Commit Graph

1443 Commits

Author SHA1 Message Date
João Brázio
e71a631f8f do_blocking_move_*() no longer depend on HAS_BED_PROBE 2016-07-15 01:54:14 +01:00
Scott Lahteine
8bf6861af8 Merge pull request #4054 from jbrazio/feature/g12-clean-tool
Implements clean nozzle feature (Lulzbot's REWIPE)
2016-07-14 14:38:38 -07:00
Scott Lahteine
1618870c84 card.printingHasFinished does print_job_timer.stop 2016-07-14 11:39:58 -07:00
Scott Lahteine
34da77dad3 Simply run M31 at the end of an SD print 2016-07-14 11:39:58 -07:00
Scott Lahteine
a8d71f0ac6 Support longer print times in M31 2016-07-14 11:39:58 -07:00
Scott Lahteine
e481b79af1 Allow stopwatch and printcounter to go over 18 hours 2016-07-14 11:39:57 -07:00
João Brázio
4937f9ada4 Minor G12 tweaks and point_t struct extension 2016-07-14 00:07:36 +01:00
João Brázio
021544f572 Improves G12 zig-zag pattern 2016-07-13 21:14:56 +01:00
João Brázio
b05a75655a Implements a nozzle cleaning pattern generator (G12) 2016-07-13 21:14:19 +01:00
Scott Lahteine
4f77adddbe Merge pull request #4286 from thinkyhead/rc_debug_clean
Prefix and suffix in debug output
2016-07-12 20:49:15 -07:00
Scott Lahteine
e5c7af5ddc Merge pull request #4222 from thinkyhead/rc_allow_cold_extrude
M302: Add "P" parameter, status output
2016-07-12 20:40:14 -07:00
Scott Lahteine
2224032568 Merge pull request #4285 from thinkyhead/rc_manual_move_fast_fine
No delay for the smallest LCD moves
2016-07-12 20:16:38 -07:00
Scott Lahteine
d4c68279c8 Add "P" parameter to M302 2016-07-12 20:04:15 -07:00
Scott Lahteine
a8b6b6a128 Merge pull request #4252 from thinkyhead/rc_rename_hpb
Replace PLA/ABS preheating with generic
2016-07-12 20:00:33 -07:00
Scott Lahteine
1e14df876d Use varname as prefix in DEBUG_POS, string as suffix 2016-07-12 19:58:09 -07:00
Scott Lahteine
9e8b3e5ee6 Homing direction is irrelevant in probe raise! 2016-07-12 18:09:02 -07:00
Scott Lahteine
4865447830 Merge pull request #4276 from esenapaj/Suppress-warnings
Suppress warnings
2016-07-11 19:08:59 -07:00
esenapaj
58177a1602 Suppress warnings 2016-07-12 08:22:24 +09:00
AnHardt
7bcab26f2a Don't deploy/stow the probe if z-min-endstop is used for homing
Don't deploy/stow the probe if z-min-endstop is used for homing.
Don't apply `zprobe_zoffset` if probe was not used.
2016-07-11 22:01:44 +02:00
AnHardt
e92e58df1f Adjust wait_for_cooling slope
Adjust wait_for_cooling slope
and drop mintemp for cooling.

See
https://github.com/MarlinFirmware/Marlin/pull/4169#issuecomment-231544532
2016-07-11 03:36:23 +02:00
Scott Lahteine
ee0983ab57 Further reduction when HOTENDS == 1 2016-07-10 16:54:30 -07:00
Scott Lahteine
f9e08b1fcd Merge pull request #4254 from AnHardt/killscreen
Add a kill-screen
2016-07-09 20:44:42 -07:00
AnHardt
faac2bcfdb Add a kill-screen 2016-07-10 04:50:45 +02:00
Scott Lahteine
3b3e52616c Merge pull request #4253 from thinkyhead/rc_clexpert_runout
Runout Sensor without SD Card, Print Timer support in M104
2016-07-09 19:10:36 -07:00
Scott Lahteine
4cd045791c Reduce code size by trusting the compiler 2016-07-09 18:17:44 -07:00
Scott Lahteine
a8538bd7ce General cleanup, code reduction in Marlin_main.cpp 2016-07-09 18:17:44 -07:00
Scott Lahteine
1026e5b071 Replace PLA/ABS preheating with generic 2016-07-09 18:06:51 -07:00
Petr Zahradník junior
315b4c2153 Runout sensor without SD Card 2016-07-09 17:57:53 -07:00
AnHardt
468f7f03a2 homeaxis() can leave early
when no known axis needs to be homed.

Most changes are only caused from altering the indentation.
```
if (axis == X_AXIS ? HOMEAXIS_DO(X) : axis == Y_AXIS ? HOMEAXIS_DO(Y) : axis == Z_AXIS ? HOMEAXIS_DO(Z) : 0) {
  ...
}

to

if (!(axis == X_AXIS ? HOMEAXIS_DO(X) : axis == Y_AXIS ? HOMEAXIS_DO(Y) : axis == Z_AXIS ? HOMEAXIS_DO(Z) : 0)) return;
...

