default to "not-push" instead of "do-replace"
2016-03-29 03:16:35 -07:00
Scott Lahteine
3252df7998
Minor cleanup to filament sensor code
2016-03-28 20:04:34 -07:00
Scott Lahteine
0b8ef5eba6
Split get_command into units, rename to get_available_commands
2016-03-28 06:00:04 -07:00
Scott Lahteine
545f7997ea
Continue on empty lines instead of returning
2016-03-28 05:37:36 -07:00
Scott Lahteine
3dcf6d42ff
Don't store escaped serial characters if comment_mode
2016-03-28 05:37:36 -07:00
Scott Lahteine
5f8e52aefb
Minor cleanup to command dispatcher
2016-03-28 05:37:36 -07:00
Scott Lahteine
f1ed310322
Add NUMERIC compare macros to simplify code
2016-03-28 03:52:49 -07:00
jbrazio
443e6d26fe
Formatted multi-line comments
2016-03-27 04:36:36 +01:00
Scott Lahteine
e4039a9b5b
Merge pull request #3250 from esenapaj/patch-1
...
Fix typo
2016-03-26 00:41:31 -07:00
Scott Lahteine
cd4c3e90bc
Send a busy signal every 10 seconds instead of every 2
2016-03-25 22:15:40 -07:00
Scott Lahteine
26168676e7
Merge pull request #3246 from thinkyhead/rc_fix_numeric_filenames
...
Fix: current_command_args skips digits at the front
2016-03-25 16:38:36 -07:00
esenapaj
f54315c728
Fix typo
...
These are salvaged from closed-PR #3216 .
2016-03-26 08:37:17 +09:00
Scott Lahteine
f423716c6a
Fix: current_command_args skips digits at the front
...
Closes #3245
2016-03-25 16:12:41 -07:00
Scott Lahteine
18de9f55ac
Merge pull request #3242 from thinkyhead/rc_epatel_mesh_fixes
...
Updated Mesh Bed Leveling
2016-03-25 06:48:12 -07:00
Scott Lahteine
3a1e6b1752
Merge pull request #3243 from AnHardt/homed
...
axis_known_position -> axis_homed
2016-03-25 06:36:46 -07:00
AnHardt
94962ee678
axis_known_position -> axis_homed
...
In all these cases we want the axis to be homed. If we could have lost
some steps is secondary.
Reenables homing seperate axis with DISABLE_X / DISABLE_Y true.
2016-03-25 14:05:20 +01:00
Edward Patel
14afe1a017
Move to Z=0 for G28 when using Manual Bed Leveling
...
copy of 406992f9dd
2016-03-25 04:58:44 -07:00
Edward Patel
c606ed447a
Add "G29 S4" to fine tune Z level for Mesh Bed Leveling.
...
Also add mbl.z_offset to the EEPROM, bumping the version to V23.
2016-03-25 04:58:43 -07:00
Scott Lahteine
5d8036e554
Code cleanup around MOTOR_CURRENT_PWM options
2016-03-25 04:23:46 -07:00
Scott Lahteine
0da744b7b0
Further cleanup of comments, partial Doxygen-style
...
Following up on #3231
2016-03-25 00:45:56 -07:00
Scott Lahteine
4823791eb0
Merge pull request #3228 from esenapaj/patch-1
...
Fix spelling
2016-03-25 00:40:51 -07:00
jbrazio
5e5d250832
Added gplv3 header to all Marlin files
2016-03-24 18:01:20 +00:00
esenapaj
89a845659a
Fix spelling
...
PROBABLE ->PROBEABLE
This is follow-up to #3069 ?
2016-03-25 02:13:37 +09:00
Scott Lahteine
af32a7d5d6
M120/M121 also set endstops non-homing state
2016-03-24 03:24:23 -07:00
Scott Lahteine
04fa9d4f47
Make Autotune options into Menu Edit Items
2016-03-24 02:00:08 -07:00
WPBack
e3f583a3be
Fixes for PID AutoTune from menu
...
Fixes for #3189
Setting a temp is still missing
2016-03-24 01:47:30 -07:00
WPBack
3b3e8a02b5
Initial implementation of PID Autotune Menu Items
...
Adds the parameter U to M303. If U1 is included , it will use the
PID-values from the auto-tune.