```
2016-07-08 15:59:33 +02:00
AnHardt
eff7912243 Ensble/disable hardware endstops in G28 globally.
For moving away from the endstops we do not have to disable them.
They are not tested anyway.
2016-07-08 15:49:10 +02:00
AnHardt
f69434d81c Eliminate void setup_for_endstop_move() 2016-07-08 15:23:20 +02:00
AnHardt
0ea6247fc2 Use logic in Z_SAFE_HOMING
Use logic in Z_SAFE_HOMING

From
```
if (home_all_axis || homeZ) {
  if (home_all_axis) {
  ...
  home z
  }
  else if (homeZ) { // Don't need to Home Z twice
  home z
  }
}

```
to
```
if (home_all_axis || homeZ) {
  if (home_all_axis) {
  ...
  }
  home z
}
```
2016-07-08 15:08:50 +02:00
AnHardt
de3a169336 Always define MIN_Z_HEIGHT_FOR_HOMING even if 0
Always define MIN_Z_HEIGHT_FOR_HOMING even if 0
Always make a potential rise to `home_offset[Z_AXIS]` possible in G28.
Get rid of some very ugly constructs in MBL (ultralcd.cpp).
2016-07-08 15:08:32 +02:00
AnHardt
88ed232f53 Remove HAS_BED_PROBE case in first raise in G28
Differentiating made sense here when we could save a dozen lines of code,
but not for one line.
2016-07-08 14:59:44 +02:00
AnHardt
653eff3b31 Clean up quick_home_xy()
Since we do the actual homing now in the 'normal' routines `quick_home_xy()`
can be simplified to a relative simple diagonal move.
2016-07-08 14:59:27 +02:00
Scott Lahteine
98d0167a57 Merge pull request #4226 from thinkyhead/rc_emergency_command_parser
MarlinSerial emergency-command parser (with M108)
2016-07-07 16:53:55 -07:00
Scott Lahteine
2ee4e4f791 Make wait_for_heatup volatile 2016-07-07 16:37:23 -07:00
Scott Lahteine
834ad14c8d Add quickstop_stepper to update current position with stepper.quick_stop() 2016-07-07 16:37:22 -07:00
Scott Lahteine
ecffe92e20 Group EMERGENCY_PARSER commands 2016-07-07 16:37:22 -07:00
AnHardt
a129078927 Add an emergency-command parser to MarlinSerial (supporting M108)
Add an emergency-command parser to MarlinSerial's RX interrupt.

The parser tries to find and execute M108,M112,M410 before the commands disappear in the RX-buffer.

To avoid false positives for M117, comments and commands followed by filenames (M23, M28, M30, M32, M33) are filtered.

This enables Marlin to receive and react on the Emergency command at all times - regardless of whether the buffers are full or not. It remains to convince hosts to send the commands. To inform the hosts about the new feature a new entry in the M115-report was made. "`EMERGENCY_CODES:M112,M108,M410;`".

The parser is fast. It only ever needs two switch decisions and one assignment of the new state for every character.

One problem remains. If the host has sent an incomplete line before sending an emergency command the emergency command could be omitted when the parser is in `state_IGNORE`.
In that case the host should send "\ncommand\n"

Also introduces M108 to break the waiting for the heaters in M109, M190 and M303.

Rename `cancel_heatup` to `wait_for_heatup` to better see the purpose.
2016-07-07 16:37:22 -07:00
Scott Lahteine
9f42b1a075 Merge pull request #4235 from thinkyhead/rc_revert_quickhome_test
Fix quick homing, tweak MIN_Z_HEIGHT_FOR_HOMING
2016-07-07 13:37:14 -07:00
Scott Lahteine
ad968f2325 Merge pull request #4234 from thinkyhead/rc_better_position_logging
Move XYZ in print_xyz and DEBUG_POS to the front
2016-07-07 12:31:15 -07:00
Scott Lahteine
4036c73cdd Don't raise Z if only homing Z 2016-07-07 12:28:37 -07:00
Scott Lahteine
0b6f8f8244 Apply MIN_Z_HEIGHT_FOR_HOMING raise literally 2016-07-07 12:25:02 -07:00
Scott Lahteine
177ec20bf0 Revert quick-home changes 2016-07-07 12:17:34 -07:00
Scott Lahteine
9c5b462ef2 Move XYZ in print_xyz and DEBUG_POS to the front 2016-07-07 11:42:19 -07:00
Scott Lahteine
4e84c803a3 Merge pull request #4232 from thinkyhead/rc_no_axis_codes_needed
Don't use axis_codes if a literal will do
2016-07-06 20:05:16 -07:00
Scott Lahteine
e2f7cb0905 Don't use axis_codes if a literal will do 2016-07-06 18:37:21 -07:00
Scott Lahteine
6559f7359f Fix comment on Z raise for homing, save a few bytes 2016-07-06 16:21:51 -07:00
Scott Lahteine
d0b29cabf3 Don't re-home X and Y if you quick homed 2016-07-06 13:46:06 -07:00
Scott Lahteine
e0a6b978f5 Don't do_probe_raise with MIN_Z_HEIGHT_FOR_HOMING 2016-07-06 13:46:05 -07:00
Scott Lahteine
7735ec5e7a Merge pull request #4223 from thinkyhead/rc_rename_heatup
Change cancel_heatup to wait_for_heatup
2016-07-06 11:25:44 -07:00
Scott Lahteine
160a2be117 Change cancel_heatup to wait_for_heatup 2016-07-06 09:17:50 -07:00
AnHardt
16c83d203b Make use of the good features of a sled probe for all probes.
Move and extend axis_unhomed test to deploy/stow_z_probe().
Move and extend position store/restore to deploy/stow_z_probe().