2016-03-24 01:46:37 -07:00
Scott Lahteine
c5857f96c8
Merge pull request #3182 from thinkyhead/rcbugfix_printrboard_revf
...
Add support for Printrboard RevF
2016-03-24 00:12:06 -07:00
Scott Lahteine
f774420488
Merge pull request #3196 from thinkyhead/rc_controllerfan_bug
...
Make DISABLE_INACTIVE_X, etc., true if missing
2016-03-24 00:11:46 -07:00
AnHardt
1c6a16d5bb
Send position updates to RH
...
Send position updates to RH where RH can not know the end position.
For example after G28 RepetierHost assumes to be at the homing-point,
but with a servo probe we are much higher. Now the RH-software-endstops
will prevent us from going down (if activated). With this patch the
internal position of RH is updated with `current_position[]`.
2016-03-23 13:30:50 +01:00
AnHardt
6486e8b74a
Call buzz() directly from M428
2016-03-22 15:05:04 +01:00
Scott Lahteine
b1a3a95ad4
Tweak controllerFan to save a cycle or two
2016-03-20 22:11:09 -07:00
Scott Lahteine
10caee2b7c
Merge pull request #3187 from AnHardt/target_extruder_number
...
Fix extrudernum in MSG_INVALID_EXTRUDER
2016-03-20 17:15:22 -07:00
Scott Lahteine
1cc316f1fd
Merge pull request #3082 from thinkyhead/updated_2820
...
This is quite comprehensive. If probes are disabled in any case when they shouldn't be, I'm sure we will hear about it soon.
2016-03-20 17:10:38 -07:00
Scott Lahteine
7bf5d117e7
Merge pull request #3069 from thinkyhead/rc_delta_compat_m48
...
Delta-compatible extensions to M48
2016-03-20 17:09:18 -07:00
Scott Lahteine
06332f20be
Merge pull request #3113 from jbrazio/bugfix/3061-stop-print-time-counter
...
Stop print timer with M105/M109
2016-03-20 17:05:07 -07:00
AnHardt
338b69c24b
Fix extrudernum in MSG_INVALID_EXTRUDER
...
SERIAL_ECHO is not very good in printing uint8_t - so cast. to int.
2016-03-20 11:39:06 +01:00
AnHardt
b39b54031b
Fix KEEPALIVE_STATE
...
Add return to NOT_BUSY for M105
Replace WAIT_FOR_USER with PAUSED_FOR_USER
Add Travis test for FILAMENTCHANGEENABLE
2016-03-20 10:41:56 +01:00
Scott Lahteine
41145e6e81
Patch drain_queued_commands_P
...
Fix a SNAFU that should have been caught in #3012
2016-03-19 20:10:41 -07:00
Scott Lahteine
59483221d5
Move stepper DAC to a separate file
2016-03-19 19:24:26 -07:00
Scott Lahteine
5d0570cea0
Make digitalPotWrite depend on HAS_DIGIPOTSS
2016-03-19 19:24:26 -07:00
Scott Lahteine
f96bc03081
Add M907-M910 g-codes support for Printrbot Rev. F
2016-03-19 19:24:26 -07:00
Scott Lahteine
cf7c444aff
Apply unknown_position_error elsewhere
2016-03-19 05:13:40 -07:00
Scott Lahteine
eda5190581
Check for known position in M48
2016-03-19 05:13:40 -07:00
Scott Lahteine
68085ca855
Updated M48 friendly for DELTA
...
Partial implementation with reference to MarlinFirmware/Marlin#3011
2016-03-19 05:13:40 -07:00
Scott Lahteine
38b0082bf2
Additional tweaks to M42 exit conditions
2016-03-19 03:10:18 -07:00
Scott Lahteine
4bbea5124d
Support for multiple PWM fans
2016-03-19 03:10:18 -07:00
Scott Lahteine
637cc03686
Fix M109 so it won't wait for cooling
...
Addressing issue #2767
2016-03-19 03:00:58 -07:00
AnHardt
3f45a1acf9
Check probes only when deployed
...
Aim: Test probes in update_endstops only when activated
Changes:
Configurations
Add define for FIX_MOUNTED_PROBE to handle the situation where formerly ENDSTOPS_ONLY_FOR_HOMING had to be set, or lowering the nozzle below Z_PROBE_OFFSET_FROM_EXTRUDER could give an "endstop hit" message.