Now all kinds of probes can use the 'E' parameter in G29/M48.
Allen key probes can be used now for grid and 3-point levelling.

Deploying the Allen Key probe uses big moves in z direction.
Too dangerous for an unhomed z-axis.
Throw a compile time error when we try to configure an
Allen Key probe homing to z-min and having no other z-min-endstop.
2016-07-06 04:11:04 +02:00
AnHardt
8555816a11 Generalize and simplify 'triggered when stowed test`
The `PROBE_IS_TRIGGERED_WHEN_STOWED_TEST` is able to detect if a probe is
successfully deployed/stowed.
It was part of the Allen Key probes code only.
Now the function is generally available.

Currently this test is compulsory for Allen Key probes to not alter the used behaviour
If you want to add the test for an other type of probe simply add
```
#define PROBE_IS_TRIGGERED_WHEN_STOWED_TEST
```
to your config.
2016-07-06 03:56:17 +02:00
AnHardt
5126cce7fd Move Allen Key probe move scripts to their own functions
There was an hidden extra move after the scripts. This is configurable now.
Added the extra moves to the relevant configs.
2016-07-06 03:46:40 +02:00
AnHardt
7d063c111c Add a optional feedrate parameter to do_blocking_move()
Add a optional feedrate parameter to `do_blocking_move()` and its companions.
2016-07-06 03:46:34 +02:00
Scott Lahteine
b114b6a0b3 Save 152 bytes using uint8_t for command indices 2016-07-05 16:29:28 -07:00
Scott Lahteine
0d4ff0c48b Allow the queue to be cleared from within commands 2016-07-05 16:25:20 -07:00
Scott Lahteine
c450851401 Merge pull request #4209 from AnHardt/too-high-G28
Make raise for probe deploy relative in homeaxis()
2016-07-05 11:07:42 -07:00
AnHardt
f799f18388 MBL typo 2016-07-05 18:19:53 +02:00
AnHardt
8b02e68cb6 Make raise for probe deploy relative in homeaxis()
Make raise for probe deploy relative in homeaxis()
by setting `current_position[axis]` to zero later.
2016-07-05 10:42:33 +02:00
Scott Lahteine
e48502866b Merge pull request #3611 from alephobjects/M108_cancel_heatup
Introduce M108 cancel wait for heatup/cooldown of the hotend and bed
2016-07-04 01:19:31 -07:00
Scott Lahteine
d70197f514 Merge pull request #4204 from thinkyhead/rc_fix_gcode_t_position
Additional patches for gcode_T position change
2016-07-04 01:16:22 -07:00
Scott Lahteine
869b517589 Merge pull request #4205 from thinkyhead/rc_fixup_unit_references
References to millimeters in code comments need an update
2016-07-04 01:15:34 -07:00
Scott Lahteine
e104b91ea6 References to millimeters in code comments need an update 2016-07-03 20:13:29 -07:00
AnHardt
ff91d28a3a Remove wants_to_cool warning
Remove wants_to_cool warning
2016-07-04 03:12:11 +02:00
Scott Lahteine
c9e536cf87 Additional patches for gcode_T position change 2016-07-03 18:11:02 -07:00
Scott Lahteine
f31af61ee2 Fix position adjustment with gcode_T and MBL 2016-07-03 17:44:04 -07:00
lrpirlet
9b42c6b44b apply correction when swtiching from MBL to physical in G28 X 2016-07-03 21:43:42 +02:00
Petr Zahradnik
43ff0ce35f Rewritten FILAMENT_CHANGE_ENABLE feature 2016-07-02 15:34:33 -07:00
AnHardt
cb1b31f69b Unconditional do_probe_raise() in probe_pt()
If Z_RAISE_BETWEEN_PROBINGS is null or undefined the probe is currently not raised by home_offset[Z_AXIS] and zprobe_zoffset.
But when different from 0 is.

If an undefined Z_RAISE_BETWEEN_PROBINGS expands to 0 (and it does) this is the solution.


A similar asymmetry exists with the newly introduced 'short-cut' in G28 - but its the rise before anything is probed - so should not make a difference.
2016-07-01 15:28:41 +02:00
Scott Lahteine
7ef7843fd4 Merge pull request #4181 from thinkyhead/rc_rename_a_move_func
Do interpolated moves for Allen Key deploy/stow
2016-06-30 16:30:09 -07:00
Scott Lahteine
da6b0dab5f Use prepare_move_to_destination for Allen Key deploy/stow 2016-06-30 16:09:43 -07:00
Scott Lahteine
c42f8fb8dd Rename some movement sub-functions 2016-06-30 15:50:00 -07:00
Scott Lahteine
5e14a528dd Always wait for cooling in M109/M190, break at low temp or if cooling stalls 2016-06-29 14:07:54 -07:00
Scott Lahteine
2e96276bf4 More debug message cleanup 2016-06-27 20:36:19 -07:00
Scott Lahteine
dc2c0e5e24 Simpler debug output for deploy/stow 2016-06-27 20:36:18 -07:00
Scott Lahteine
bd491818d6 Reduce storage requirements for strings, make some PGM 2016-06-27 20:36:18 -07:00
AnHardt
e480ee0054 Further cleanup of G28 for probes 2016-06-27 20:19:51 -07:00
AnHardt
39883d03fc universalize axis_unhomed_error() 2016-06-27 20:19:51 -07:00
AnHardt
e616093d4c Simplify dock_sled()
`dock_sled()` is never called with offset parameter - remove it.
We move x only - so only that needs to be homed. Consequence is - we can home to z-min now with a sled probe!
Feedrates are set and restored in `do_blocking_move()`.
We already checked if the probe is deployed/stowed in deploy/stow_probe.
```
if (z_loc < _Z_RAISE_PROBE_DEPLOY_STOW + 5) z_loc = _Z_RAISE_PROBE_DEPLOY_STOW;
```
makes no sense - remove.
Now the raise is the same for deploy/stow -> move before the if.
Replace the if with a ternary.
Instead writing LOW/HIGH use the boolean `stow` we already have.