Add define for Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to indicate a common situation, that we have a probe but it is connected to an endstop pin
Add some comments
Shift some entries to have related things together.
Conditionals.h
We have a probe (HAS_Z_MIN_PROBE) if one of the pins is defined AND one of the probes is defined.
SanityCheck.h
Add some tests if the probe is connected and if we have defined a probe.
stepper.cpp
Changes to test the probe only when it is deployed (z_probe_is_active).
Test update_endstops() when the probe is deployed.
MarlinMain.cpp
a. set and reset z_probe_is_active in deploy_z_probe(), stow_z_probe() and dock_sled()
b. set and reset z_probe_is_active in the case a z-servo is moved to a defined position. The only remaining unhandled servo move is in M280 where we do not end in a defined position. If you want to handle a probe use M401/402
c. skip deploying/stowing when already deployed/stowed in the dedicated deploy/stow functions.
d. Handle the new FIX_MOUNTED_PROBE in parallel to a servo driven probe/endstop.
To do: In another PR. handle all probes in deploy/stow_z_probe.
Sort out SERVO_LEVELING vs. HAS_SERVO_ENDSTOPS.
2016-03-19 02:00:08 -07:00
Scott Lahteine
4634feaeab
Merge pull request #3012 from thinkyhead/fix_command_injection
...
Use a serial line buffer to prevent queue corruption
2016-03-19 01:43:54 -07:00
Scott Lahteine
963a92ceda
Patch idle forevermore
2016-03-18 22:38:35 -07:00
Scott Lahteine
7ec7bb31c4
Send a Busy signal to hosts during long processes, wait for input, etc
...
If Marlin is blocking the serial input or command queue for any length
of time (for example more than 2 seconds), it needs to send a message
to serial out to inform the host that it is busy. Marlin should only
send these messages out when busy, and preferably not when trying to
print formatted output.
2016-03-18 22:38:35 -07:00
Scott Lahteine
80277cc9c8
drain_queued_commands_P now returns true if there are more
2016-03-18 17:56:48 -07:00
Scott Lahteine
8fe7420310
Use a separate serial line buffer
2016-03-18 16:46:20 -07:00
Scott Lahteine
7d25c107a8
Merge pull request #3149 from esenapaj/patch-1
...
suppress warnings
2016-03-18 15:40:14 -07:00
Scott Lahteine
e8fa843c2d
Merge pull request #3164 from epatel/epatel/RCBugFix
...
Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z
2016-03-16 02:40:54 -07:00
Scott Lahteine
d7c6fd5c2f
Merge pull request #3146 from thinkyhead/rc_enabled_true_false
...
Support "true" and "false" in the ENABLED macro
2016-03-15 17:35:55 -07:00
Edward Patel
cb0dbfa3b5
Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z
2016-03-16 01:26:00 +01:00
Scott Lahteine
6e1bc03d3b
Additional wrapping for #3140
2016-03-15 01:18:58 -07:00
Scott Lahteine
1c384930f3
Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
...
Wrap macros to prevent bad expansions
2016-03-15 00:25:34 -07:00
esenapaj
a4314c4907
Use local variable in recalc_delta_settings()
...
diagonal_rod hadn't been used anywhere.
2016-03-15 06:47:27 +09:00
esenapaj
8de7a6f9b1
suppress warnings
2016-03-15 06:34:02 +09:00
Scott Lahteine
4b648793f2
Use ENABLED with DISABLE_[INACTIVE_][XYZ]
2016-03-13 22:15:45 -07:00
Scott Lahteine
3f5fbbd398
Merge pull request #3124 from jbrazio/bugfix/update-g29-auto-level-bed-topography
...