There is no reason for not using the sled probe in G29/M48 with 'E'.
It takes a while but works. (tested!)
2016-06-27 20:19:51 -07:00
Scott Lahteine
829c92f1ba Use Z_RAISE_BETWEEN_PROBINGS with MBL 2016-06-26 15:39:11 -07:00
Scott Lahteine
eb1755208f Merge pull request #4153 from thinkyhead/rc_probe_raise_options
Combine Z raise before/after options
2016-06-26 15:30:08 -07:00
Scott Lahteine
10da7ac86c Combine Z raise before/after options 2016-06-26 13:56:30 -07:00
Scott Lahteine
3fa631130f Ensure a minimum height before XY move in probe_pt 2016-06-25 19:19:31 -07:00
Scott Lahteine
ca184d3d72 Merge pull request #4147 from thinkyhead/rc_fix_M48_raise
Fix debug output in probe_pt
2016-06-25 18:15:33 -07:00
Scott Lahteine
b4161cbd98 Fix debug output in probe_pt 2016-06-25 17:59:03 -07:00
Edward Patel
da88b00585 MBL: Add support for max z endstop
See https://github.com/MarlinFirmware/Marlin/issues/4088
2016-06-25 21:58:02 +02:00
Scott Lahteine
7de7552069 Merge pull request #4133 from MagoKimbra/Single_home_axis_delta
Single home Axis Delta need simple sync_plan_position
2016-06-23 21:14:22 -07:00
Scott Lahteine
15a6b49f37 Simplified probe_pt (in G30) 2016-06-23 20:25:46 -07:00
Scott Lahteine
6a7045b9bf Remove clean_up_after_endstop_move 2016-06-23 20:23:19 -07:00
Scott Lahteine
2a4f866561 Simplified probe_pt (in G29) 2016-06-23 20:22:28 -07:00
Scott Lahteine
89a2aa026b Simplified probe_pt (in M48) 2016-06-23 19:22:45 -07:00
Scott Lahteine
f8530c5d1f Simplified probe_pt function (G28 grid) 2016-06-23 19:09:32 -07:00
Scott Lahteine
c376c08042 Simplified probe_pt function (part 1) 2016-06-23 19:00:29 -07:00
Scott Lahteine
9a71b7f8ad Fix debug message for 3-point leveling 2016-06-23 18:17:31 -07:00
Scott Lahteine
550c03a5a9 Drop raise_z_after_probing function 2016-06-23 18:11:54 -07:00
Scott Lahteine
bb38c816af Always raise in deploy_z_probe / stow_z_probe 2016-06-23 18:00:20 -07:00
Scott Lahteine
68f3350050 Cleanup M401 / M402 2016-06-23 17:04:41 -07:00
Scott Lahteine
3afda99adf Regular handlers for G31 / G32 2016-06-23 17:04:13 -07:00
Scott Lahteine
6803c8e37e Move Z up before, or down after XY, for "blocking move" 2016-06-23 15:50:13 -07:00
MagoKimbra
570f3bbc07 Single home Axis Delta need simple sync_plan_position 2016-06-23 23:09:47 +02:00
Scott Lahteine
7b2fadd598 Apply some fixes from Andreas
Derived from
https://github.com/AnHardt/Marlin/commit/6e8ede8c694fa4d9e3c769840b09d56
7f8d8e0dd
2016-06-22 17:35:59 -07:00
Scott Lahteine
bd01592816 Goodbye MECHANICAL_PROBE 2016-06-22 17:13:33 -07:00
Scott Lahteine
2640d13a9f Simplify initial raise in M48 2016-06-22 16:53:04 -07:00
Scott Lahteine
3763d45656 Return Z position in run_z_probe 2016-06-22 16:52:32 -07:00
Scott Lahteine
1f48b5c30f Pass a raise to probe_pt, not a Z position 2016-06-22 16:40:21 -07:00
Scott Lahteine
6fdd5ba246 Save and restore feedrate in more places 2016-06-22 16:40:20 -07:00
Scott Lahteine
fe173c2bc6 Generalized probe raise, use for after probing 2016-06-22 14:44:30 -07:00
Scott Lahteine
7da3080761 Simpler cleanup in G28 / G29 2016-06-22 14:44:30 -07:00
Scott Lahteine
15229d988b Fix compile error for bed matrix in M48 2016-06-22 14:04:46 -07:00
Scott Lahteine
c01352cbd5 Add a dependency for z servo macros 2016-06-22 14:04:23 -07:00
Scott Lahteine
c3794bd695 Add HAS_PROBING_PROCEDURE conditional 2016-06-22 14:03:22 -07:00
Scott Lahteine
bb9c67b4b5 Tweak some feedrate vars 2016-06-22 03:27:31 -07:00
Scott Lahteine
5158bd6e93 Screen out G29 E for sled and allen key, allow single probe 2016-06-22 03:20:33 -07:00
Scott Lahteine
ccae92588d Cleanup debug in G28 and G29 2016-06-22 03:20:33 -07:00
Scott Lahteine
b4a9d2366c Use a macro for kinematic sync_plan_position 2016-06-22 03:20:33 -07:00
Scott Lahteine
bfccf26294 Use sync_plan_position_delta where needed 2016-06-22 03:20:33 -07:00
Scott Lahteine
a6b8c67df4 Move probe deploy after setup call in G29 2016-06-22 03:20:33 -07:00
Scott Lahteine
e69916d1bd Split up endstop_move functions 2016-06-22 03:20:33 -07:00
Scott Lahteine
0e18a4897b Simpler handling of sled/allen-key in probe_pt 2016-06-22 03:20:33 -07:00
Scott Lahteine
1a92e2ef18 Comment on run_z_probe 2016-06-22 03:20:33 -07:00
Scott Lahteine
68e0e5855e For all probes, at the end of G29 simply raise and stow 2016-06-22 03:20:33 -07:00
Scott Lahteine
c3023f8cc5 Make M401/M402 available with HAS_BED_PROBE 2016-06-22 03:20:33 -07:00
Scott Lahteine
9f0c255c69 Show uncorrected position in set_bed_level_equation_3pts 2016-06-22 03:20:33 -07:00
Scott Lahteine
07298ac992 Initialize current_position to home_offset on boot 2016-06-22 03:20:33 -07:00
Scott Lahteine
d50539583a Make XY_PROBE_SPEED a general probe option 2016-06-22 03:04:47 -07:00
Scott Lahteine
2798499b71 XY_TRAVEL_SPEED => XY_PROBE_SPEED 2016-06-22 02:45:25 -07:00
Scott Lahteine
88dc543584 Add a macro for XY_TRAVEL_FEEDRATE 2016-06-22 02:23:50 -07:00
Scott Lahteine
3996242e9d Allow Z_MIN_PROBE_REPEATABILITY_TEST solo 2016-06-21 01:56:40 -07:00
Scott Lahteine
26a9cd0b08 Move run_z_probe to earlier block 2016-06-21 01:25:23 -07:00
Scott Lahteine
7f8a2025af Move raise_z_after_probing into earlier block 2016-06-21 01:03:40 -07:00
Scott Lahteine
2530371516 Always disable probe at the end of G29 2016-06-20 16:40:44 -07:00
Scott Lahteine
6aba98e470 Comment on setup_for_endstop_move 2016-06-20 16:40:44 -07:00
Scott Lahteine
04e88d008e Clear up ordering in G30 2016-06-20 16:40:44 -07:00
Scott Lahteine
ed75b0ea11 Make clean_up function available for probes 2016-06-20 16:28:45 -07:00
Scott Lahteine
51d52cb52a Make run_z_probe available for any bed probe 2016-06-20 16:02:36 -07:00
Scott Lahteine
f6b09cf465 Always use deploy/stow for dock_sled 2016-06-20 15:51:01 -07:00
Scott Lahteine
3b457c2dd3 Use deploy/stow with FIX_MOUNTED_PROBE too 2016-06-20 15:25:01 -07:00
Scott Lahteine
7e9d4a68d4 Always raise Z (if needed) for servo deploy/stow 2016-06-19 20:17:13 -07:00
Scott Lahteine
9beb3f2f5e Merge pull request #4097 from thinkyhead/rc_fil_runout_cleanup
FIL_RUNOUT_INVERTING false by default
2016-06-19 19:46:14 -07:00
Scott Lahteine
f215b30932 Merge pull request #4093 from thinkyhead/rc_probe_without_abl
Make Z Probe options independent of ABL
2016-06-19 19:44:25 -07:00
Scott Lahteine
2fd2301928 FILRUNOUT => FIL_RUNOUT 2016-06-19 19:25:26 -07:00
Scott Lahteine
de12228758 Make Z Probe options independent of ABL 2016-06-19 18:47:27 -07:00
Scott Lahteine
add0032820 Improve FILAMENT_RUNOUT_SENSOR, FILRUNOUT_PIN 2016-06-19 18:13:33 -07:00
Scott Lahteine
400e13d136 Output a message for SD read errors 2016-06-19 17:14:56 -07:00
Roxy-3D
96b8bcca84 Merge pull request #4081 from thinkyhead/rc_tweaky_m48_tweaks
Cleanup of M48
2016-06-18 22:21:16 -05:00
Scott Lahteine
b7e3c1bbc4 Tweak M48 output conditions 2016-06-18 16:17:53 -07:00
Scott Lahteine
1dad912b03 Adjust M48 raise / move handling 2016-06-18 15:38:24 -07:00
Scott Lahteine
46d3ef2223 Simplify sample_set probe_pt call in M48 2016-06-18 15:38:23 -07:00
Scott Lahteine
a647b05f82 Shrink some debug code in G28 2016-06-18 15:38:23 -07:00
Scott Lahteine
4edf813bde Just-in-time declaration style in M48 2016-06-18 15:38:23 -07:00
Juan Ricardo Gomez Anaya
c475291e19 Fix M851
Minor change missing in the process of standardize the gcode M851
2016-06-18 15:19:07 -07:00
Scott Lahteine
4e860babbc Allow setting xy_travel_speed for delta leveling also 2016-06-18 01:40:49 -07:00
Scott Lahteine
d36d4edd80 Tweak partial homing code 2016-06-18 01:16:50 -07:00
Scott Lahteine
d3a05de96e Save and restore feedrate in probe functions 2016-06-18 01:16:26 -07:00
Scott Lahteine
defcacc1a9 Delete some obsolete Z servo macros 2016-06-17 18:49:17 -07:00
Scott Lahteine
3a150f07c2 Merge pull request #4073 from thinkyhead/rc_temp_mystery