Update the bed topography output done by G29
2016-03-13 03:51:43 -07:00
Scott Lahteine
f9ded2a7c4
Wrap macros to prevent bad expansions
2016-03-12 22:38:55 -08:00
jbrazio
a645860431
All print timer related activity now uses print_job_start(), print_job_timer() or print_job_stop()
2016-03-12 07:16:39 +00:00
jbrazio
1981e53d68
M109 R option if misused could cause a wait-forever situation
2016-03-12 06:24:24 +00:00
João Brázio
4d4a842cfb
Update the bed topography output done by G29
2016-03-10 13:24:17 +00:00
João Brázio
793cd0ae3b
Clean up the code a bit
2016-03-10 11:52:43 +00:00
jbrazio
986b508ff7
Print timer now stops when it sees the last extruder temperature being shutdown
2016-03-08 18:11:02 +00:00
AnHardt
fd5414c6ea
Z_RAISE_BEFORE_HOMING -> MIN_Z_HEIGHT_FOR_HOMING
...
rebased
corrected spelling
changed to #elif for error
Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
2016-03-08 17:50:23 +01:00
Scott Lahteine
b7928a000a
Merge pull request #3108 from AnHardt/M110+
...
M110 and M29 rework
2016-03-08 03:54:07 -08:00
Scott Lahteine
5cba0b4187
Merge pull request #3111 from thinkyhead/rc_drop_old_condition
...
Drop obsolete test for leading "N"
2016-03-08 03:07:25 -08:00
Scott Lahteine
302d1bfbc4
Drop obsolete test for leading "N"
2016-03-08 02:25:11 -08:00
AnHardt
37b857e8ec
M110 ang M29 rework
...
Add 'ok' output for G29 actually closing the file.
Handle M110 when received without linenumber/checksumm.
2016-03-07 22:27:01 +01:00
Scott Lahteine
fac85f6fa1
Merge pull request #3102 from jbrazio/bugfix-g28-multiple-z-movements
...
Bugfix: G28 was lifting Z-axis multiple times
2016-03-07 03:52:00 -08:00
jbrazio
642e3699ce
Z-axis was being lift multiple times if Z_SAFE_HOMING was enabled and Z_RAISE_BEFORE_HOMING was greater than zero
2016-03-07 03:49:11 +00:00
Scott Lahteine
501f63802a
Merge pull request #3077 from Blue-Marlin/watchdogreset-in-kill
...
Add Watchdog timer reset in kill()
2016-03-06 16:21:39 -08:00
Scott Lahteine
ef68c1910c
Check that the temperature is close to target
2016-03-06 05:51:56 -08:00
Scott Lahteine
ea9fd1200b
Fix M109 so it won't wait for cooling
...
Addressing issue #2767
2016-03-06 05:51:56 -08:00
Scott Lahteine
ff13070b59
Use _BV macros, patch up others
2016-03-06 05:51:55 -08:00
Scott Lahteine
209f5f21e0
Use macros where possible
...
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
2016-03-06 05:51:55 -08:00
Scott Lahteine
6e64895c30
Merge pull request #3001 from AlwaysTinkering/RCBugFix
...
Rc bug fix - Fix for issue #2931
2016-03-06 00:20:29 -08:00
Scott Lahteine
34b8b9f0f5
Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
...
Add CORE support to st_get_position_mm (and elsewhere)
2016-03-06 00:17:03 -08:00
Scott Lahteine
3a3d358df9
Fix Printrboard with LCD (redo)
...
Based on #2860 - rebased for RCBugFix
2016-03-05 22:13:00 -08:00
Scott Lahteine
eb85342fd9
Merge pull request #2989 from AnHardt/fix2661
...
Pre home display - Stepper release
2016-03-05 21:30:17 -08:00
Scott Lahteine
14f3ca1b2e
Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
...
Apply bed leveling matrix when switching extruders
2016-03-05 21:23:25 -08:00
lrpirlet
0fb507a75d
correct raise_z_for_servo
2016-03-05 20:19:53 -08:00
Blue-Marlin
b4e5e0f11d
Add Watchdog reset in kill()
...
Add watchdog reset in the kill loop to simplify recovering.
2016-03-04 00:35:18 +01:00
Scott Lahteine
222d13d5ed
Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
...
Code cleanup in gcode_T
2016-03-02 03:45:40 -08:00
Scott Lahteine
186629aee8
Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
...
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
2016-03-02 03:14:27 -08:00
jbrazio
67e15aac3d
As pointed out by @Blue-Marlin the previous code would raise the Z axis
...
twice for a servo based probe.
2016-03-01 00:22:48 +00:00
jbrazio
17cc2a9663
Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
...
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
2016-02-29 15:48:26 +00:00
AnHardt
1c889cd303
Refresh previous_cmd_ms during run_z_probe()
...
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238 )
2016-02-28 23:20:12 +01:00
AnHardt
4b02f33e69
Distribute config-changes to the other configurations
2016-02-28 23:20:04 +01:00
AnHardt
32ae9f9ab7
Fix stepper shutdown during waiting for temperatures
...
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.
The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.
# Conflicts:
# Marlin/Configuration_adv.h
2016-02-28 16:58:50 +01:00
AnHardt
b6e69e71ce
Make stepper shutdown after inactivity dependent
...
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E
And make exemplaric Configuration.
Names can be discussed.
This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
2016-02-28 16:58:42 +01:00
AnHardt
051325ccd7
Introduce axis_homed
...
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".
# Conflicts:
# Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:28 +01:00
Scott Lahteine
100271e6ac
minor cleanup in gcode_T
2016-02-27 19:56:56 -08:00
Scott Lahteine
6a4f06d35d
Fix GCode handling of spaces between command letter and first digit
2016-02-26 18:42:59 -08:00
CONSULitAS
ea8409ad5d
Fix: current_command_args contains command
...
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.
see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on
Greetings and welcome back
Jochen
2016-02-24 09:35:04 +01:00
Scott Lahteine
e1beaf61eb
Merge pull request #2985 from AnHardt/adv-ok
...
Repair N in ADVANCED_OK
2016-02-18 17:06:26 -08:00
Scott Lahteine
0c9db67273
Merge pull request #2983 from AnHardt/ok-echo
...
Replace the "ok" in M280, M301, M304, M851 with output not including …
2016-02-17 19:09:41 -08:00
Scott Lahteine
8eaba020fb
Merge pull request #2973 from thinkyhead/fix_splash_url
...
Remove references to marlinfirmware.org
2016-02-17 17:05:06 -08:00
Scott Lahteine
be691b51f1
Remove references to marlinfirmware.org
...
The domain is gone and doesn’t redirect, so for now show no URL on the boot screen.
2016-02-17 14:41:46 -08:00
Scott Lahteine
83ffc9eb4f
Show raw steps in M114
...
This is a proposed change. This section of M114 output is a debug
extension according to RepRap wiki.
2016-02-15 15:59:24 -08:00
Scott Lahteine
373e8a1ad4
Fixes for COREXY and COREXZ coordinates
2016-02-15 15:59:24 -08:00
unknown
31656e68bc
Fix for homing X and Y before raising Z when Z_SAFE_HOMING is set.
2016-02-15 15:53:40 -06:00
unknown
8ea55323d8
Fix for not raising Z before homing X and Y
2016-02-15 14:52:04 -06:00
Scott Lahteine
711e5db19a
Tweak comment in process_next_command
2016-02-09 18:16:35 -08:00
Scott Lahteine
400e9329be
Allow spaces after a code letter
2016-02-09 18:03:13 -08:00
Scott Lahteine
cdcb80f3c5
Allow no-space after initial command
...
Addresses issue #2715
2016-02-09 18:00:35 -08:00
AnHardt
6f473f7fc6
Repair N in ADVANCED_OK
...
Send the correct line number.
If no N was in the command - non't send an N.
2016-02-09 19:23:26 +01:00
AnHardt
efbd705eda
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
...
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
to avoid senting two "ok"s for a single g-code.
Doing the same for M105 would break the input filters of the hosts.
For M105 the other "ok" is omitted.
2016-02-09 13:36:03 +01:00
Scott Lahteine
8e66028d25
Apply the ABL rotation matrix to the extruder offset.
2016-02-08 14:22:18 -08:00
Richard Wackerbarth
f6950acb8e
Residual unused variable — Backport
2015-12-10 19:48:08 -06:00
AnHardt
57da1b8497
Host parseble output for M109, M190 and M303
...
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
2015-12-07 15:37:53 -06:00
AnHardt
fcceb98191
Unglobalize no_wait_for_cooling
2015-12-07 15:34:26 -06:00
Richard Wackerbarth
e293ea57f0
Unbalanced brackets in setPwmFrequency
...
This is a back port of the correct in issue #248
2015-11-30 05:44:32 -06:00
Scott Lahteine
17c23bbaf3
Shorten gcode_M221 yet function the same
2015-11-12 00:03:22 -06:00
Scott Lahteine
c0e791dbe9
Only look for "N" line number as first parameter
2015-11-12 00:03:22 -06:00
Scott Lahteine
b4af4441c5
Clean up watchdog impl.