Minor tweaks to M109 / M190
2016-06-17 17:49:50 -07:00
Scott Lahteine
bd4ec727e7 Merge pull request #4066 from thinkyhead/rc_M851_with_probe
Make M851 standard with a bed probe
2016-06-17 17:32:55 -07:00
Scott Lahteine
692a6e7c91 Merge pull request #4065 from thinkyhead/rc_goodbye_xy_servos
Remove support for XY servo endstops
2016-06-17 17:32:08 -07:00
Scott Lahteine
de177ba6c9 Minor tweaks to M109 / M190 2016-06-17 17:26:21 -07:00
Scott Lahteine
1000563d80 Make M851 standard with a bed probe 2016-06-17 15:19:42 -07:00
Scott Lahteine
f66a194159 Merge pull request #4062 from jbrazio/bugfix/compiler-warnings
Fixes misc gcc warnings
2016-06-17 14:23:28 -07:00
Scott Lahteine
1bed392c68 HAS_Z_ENDSTOP_SERVO => HAS_Z_SERVO_ENDSTOP 2016-06-17 14:20:17 -07:00
Scott Lahteine
47ce810f52 Remove support for XY servo endstops 2016-06-17 14:19:17 -07:00
João Brázio
d1e5dc6319
Fixes misc gcc warnings 2016-06-17 20:24:24 +01:00
Scott Lahteine
ef3bef6b9e Fix feedrate in gcode_T (max_feedrate is mm/s) 2016-06-16 16:03:14 -07:00
MagoKimbra
008d0637dd Fix gcode_T 2016-06-16 09:05:36 +02:00
Scott Lahteine
da90bbe0eb Merge pull request #4010 from thinkyhead/rc_toolchange_adjust
Fixup position adjustment on toolchange
2016-06-15 21:10:33 -07:00
Scott Lahteine
4b93989a77 MBL Z adjustment on toolchange 2016-06-15 20:49:36 -07:00
Scott Lahteine
9c800d1f8c Position adjustment for bed leveling 2016-06-15 20:49:36 -07:00
esenapaj
44f091a413 Fix for the PR #4023(Add macros to move servos)
・Add missing ')'
2016-06-15 22:34:55 +09:00
Scott Lahteine
52ac2a62ee Merge pull request #4013 from thinkyhead/rc_toolchange_no_move
Use "Tn S1" to change tools without moving
2016-06-14 20:13:01 -07:00
Scott Lahteine
d2a00b74e3 Merge pull request #4004 from thinkyhead/rc_feedrate_in_gcode_T
Use linear feedrate in gcode_T, not volumetric
2016-06-14 20:10:08 -07:00
Scott Lahteine
8d8180e028 Parse M905 args in Marlin_main.cpp 2016-06-13 19:25:28 -07:00
Scott Lahteine
2b340f5acb patch LIN_ADVANCE to use code_value_float 2016-06-13 18:54:25 -07:00
Scott Lahteine
b708196770 Merge pull request #4032 from AnHardt/bootscreen-delay
Show bootscreen later
2016-06-13 18:27:05 -07:00
Scott Lahteine
587de1b6b6 Merge pull request #3676 from thinkyhead/rc_lin_advance_feature
Advance extrusion algorithm – LIN_ADVANCE
2016-06-13 18:04:58 -07:00
AnHardt
b4fedec0d1 Show bootscreen later
Init display and show bootscreen later, but init display in `kill()`
to init outputs before the bootscreen delays but being able to display
kill errors.
2016-06-14 01:59:50 +02:00
Scott Lahteine
4fbe818163 Add macros to move servos 2016-06-12 15:38:30 -07:00
Scott Lahteine
7fb69e24fb Use "Tn S1" to change tools without moving 2016-06-11 15:58:45 -07:00
Scott Lahteine
b75e648f2c Clarify names of prepare_move functions 2016-06-11 15:32:49 -07:00
Scott Lahteine
0e2bfd0769 Use linear feedrate in gcode_T, not volumetric 2016-06-10 18:27:01 -07:00
Scott Lahteine
6d62a4ffc8 Patch LIN_ADVANCE for style and forward-compatibility 2016-06-09 21:03:27 -07:00
Sebastianv650
fb8e880734 Add LIN_ADVANCE 2016-06-09 21:03:27 -07:00
Scott Lahteine
e2d4919c01 Merge pull request #3991 from thinkyhead/rc_axis_units
Rename some vars to clarify their relationship to acceleration
2016-06-09 20:57:01 -07:00
João Brázio
5b5aa1572b Non-blocking buzzer 2016-06-09 20:20:05 -07:00
Scott Lahteine
72c6f2923f axis_steps_per_unit => axis_steps_per_mm 2016-06-09 17:04:51 -07:00
Scott Lahteine
cb4704e07a Rename some planner acceleration vars
- `per_sq_second` => `per_s2`
- `per_sqr_second` => `per_s2`
- `axis_steps_per_sqr_second` => `max_acceleration_steps_per_s2`
2016-06-09 17:04:50 -07:00
Scott Lahteine
4980ecc1f7 Smaller binary using inline gcode argument getters 2016-06-08 17:03:28 -07:00
Reid Rankin
16212432c9 G20/21 and M149 support, and code_value() refactor
This is an update of MarlinDev PR #196.