2015-11-12 00:03:22 -06:00
Scott Lahteine
9bdab4f3a8
Clean up "else" and other spacing
2015-11-12 00:03:21 -06:00
Richard Wackerbarth
25d636c9e0
Compiler issues (PR#2696)
2015-11-11 23:52:11 -06:00
Scott Lahteine
ba6a243197
DEBUG message has no parameter (PR#2671)
2015-10-03 22:03:03 -05:00
Scott Lahteine
0c7f7ebcfb
Styling adjustments (PR#2668 & PR#2670)
...
Keep "astyled" reformatting
2015-10-03 22:02:45 -05:00
fmalpartida
0f149ea0c6
LCD home button causes repeated homing (PR#175)
...
Fix: increased debounce delay.
2015-09-14 06:31:49 -05:00
Scott Lahteine
b825567e0f
Drop www. from marlinfirmware.org (PR#175)
2015-09-14 06:28:53 -05:00
Scott Lahteine
bc50db9cf6
Implement PID_ADD_EXTRUSION_RATE
2015-09-12 07:53:20 -05:00
Scott Lahteine
fabf3ae4a0
Add final Z raise after Delta probe
2015-09-12 07:23:24 -05:00
Shane Francis
4c8330c15c
Trim Adjustments for Delta Configurations
2015-09-03 01:05:33 -05:00
Scott Lahteine
962120d1d2
Fix spacing in some conditional blocks
2015-08-27 20:59:09 -05:00
Richard Wackerbarth
20b4772155
Create DEBUG_LEVELING_FEATURE
2015-08-27 20:52:08 -05:00
Scott Lahteine
194f98ff95
Debug messages for homing and leveling
2015-08-27 20:52:08 -05:00
Richard Wackerbarth
6292d9e815
Rename ENABLE_AUTO_BED_LEVELING
...
With the introduction of the #if ENABLED(…)
reads better than
2015-08-27 20:52:08 -05:00
Christian Lefrançois
9897a9147c
Update ABL comments (PR#95)
...
* Updates the auto bed leveling comments ONLY.
* Renames "Z probe" word usage in //comments and #errors properly.
2015-08-26 05:51:38 -05:00
Scott Lahteine
23d742bf06
Don't free the stack array plane_equation_coefficients (PR#83)
2015-08-16 06:53:24 -05:00
Scott Lahteine
e3b1e08777
Patch G30 to use raise_z_for_servo (PR#73)
2015-08-15 21:47:04 -05:00
Scott Lahteine
a1eb90d5c0
Save another 30 bytes in gcode_SET_Z_PROBE_OFFSET
2015-08-12 21:26:32 -05:00
Scott Lahteine
91122277f4
Reduce gcode_SET_Z_PROBE_OFFSET by 88 bytes
2015-08-12 21:26:25 -05:00
AnHardt
5707a2c3d5
indexindexIntoAB is only vald for !DELTA
2015-08-11 17:32:11 -05:00
AnHardt
d8860f9ad9
Alway end at the same point
...
Always end at [RIGHT_PROBE_BED_POSITION, BACK_PROBE_BED_POSITION]
Regardles the evennes of auto_bed_leveling_grid_points.
2015-08-11 17:32:11 -05:00
AnHardt
4ca8f4a9a7
Always zigzag
...
Use the shortest way between probing-points.
2015-08-11 17:32:11 -05:00
AnHardt
3d23424121
Add array indexIntoAB[xx][yy]
...
and use it.
2015-08-11 17:32:11 -05:00
AnHardt
e2d69f66b2
Make Z_PROBE a Z_MIN_PROBE (PR#65)
...
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.
Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX check for the probe in update_endstops().
Using an delta related idea of @clefranc from #61 ,
extended to the general change for all setups.
Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
2015-08-11 14:41:36 -05:00
Richard Wackerbarth
9d8cc24abf
Continue from the line following the M999 (PR#60)
...
If the printer is going to accept the M999,
then it should continue from that line number.
2015-08-08 08:08:02 -05:00
Scott Lahteine
46453905d6
Apply remaining ENABLED/DISABLED conditionals
2015-08-03 16:04:48 -05:00