G20/21: support for switching input units between millimeters and
inches.
M149: support for changing input temperature units.

In support of these changes, code_value() and code_value_short() are
replaced with an array of functions which handle converting to the
proper types and/or units.
2016-06-08 16:51:10 -07:00
Scott Lahteine
cca047424d MBL: cel => cell 2016-06-07 19:10:39 -07:00
Scott Lahteine
43947072d5 Merge pull request #3895 from thinkyhead/rc_singlenozzle_part_2
SINGLENOZZLE: EXTRUDERS versus HOTENDS
2016-06-04 15:23:17 -07:00
Scott Lahteine
d7e4e8e9be Fix a typo in #3955 2016-06-04 02:09:58 -07:00
Scott Lahteine
c2362c1b3c Apply Marlin coding standards to MBL class 2016-06-03 21:43:32 -07:00
Edward Patel
c06de0f097 MBL: Added keeping MBL active when homing single axises for #3750 2016-06-03 21:42:29 -07:00
Scott Lahteine
f2fb66c00d With SINGLENOZZLE only set temperature for the active tool 2016-06-03 17:38:03 -07:00
Scott Lahteine
cd441ce652 SINGLENOZZLE: EXTRUDERS versus HOTENDS 2016-06-03 17:38:03 -07:00
Scott Lahteine
32f8300cc6 Merge pull request #3944 from thinkyhead/rc_eboston_lcd_contrast
Improved LCD contrast handling
2016-06-03 17:08:41 -07:00
Scott Lahteine
4e13cd3f35 Merge pull request #3955 from MagoKimbra/RCBugFix
Fix M428 width DELTA & SCARA
2016-06-03 15:50:37 -07:00
Scott Lahteine
8529122af1 Merge pull request #3946 from thinkyhead/rc_g28_servo_raise_before_stow
Raise the servo probe before stow outside ABL context
2016-06-03 15:45:36 -07:00
MagoKimbra
f499be084a Fix M428 width DELTA & SCARA 2016-06-03 23:23:23 +02:00
Scott Lahteine
664b299a51 This fix is not DELTA compatible 2016-06-02 17:16:19 -07:00
Scott Lahteine
064efb20e0 Also call clear_command_queue for lcd_sdcard_stop 2016-06-02 17:16:19 -07:00
Scott Lahteine
6277395e1e set_current_position_from_planner() after stepper.quick_stop() 2016-06-02 17:16:19 -07:00
Scott Lahteine
381bc6f0b0 set_position => set_position_mm 2016-06-02 17:16:19 -07:00
Scott Lahteine
9eecb4404b Make raise_z_after_probing null sometimes 2016-06-02 16:56:49 -07:00
Scott Lahteine
b3a37b493d Patch G28 servo stow to use Conditionals, raise_z_after_probing 2016-06-02 16:56:49 -07:00
Scott Lahteine
efa7209acf Improved LCD contrast handling
Based on MarlinFirmware/MarlinDev#200 from @eboston
2016-06-02 16:17:34 -07:00
lrpirlet
3aefa04386 Raise the servo probe before stow outside ABL context 2016-06-01 21:53:45 +02:00
Scott Lahteine
d698c89971 Fix bad movement in gcode_T when switching 2016-05-31 19:14:33 -07:00
Scott Lahteine
1a01a44a94 Merge pull request #3936 from thinkyhead/rc_sav_mk1
Support for SAV_3DGLCD OLED LCD controller
2016-05-31 18:46:25 -07:00
Scott Lahteine
bd97bbc52a Make HAS_LCD_CONTRAST a boolean flag 2016-05-31 11:47:02 -07:00
Scott Lahteine
55ef04a566 Need to call dac_init() in setup() for DAC_STEPPER_CURRENT
As reported by https://github.com/MarlinFirmware/Marlin/pull/3182#issuecomment-222595488
2016-05-30 23:35:06 -07:00
Scott Lahteine
360adc6a3b Small reduction in M421 code 2016-05-23 14:25:42 -07:00
Scott Lahteine
a4ed988c60 Two index finding functions for MBL 2016-05-23 14:25:42 -07:00
Scott Lahteine
cadf441059 Merge pull request #3798 from AnHardt/extend-M421
Extend M421 with I and J parameters
2016-05-20 16:17:23 -07:00
AnHardt
f5a036510f Extend M421 with I and J parameters
Extend M421 with I and J parameters
2016-05-21 00:18:09 +02:00
Edward Patel
c7d90dc5ec Add option to configure G28 all axis resting position for MBL 2016-05-20 11:52:27 -07:00
Scott Lahteine
8218558953 Update comments, rename next_ping_ms, followup to #3797 2016-05-19 16:44:57 -07:00
AnHardt
e761bdbb4b Remove SF_ARC_FIX from G5 (Cubic B-spline)
Remove SF_ARC_FIX from G5 (Cubic B-spline).
SF_ARC_FIX is a fix for G2/G3 (arcs) where Skeinforge always produced relative instead of absolute coordinates for the endpoint of an arc.
It's very unlikely this is also a problem with Cubic B-splines. More likely is copying from the G2/G3 code.
2016-05-19 21:00:12 +02:00
AnHardt
2207001333 No compromises for the manage_heater()
No compromises for the manage_heater(). manage_heater() will return immediately when there is nothing to do, but needs a constant detaT to work proper.
Calling idle() only every 200ms results in a display update every ~2 seconds - that should be enough.
For the other functionalities in idle() and manage_inactivity() 200ms is a lot but hopefully works.
2016-05-19 20:52:11 +02:00
João Brázio
e6effb8f35
Implements S1 argument in M999 2016-05-19 00:13:33 +01:00
Scott Lahteine
4041508ffb Function decl. in headers don't need "extern" 2016-05-17 18:35:01 -07:00
Scott Lahteine
d66e53c42b Merge pull request #3782 from thinkyhead/rc_home_z_before_g29
Require homing of Z before G29
2016-05-17 17:53:56 -07:00
Scott Lahteine
552516ddf5 Merge pull request #3781 from AnHardt/minor-delta-segmenting-speedup
Minor DELTA segmentation speedup
2016-05-17 17:17:38 -07:00
Scott Lahteine
a28970784c XYZ unhomed 2016-05-17 17:02:53 -07:00
Scott Lahteine
a9926b71a4 Require homing of Z before G29 2016-05-17 16:57:12 -07:00
AnHardt
41e9569dbc Minor DELTA segmentation speedup
Minor DELTA segmentation speedup by pulling calculations out of the loop.
2016-05-18 01:49:30 +02:00
Scott Lahteine
3016dfe484 Merge pull request #3744 from thinkyhead/rc_bezier_curves
Add BEZIER_CURVE_SUPPORT — G5 command
2016-05-17 13:57:38 -07:00
Scott Lahteine
d0ac4541d3 Merge pull request #3775 from jbrazio/bugfix/followup-3770
G29: Report final position back to host when using MBL
2016-05-17 13:55:26 -07:00
João Brázio
b6a3aef297
G29: Report final position back to host when using MBL 2016-05-17 01:27:59 +01:00
esenapaj
95f30529a6 Add stowing process for MECHANICAL_PROBE 2016-05-16 18:12:10 +09:00
esenapaj
e2b87f6c85 Separate Z_PROBE_ALLEN_KEY from MECHANICAL_PROBE 2016-05-16 18:12:10 +09:00
Scott Lahteine
754b0152f5 Fix MBL zigzag calls 2016-05-15 12:35:01 -07:00
Scott Lahteine
13175ce7da Fix error checking in M421 2016-05-14 17:12:44 -07:00
João Brázio
8a18c52002 Adds an option to disable print job timer auto start 2016-05-14 15:22:44 -07:00
João Brázio
a79267217b M78 now allows stats reset using the S78 argument 2016-05-14 15:22:44 -07:00
Scott Lahteine
a713043acd Merge pull request #3749 from esenapaj/patch-3
Enclose all #error strings by double-quotes
2016-05-14 15:01:56 -07:00
Scott Lahteine
3cfea3ff12 Merge pull request #3752 from AnHardt/fix-FIX_MOUNTED_PROBE
G29 missing FIX_MOUNTED_PROBE condition
2016-05-14 15:00:42 -07:00
Scott Lahteine
ddac17a195 Add BEZIER_CURVE_SUPPORT (G5 XYZEFIJPQ) 2016-05-14 14:52:08 -07:00
AnHardt
8a4376d51f Idle during long arcs
Idle during long arcs
to prevent from watchdog resets during high segmented fast arcs.
2016-05-14 00:29:13 +02:00
esenapaj
888443ca1e Enclose all #error strings with apostrophes 2016-05-13 21:10:23 +09:00
AnHardt
b74af78736 Make arc support (G2/G3) configurable
Saves about 2669 bytes when deactivated. (About 1% for a AT2560, about __4%__ for a AT644!)
2016-05-13 13:27:45 +02:00
AnHardt
aef2559bd8 fix-FIX_MOUNTED_PROBE
Add a forgotten condition
2016-05-13 12:07:17 +02:00
Scott Lahteine
aaeadf0cbd If no "B" parameter given, get 1 byte 2016-05-11 15:30:08 -07:00
Scott Lahteine
a6d594665b Print an error on bad i2c request
Reference: https://github.com/MarlinFirmware/Marlin/pull/3713#issuecomment-218333678
2016-05-11 15:30:02 -07:00
Scott Lahteine
56dd31ea3c Use code_value_long for potentially large values
Addressing #3711
2016-05-10 09:15:31 -07:00
Scott Lahteine
96b71e62c0 Fix dipping on DELTA robots during G29
- Addressing #3689, et. al.
2016-05-08 18:28:46 -07:00